Fabricated aptamer-based electrochemical "signal-off" sensor of ochratoxin A

被引:198
作者
Kuang, Hua [1 ]
Chen, Wei [1 ]
Xu, Dinghua [1 ]
Xu, Liguang [1 ]
Zhu, Yingyue [1 ]
Liu, Liqiang [1 ]
Chu, Huaqin [1 ]
Peng, Chifang [1 ]
Xu, Chuanlai [1 ]
Zhu, Shuifang [1 ]
机构
[1] Jiangnan Univ, State Key Lab Food Sci & Technol, Sch Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Ultrasensitive; Toxin detection; Electrochemical detection; Aptamer; LINKED-IMMUNOSORBENT-ASSAY; IN-VITRO SELECTION; GOLD NANOPARTICLES; ULTRASENSITIVE DETECTION; SMALL MOLECULES; CHROMATOGRAPHY; AMPLIFICATION; BIOSENSOR; SEQUENCE; PLATFORM;
D O I
10.1016/j.bios.2010.06.058
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An ultrasensitive and rapid electrochemical platform for the specific detection of ochratoxin A (OTA) was developed. In this method, three single-stranded DNA molecules, including the aptamer, were immobilized on the surface of an electrode. Binding of the OTA target analyte to the aptamer changed the redox current of methylene blue (MB), which was used as the electrochemical probe, in a manner that was dependent on OTA concentration. With signal enhancement from gold nanoparticle-functionalized DNA, the sensitivity of this method for OTA was as low as 30 pg/mL, and the effective sensing range was from 0.1 to 20 ng/mL To investigate the sensing process, the conformational switch of the aptamer was studied by circular dichroism (CD), which confirmed the recognition of the aptamer by the target OTA. Given its sensitivity and rapid detection, we believe this approach has the potential to be a main technology for the detection of toxins in the field of food safety, and in other areas. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:710 / 716
页数:7
相关论文
共 48 条
  • [1] Evaluation of methods used to determine ochratoxin a in coffee beans
    Ahmed, N. E.
    Farag, M. M.
    Soliman, K. M.
    Abdel-Samed, A. K. M.
    Naguib, Kh. M.
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (23) : 9576 - 9580
  • [2] A novel electrochemical detection method for aptamer biosensors
    Bang, GS
    Cho, S
    Kim, BG
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 21 (06) : 863 - 870
  • [3] Sensitive ELISA test for determination of ochratoxin A
    Barna-Vetro, I
    Solti, L
    Teren, J
    Gyongyosi, A
    Szabo, E
    Wolfling, A
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1996, 44 (12) : 4071 - 4074
  • [4] DNA enzymes
    Breaker, RR
    [J]. NATURE BIOTECHNOLOGY, 1997, 15 (05) : 427 - 431
  • [5] PLASMA OCHRATOXIN A LEVELS IN 3 SWEDISH POPULATIONS SURVEYED USING AN ION-PAIR HPLC TECHNIQUE
    BREITHOLTZ, A
    OLSEN, M
    DAHLBACK, A
    HULT, K
    [J]. FOOD ADDITIVES AND CONTAMINANTS, 1991, 8 (02): : 183 - 192
  • [6] Rational design and performance testing of aptamer-based electrochemical biosensors for adenosine
    Chakraborty, Banani
    Jiang, Zhifeng
    Li, Yunchao
    Yu, Hua-Zhong
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 635 (02) : 75 - 82
  • [7] Automated and ultrasensitive detection of methyl-3-quinoxaline-2-carboxylic acid by using gold nanoparticles probes SIA-rt-PCR
    Chen, Wei
    Jiang, Yuan
    Ji, Baoqing
    Zhu, Changqin
    Liu, Liqiang
    Peng, Chifang
    Jin, M. Kim
    Qiao, Ruirui
    Jin, Zhengyu
    Wang, Libing
    Zhu, Shuifang
    Xu, Chuanlai
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (09) : 2858 - 2863
  • [8] Ultrasensitive immunoassay of 7-aminoclonazepam in human urine based on CdTe nanoparticle bioconjugations by fabricated microfluidic chip
    Chen, Wei
    Peng, Chifang
    Jin, Zhengyue
    Qiao, Ruirui
    Wang, Wuyang
    Zhu, Shuifang
    Wang, Libing
    Jing, Qinhui
    Xu, Chuanlai
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (07) : 2051 - 2056
  • [9] DEVELOPMENT OF A QUANTITATIVE AND SENSITIVE ENZYME-LINKED-IMMUNOSORBENT-ASSAY FOR OCHRATOXIN-A USING ANTIBODIES FROM THE YOLK OF THE LAYING HEN
    CLARKE, JR
    MARQUARDT, RR
    OOSTERVELD, A
    FROHLICH, AA
    MADRID, FJ
    DAWOOD, M
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1993, 41 (10) : 1784 - 1789
  • [10] Automated RNA selection
    Cox, JC
    Rudolph, P
    Ellington, AD
    [J]. BIOTECHNOLOGY PROGRESS, 1998, 14 (06) : 845 - 850