A practical interface for microfluidics and nanoelectrospray mass spectrometry

被引:26
作者
Freire, Sergio L. S. [1 ]
Yang, Hao [1 ]
Wheeler, Aaron R. [1 ,2 ,3 ]
机构
[1] Univ Toronto, Dept Chem, Toronto, ON M5S 3H6, Canada
[2] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON M5S 3H6, Canada
[3] Univ Toronto, Banting & Best Dept Med Res, Toronto, ON M5S 3H6, Canada
关键词
lab-on-a-chip; mass spectrometry; microfluidics; nanoelectrospray ionization; proteomics;
D O I
10.1002/elps.200700661
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report a new method for fabricating nanospray ionization tips for MS, formed from glass substrates and the inert polymer, parylene-C. Using a single photolithography step, the emitters are formed contiguously with microchannels, such that no dead volumes are observed. In addition, because the devices are very thin (similar to 0.3 mm) and the tips are formed at rectangular corners, the Taylor cone volumes are small, which makes the method attractive for future integration with microfluidic separations. Device performance was demonstrated by evaluating diverse analytes, ranging from synthetic polymers, to peptides, to nucleic acids. For all analytes, performance was similar to that of conventional emitters (pulled-glass capillaries and the Agilent HPLC Chip (TM)) with the advantage of rapid, batch fabrication of identical devices.
引用
收藏
页码:1836 / 1843
页数:8
相关论文
共 41 条
[1]   Fabrication of porous polymer monoliths in polymeric microfluidic chips as an electrospray emitter for direct coupling to mass spectrometry [J].
Bedair, MF ;
Oleschuk, RD .
ANALYTICAL CHEMISTRY, 2006, 78 (04) :1130-1138
[2]   Microfluidic devises connected to fused-silica capillaries with minimal dead volume [J].
Bings, NH ;
Wang, C ;
Skinner, CD ;
Colyer, CL ;
Thibault, P ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3292-3296
[3]   A MALDI-chip integrated system with a monitoring window [J].
Brivio, M ;
Tas, NR ;
Goedbloed, MH ;
Gardeniers, HJGE ;
Verboom, W ;
van den Berg, A ;
Reinhoudt, DN .
LAB ON A CHIP, 2005, 5 (04) :378-381
[4]   Microfabricated polymer devices for automated sample delivery of peptides for analysis by electrospray ionization tandem mass spectrometry [J].
Chan, JH ;
Timperman, AT ;
Qin, D ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4437-4444
[5]  
Chen SH, 2001, ELECTROPHORESIS, V22, P3972, DOI 10.1002/1522-2683(200110)22:18<3972::AID-ELPS3972>3.0.CO
[6]  
2-6
[7]   Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip [J].
Dahlin, AP ;
Wetterhall, M ;
Liljegren, G ;
Bergström, SK ;
Andrén, P ;
Nyholm, L ;
Markides, KE ;
Bergquist, J .
ANALYST, 2005, 130 (02) :193-199
[8]   Chip-based capillary electrophoresis/mass spectrometry determination of carnitines in human urine [J].
Deng, YZ ;
Henion, J ;
Li, JJ ;
Thibault, P ;
Wang, C ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :639-646
[9]   Integrated microfluidic device for mass spectrometry-based proteomics and its application to biomarker discovery programs [J].
Fortier, MH ;
Bonneil, E ;
Goodley, P ;
Thibault, P .
ANALYTICAL CHEMISTRY, 2005, 77 (06) :1631-1640
[10]   Proteome-on-a-chip: Mirage, or on the horizon? [J].
Freire, Sergio L. S. ;
Wheeler, Aaron R. .
LAB ON A CHIP, 2006, 6 (11) :1415-1423