Endoleaks after endovascular repair of abdominal aortic aneurysms

被引:111
作者
Baum, RA
Stavropoulos, SW
Fairman, RM
Carpenter, JP
机构
[1] Brigham & Womens Hosp, Dept Radiol, Sect Intervent Radiol, Boston, MA 02115 USA
[2] Univ Penn, Med Ctr, Dept Radiol, Philadelphia, PA 19104 USA
[3] Univ Penn, Med Ctr, Dept Surg, Philadelphia, PA 19104 USA
关键词
D O I
10.1097/01.RVI.0000085773.71254.86
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Endovascular repair of abdominal aortic aneurysms shows promising initial results. Endoleaks represent one of the unique causes of endovascular repair failure not seen with traditional abdominal aortic aneurysm repair. Endoleaks occur when there is blood flow outside the stent-graft lumen but within the aneurysm sac. They can be difficult to diagnose and treat, and their management is a source of continued controversy. This review further defines endoleaks and the clinical challenges that they create. Current methods for endoleak detection, classification, and management are reviewed.
引用
收藏
页码:1111 / 1117
页数:7
相关论文
共 77 条
[41]  
Schurink GWH, 2000, J VASC SURG, V31, P501
[42]   Endoleak after stent-graft treatment of abdominal aortic aneurysm: a meta-analysis of clinical studies [J].
Schurink, GWH ;
Aarts, NJM ;
van Bockel, JH .
BRITISH JOURNAL OF SURGERY, 1999, 86 (05) :581-587
[43]   Endoleakage after stent-graft treatment of abdominal aneurysm: Implications on pressure and imaging - an in vitro study [J].
Schurink, GWH ;
Aarts, NJM ;
Wilde, J ;
van Baalen, JM ;
Chuter, TAM ;
Kool, LJ ;
van Bockel, JH .
JOURNAL OF VASCULAR SURGERY, 1998, 28 (02) :234-241
[44]   Experimental study of the influence of endoleak size on pressure in the aneurysm sac and the consequences of thrombosis [J].
Schurink, GWH ;
Aarts, NJM ;
van Baalen, JM ;
Kool, LJS ;
van Bockel, JH .
BRITISH JOURNAL OF SURGERY, 2000, 87 (01) :71-78
[45]   Endotension in an experimental aneurysm model [J].
Skillern, CS ;
Stevens, SL ;
Piercy, KT ;
Donnell, RL ;
Freeman, MB ;
Goldman, MH .
JOURNAL OF VASCULAR SURGERY, 2002, 36 (04) :814-817
[46]   Aortic aneurysm sac shrinkage after endovascular repair is device-dependent: A comparison of zenith and AneuRx endografts [J].
Sternbergh, WC ;
Conners, MS ;
Tonnessen, BH ;
Carter, G ;
Money, SR .
ANNALS OF VASCULAR SURGERY, 2003, 17 (01) :49-53
[47]   Treatment of type III endoleak with an aortouniiliac stent graft [J].
Teruya, TH ;
Ayerdi, J ;
Solis, MM ;
Abou-Zamzam, AM ;
Ballard, JL ;
McLafferty, RB ;
Hodgson, KJ .
ANNALS OF VASCULAR SURGERY, 2003, 17 (02) :123-128
[48]  
Teufelsbauer H, 2002, J ENDOVASC THER, V9, P896, DOI 10.1583/1545-1550(2002)009<0896:ETOAMP>2.0.CO
[49]  
2
[50]   Imaging of aortic stent-grafts and endoleaks [J].
Thurnher, S ;
Cejna, M .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2002, 40 (04) :799-+