Radiation dose estimates in dual-source computed tomography coronary angiography

被引:203
作者
Stolzmann, Paul [1 ]
Scheffel, Hans [1 ]
Schertler, Thomas [1 ]
Frauenfelder, Thomas [1 ]
Leschka, Sebastian [1 ]
Husmann, Lars [1 ]
Flohr, Thomas G. [2 ]
Marincek, Borut [1 ]
Kaufmann, Philipp A. [3 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Seimens Med Solut, Forchheim, Germany
[3] Ctr Cardiovasc, Forchheim, Germany
关键词
coronary angiography; dual-source computed tomography; radiation dose;
D O I
10.1007/s00330-007-0786-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to quantify radiation dose parameters of dual-source CT coronary angiography. Eighty patients underwent contrast-enhanced, retrospectively ECG-gated dual-source CT coronary angiography with heart rate-adapted ECG pulsing using two algorithms: In 40 patients, the tube current was reduced to 20% (A(min1)) of the normal tube current (A(max)) outside the pulsing window; in 40 patients tube current was reduced to 4% (A(min2)) of A(max). Mean CTDIvol in the A(min1) group was 45.1 +/- 3.6 mGy; the mean CTDIvol in the A(min2) group was 39.1 +/- 3.2 mGy, with CTDIvol in the A(min2) group being significantly reduced when compared to the A(min1) group (P < 0.001). A significant negative correlation was found between CTDIvol and heart rate in group A(min1) (r=-0.82, P < 0.001), whereas no correlation was found between CTDIvol and heart rate in group A(min2) (r=-0.066). Using the conversion coefficient for the chest, dual-source CT coronary angiography resulted in an estimated mean effective dose of 8.8 mSv in the A(min1) group and 7.8 mSv in the A(min2). Radiation exposure of dual-source CT coronary angiography using an ECG-pulsing protocol reducing the tube current to 20% significantly decreases with increasing heart rates, despite using wider pulsing windows at higher heart rates. When using a protocol with reduced tube current of 4%, the radiation dose is significantly lower, irrespective of the heart rate.
引用
收藏
页码:592 / 599
页数:8
相关论文
共 29 条
[1]   Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]   Exposure of the Swiss population by radiodiagnostics: 2003 review [J].
Aroua, A. ;
Trueb, Ph. ;
Vader, J.-P. ;
Valley, J.-F. ;
Verdun, F. R. .
HEALTH PHYSICS, 2007, 92 (05) :442-448
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]  
Becker C, 1999, ROFO-FORTSCHR RONTG, V170, P99
[5]   Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography [J].
Coles, DR ;
Smail, MA ;
Negus, IS ;
Wilde, P ;
Oberhoff, M ;
Karsch, KR ;
Baumbach, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (09) :1840-1845
[6]   Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations [J].
Das, M ;
Mahnken, AH ;
Mühlenbruch, G ;
Stargardt, A ;
Weiss, C ;
Sennst, DA ;
Flohr, TG ;
Günther, RW ;
Wildberger, JE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (05) :1437-1443
[7]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[8]   Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography [J].
Gerber, TC ;
Kuzo, RS ;
Morin, RL .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (01) :165-176
[9]   Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310
[10]   Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation [J].
Jakobs, TF ;
Becker, CR ;
Ohnesorge, B ;
Flohr, T ;
Suess, C ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1081-1086