The light-addressable potentiometric sensor for multi-ion sensing and imaging

被引:131
作者
Yoshinobu, T
Iwasaki, H
Ui, Y
Furuichi, K
Ermolenko, Y
Mourzina, Y
Wagner, T
Näther, N
Schöning, MJ
机构
[1] Osaka Univ, Inst Sci & Ind Res, Ibaraki 5670047, Japan
[2] St Petersburg State Univ, Fac Chem, St Petersburg 199034, Russia
[3] Res Ctr Julich, Inst Thin Films & Interfaces, D-52425 Julich, Germany
[4] Univ Appl Sci Aachen, D-52428 Julich, Germany
关键词
chemical sensor; light-addressable potentiometric sensor; chemical imaging sensor; semi conductor; microfluidic device;
D O I
10.1016/j.ymeth.2005.05.020
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
The light-addressable potentiometric sensor (LAPS) is a semiconductor-based chemical sensor with an electrolyte-insulator-semiconductor structure. The LAPS can have many measuring points integrated on the sensing surface, which are individually accessed by a light beam. By modifying the measuring points with different materials, a single sensor plate can be used as a multi-analyte sensor. In this paper, instrumentation and application of LAPS to multi-ion sensing and imaging are described. As a new application of LAPS, potentiometric imaging of a microfluidic channel is proposed. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:94 / 102
页数:9
相关论文
共 53 条
[1]
Bae SK, 2003, IEICE T ELECTRON, VE86C, P1109
[3]
The double K+/Ca2+ sensor based on laser scanned silicon transducer (LSST) for multi-component analysis [J].
Ermolenko, Y ;
Yoshinobu, T ;
Mourzina, Y ;
Furuichi, K ;
Levichev, S ;
Schöning, MJ ;
Vlasov, Y ;
Iwasaki, H .
TALANTA, 2003, 59 (04) :785-795
[4]
Photocurable membranes for ion-selective light-addressable potentiometric sensor [J].
Ermolenko, Y ;
Yoshinobu, T ;
Mourzina, Y ;
Levichev, S ;
Furuichi, K ;
Vlasov, Y ;
Schöning, MJ ;
Iwasaki, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 85 (1-2) :79-85
[5]
Lithium sensor based on the laser scanning semiconductor transducer [J].
Ermolenko, Y ;
Yoshinobu, T ;
Mourzina, Y ;
Furuichi, K ;
Levichev, S ;
Vlasov, Y ;
Schöning, MJ ;
Iwasaki, H .
ANALYTICA CHIMICA ACTA, 2002, 459 (01) :1-9
[6]
Laser-scanned silicon transducer (LSST) as a multisensor system [J].
Ermolenko, YE ;
Yoshinobu, T ;
Mourzina, YG ;
Vlasov, YG ;
Schöning, MJ ;
Iwasaki, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 103 (1-2) :457-462
[7]
INTEGRATED MICRO MULTI ION SENSOR USING FIELD-EFFECT OF SEMICONDUCTOR [J].
ESASHI, M ;
MATSUO, T .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1978, 25 (02) :184-192
[8]
Comparison between a LAPS and an FET-based sensor for cell-metabolism detection [J].
Fanigliulo, A ;
Accossato, P ;
Adami, M ;
Lanzi, M ;
Martinoia, S ;
Paddeu, S ;
Marodi, MT ;
Rossi, A ;
Sartore, M ;
Grattarola, M ;
Nicolini, C .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 32 (01) :41-48
[9]
Investigation of the spatial resolution of the light-addressable potentiometric sensor [J].
George, M ;
Parak, WJ ;
Gerhardt, I ;
Moritz, W ;
Kaesen, F ;
Geiger, H ;
Eisele, I ;
Gaub, HE .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 86 (03) :187-196
[10]
Chemical microsensors based on chalcogenide glasses for the detection of cadmium ions in solution [J].
Guessous, A ;
Sarradin, J ;
Papet, P ;
Elkacemi, K ;
Belcadi, S ;
Pradel, A ;
Ribes, M .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 53 (1-2) :13-18