Absolute dose calculations for Monte Carlo simulations of radiotherapy beams

被引:106
作者
Popescu, IA [1 ]
Shaw, CP
Zavgorodni, SF
Beckham, WA
机构
[1] British Columbia Canc Agcy, Dept Med Phys, Victoria, BC, Canada
[2] Univ Victoria, Dept Phys & Astron, Victoria, BC, Canada
关键词
D O I
10.1088/0031-9155/50/14/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monte Carlo (MC) simulations have traditionally been used for single field relative comparisons with experimental data or commercial treatment planning systems (TPS). However, clinical treatment plans commonly involve more than one field. Since the contribution of each field must be accurately quantified, multiple field MC simulations are only possible by employing absolute dosimetry. Therefore, we have developed a rigorous calibration method that allows the incorporation of monitor units (MU) in MC simulations. This absolute dosimetry formalism can be easily implemented by any BEAMnrc/DOSXYZnrc user, and applies to any configuration of open and blocked fields, including intensity-modulated radiation therapy (IMRT) plans. Our approach involves the relationship between the dose scored in the monitor ionization chamber of a radiotherapy linear accelerator (linac), the number of initial particles incident on the target, and the field size. We found that for a 10 x 10 cm(2) field of a 6 MV photon beam, I MU corresponds, in our model, to 8.129 x 10(13) +/- 1.0% electrons incident on the target and a total dose of 20.87 cGy +/- 1.0% in the monitor chambers of the virtual linac. We present an extensive experimental verification of our MC results for open and intensity-modulated fields, including a dynamic 7-field IMRT plan simulated on the CT data sets of a cylindrical phantom and of a Rando anthropomorphic phantom, which were validated by measurements using ionization chambers and thermoluminescent dosimeters (TLD). Our simulation results are in excellent agreement with experiment, with percentage differences of less than 2%, in general, demonstrating the accuracy of our Monte Carlo absolute dose calculations.
引用
收藏
页码:3375 / 3392
页数:18
相关论文
共 29 条
[1]  
Andreo P, 2003, PHYS MED BIOL, V48, pL46
[2]   Modelling an extreme water-lung interface using a single pencil beam algorithm and the Monte Carlo method [J].
Cranmer-Sargison, G ;
Beckham, WA ;
Popescu, IA .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (08) :1557-1567
[3]   Using Monte Carlo simulations to commission photon beam output factors - a feasibility study [J].
Ding, GX .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (23) :3865-3874
[4]  
DING GX, 2002, PHYS MED BIOL, V47, P2256
[5]   BACKSCATTER INTO THE BEAM MONITOR CHAMBER - IMPLICATIONS FOR DOSIMETRY OF ASYMMETRIC COLLIMATORS [J].
DUZENLI, C ;
MCCLEAN, B ;
FIELD, C .
MEDICAL PHYSICS, 1993, 20 (02) :363-367
[6]   Summary and recommendations of a National Cancer Institute workshop on issues limiting the clinical use of Monte Carlo dose calculation algorithms for megavoltage external beam radiation therapy [J].
Fraass, BA ;
Smathers, J ;
Deye, J .
MEDICAL PHYSICS, 2003, 30 (12) :3206-3216
[7]   Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM [J].
Francescon, P ;
Cavedon, C ;
Reccanello, S ;
Cora, S .
MEDICAL PHYSICS, 2000, 27 (07) :1579-1587
[8]   Dosimetric evaluation of the clinical implementation of the first commercial IMRT Monte Carlo treatment planning system at 6 MV [J].
Heath, E ;
Seuntjens, J ;
Sheikh-Bagheri, D .
MEDICAL PHYSICS, 2004, 31 (10) :2771-2779
[9]   THE EFFECT OF COLLIMATOR BACKSCATTER RADIATION ON PHOTON OUTPUT OF LINEAR ACCELERATORS [J].
HUANG, PH ;
CHU, J ;
BJARNGARD, BE .
MEDICAL PHYSICS, 1987, 14 (02) :268-269
[10]   HEAD SCATTER DATA FOR SEVERAL LINEAR ACCELERATORS (4-18MV) [J].
KASE, KR ;
SVENSSON, GK .
MEDICAL PHYSICS, 1986, 13 (04) :530-532