Potentiometric carbon paste electrodes for the determination of bismuth in some pharmaceutical preparations

被引:12
作者
Mostafa, Gamal Abdel-Hafeez [1 ]
Homoda, Atef Mohammed [1 ]
机构
[1] Natl Res Ctr, Appl Organ Chem Dept, Microanalyt Lab, Cairo, Egypt
关键词
D O I
10.1246/bcsj.81.257
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The construction and general performance characteristics of two novel potentiometric membrane sensors responsive to bismuth are described. The sensors are based on the use of ion-association complexes of tetraiodobismate(III) (TIB) anion with polyoxyethylene(10) octyl phenyl ether (1) and tris(1,10-phenanthroline)iron(II) (2) as exchange sites in a carbon paste matrix. The sensors show fast, stable, and near-Nernstian response for the mono-charged anion of tetraiodobismate(III) over the concentration range 1 x 10(-3)-1 x 10(-6) mol dm(-3) at 25 degrees C over the pH range 4.0-9.0 and 3.0-8.0 with an anionic slope of 51.5 +/- 0.5 and 53.0 +/- 0.4 per concentration decade for tetraiodobismate(III)-1 and -2 (sensor-1 and sensor-2), respectively. The lower detection limit was 4 x 10(-6) and 2 x 10(-6) mol dm(-3) with a response time of 20-40 s for sensor-1 and sensor-2 in the same order. The selectivity coefficients for bismuth relative to a number of interfering anions and iodide complexes of some metal ions were investigated. Direct potentiometric determination of 1-200 mu g cm(-3) of bismuth in aqueous solution showed an average recovery of 98.4% and a mean relative standard deviation of 1.5% at 80.0 mu g cm(-3). The determination of bismuth(III) in suppositories and ointment dosage form in the present study was comparable with the British pharmacopoeia method.
引用
收藏
页码:257 / 261
页数:5
相关论文
共 36 条
[1]   Gallamine-tetraphenylborate-modified carbon paste electrode for the potentiometric determination of gallamine triethiodide (Flaxedil) [J].
Abbas, MN ;
Mostafa, GAE .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (04) :819-826
[2]   New triiodomercurate-modified carbon paste electrode for the potentiometric determination of mercury [J].
Abbas, MN ;
Mostafa, GAE .
ANALYTICA CHIMICA ACTA, 2003, 478 (02) :329-335
[3]   A selective modified carbon paste electrode for determination of cyanide using tetra-3,4-pyridinoporphyrazinatocobalt(II) [J].
Abbaspour, A ;
Asadi, M ;
Ghaffarinejad, A ;
Safaei, E .
TALANTA, 2005, 66 (04) :931-936
[4]   SELECTIVE POTENTIOMETRIC DETERMINATION OF BI(III) WITH A COATED-WIRE ELECTRODE [J].
ALEXANDER, PW ;
JOSEPH, JP .
TALANTA, 1981, 28 (12) :931-934
[5]   Determination of bismuth in pharmaceutical products using liquid-liquid extraction in a flow injection system [J].
Alonso, A ;
Almendral, MJ ;
Báez, MD ;
Porras, MJ ;
Lávin, FL ;
de María, CG .
ANALYTICA CHIMICA ACTA, 2000, 408 (1-2) :129-133
[6]   Spectrophotometric determination of bismuth after extraction of benzyltributylammonium tetraiodobismuthate(III) [J].
Barakat, SA ;
Burns, DT .
ANALYTICA CHIMICA ACTA, 1997, 355 (2-3) :167-170
[7]   THE DETERMINATION OF BISMUTH IN SERUM AND URINE BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BERTHOLF, RL ;
RENOE, BW .
ANALYTICA CHIMICA ACTA, 1982, 139 (JUL) :287-295
[8]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[9]   Determination of bismuth in biological samples using on-line flow-injection microwave-assisted mineralization and precipitation/dissolution for electrothermal atomic absorption spectrometry [J].
Burguera, JL ;
Burguera, M ;
Rivas, C ;
Rondon, C ;
Carrero, P ;
Gallignani, M .
TALANTA, 1999, 48 (04) :885-893
[10]   Spectrophotometric determination of bismuth after extraction of tetrabutylammonium tetraiodobismuthate(III) with microcrystalline benzophenone [J].
Burns, DT ;
Tungkananuruk, N ;
Thuwasin, S .
ANALYTICA CHIMICA ACTA, 2000, 419 (01) :41-44