A hybrid FIA/HPLC system incorporating monolithic column chromatography

被引:37
作者
Adcock, Jacqui L.
Francis, Paul S. [1 ]
Agg, Kent M.
Marshall, Graham D.
Barnett, Neil W.
机构
[1] Deakin Univ, Sch Life & Environm Sci, Geelong, Vic 3217, Australia
[2] GlobalFIA, Fox Isl, WA 98333 USA
基金
澳大利亚研究理事会;
关键词
flow injection analysis; gradient elution; monolithic column chromatography; chemiluminescence detection; neurotransmitter metabolites;
D O I
10.1016/j.aca.2007.03.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have combined the generation of solvent gradients using milliGAT pumps, chromatographic separations with monolithic columns and chemiluminescence detection in an instrument manifold that approaches the automation and separation efficiency of HPLC, whilst maintaining the positive attributes of flow injection analysis (FIA), such as manifold versatility, speed of analysis and portability. As preliminary demonstrations of this hybrid FIA/HPLC system, we have determined six opiate alkaloids (morphine, pseudomorphine, codeine, oripavine, ethylmorphine and thebaine) and four biogenic amines (vanilmandelic acid, serotonin, 5 -hydroxyindole - 3 -acetic acid and homovanillic acid) in human urine, using tris(2,2'-bipyridyl)ruthenium(III) and acidic potassium permanganate chemiluminescence detection. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 28 条
[1]   Determination of selected neurotransmitter metabolites using monolithic column chromatography coupled with chemiluminescence detection [J].
Adcock, JL ;
Barnett, NW ;
Costin, JW ;
Francis, PS ;
Lewis, SW .
TALANTA, 2005, 67 (03) :585-589
[2]   Determination of 5-hydroxytryptamine (serotonin) and related indoles by flow injection analysis with acidic potassium permanganate chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :131-139
[3]   Some observations on the chemiluminescent reactions of tris(2,2'-bipyridyl)ruthenium(III) with certain Papaver somniferum alkaloids and their derivatives [J].
Barnett, NW ;
Gerardi, RD ;
Hampson, DL ;
Russell, RA .
ANALYTICAL COMMUNICATIONS, 1996, 33 (08) :255-260
[4]   Applications of silica-based monolithic HPLC columns [J].
Cabrera, K .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (10-11) :843-852
[5]   Fast simultaneous spectrophotometric determination of naphazoline nitrate and methylparaben by sequential injection chromatography [J].
Chocholous, Petr ;
Satinsky, Dalibor ;
Solich, Petr .
TALANTA, 2006, 70 (02) :408-413
[6]   Selective determination of amino acids using flow injection analysis coupled with chemiluminescence detection [J].
Costin, JW ;
Francis, PS ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 2003, 480 (01) :67-77
[7]   RAPID SEQUENTIAL DETERMINATION OF CHROMIUM(III) - CHROMIUM(VI) BY FLOW-INJECTION ANALYSIS - INDUCTIVELY COUPLED PLASMA ATOMIC-EMISSION SPECTROMETRY [J].
COX, AG ;
COOK, IG ;
MCLEOD, CW .
ANALYST, 1985, 110 (04) :331-333
[8]  
Fang Z., 1993, FLOW INJECTION SEPAR
[9]   Flow analysis based on a pulsed flow of solution: theory, instrumentation and applications [J].
Francis, PS ;
Lewis, SW ;
Lim, KF ;
Carlsson, K ;
Karlberg, B .
TALANTA, 2002, 58 (06) :1029-1042
[10]   Coupling of monolithic columns with sequential injection technique -: A new separation approach in flow methods [J].
Huclová, J ;
Satínsky, D ;
Karlícek, R .
ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) :133-140