Intravascular and intracardiac stents used in congenital heart disease

被引:33
作者
Okubo, M [1 ]
Benson, LN [1 ]
机构
[1] Univ Toronto, Hosp Sick Children, Sch Med,Dept Pediat, Div Cardiol,Variety Club Catheterizat Labs, Toronto, ON M5G 1X8, Canada
关键词
D O I
10.1097/00001573-200103000-00002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intravascular or intracardiac stenoses occur in many forms of congenital heart disease or after attempted surgical repair. Although balloon dilation is one option for management, restenosis can occur due to elastic recoil immediately after the procedure. To address to such stenotic lesions, many reports support implanting endovascular stents to provide a framework for vessel expansion. Both balloon-expandable fixed tubular mesh stainless steel devices, and self-expandable stents have had an extensive clinical application. In pediatric patients, stents are used for a variety of stenoses, such as systemic venous obstruction pathways (eg, Mustard, Fontan baffle, or bidirectional cavopulmonary connections), pulmonary artery, right ventricular to pulmonary conduits, aortic coarctation, the arterial duct, aorticopulmonary collaterals, or postoperative systemic to pulmonary shunts, Because of improvements in device profile, implantation rates have increased. Complications such as stent fracture, migration, aneurysm formation, and in-stent restenosis occur but only rarely. This latter event may be because of intimal hyperplasia and/or continued vessel (and patient) growth related to the stent diameter. As such, some instances require redilation to manage the acquired lesion. Stent application has importantly altered management algorithms in congenital heart disease. Curr Opin Cardiol 2001, 16:84-91 (C) 2001 Lippincott Williams & Wilkins, Inc.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 65 条
[21]   Stent and artery geometry determine intimal thickening independent of arterial injury [J].
Garasic, JM ;
Edelman, ER ;
Squire, JC ;
Seifert, P ;
Williams, MS ;
Rogers, C .
CIRCULATION, 2000, 101 (07) :812-818
[22]   Acute and chronic tissue response to coronary stent implantation:: Pathologic findings in human specimen [J].
Grewe, PH ;
Deneke, T ;
Machraoui, A ;
Barmeyer, J ;
Müller, KM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (01) :157-163
[23]  
Hashmi A, 1999, CATHETER CARDIO INTE, V46, P333, DOI 10.1002/(SICI)1522-726X(199903)46:3<333::AID-CCD14>3.3.CO
[24]  
2-W
[25]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254
[26]   Dilation mechanism, causes of restenosis and stenting in balloon coarctation angioplasty [J].
Ino, T ;
Ohkubo, M .
ACTA PAEDIATRICA, 1997, 86 (04) :367-371
[27]   Increased risk of restenosis after placement of gold-coated stents -: Results of a randomized trial comparing gold-coated with uncoated steel stents in patients with coronary artery disease [J].
Kastrati, A ;
Schömig, A ;
Dirschinger, J ;
Mehilli, J ;
von Welser, N ;
Pache, J ;
Schühlen, H ;
Schilling, T ;
Schmitt, C ;
Neumann, FJ .
CIRCULATION, 2000, 101 (21) :2478-2483
[28]   Histopathology of in-stent restenosis in patients with peripheral artery disease [J].
Kearney, M ;
Pieczek, A ;
Haley, L ;
Losordo, DW ;
Andres, V ;
Schainfeld, R ;
Rosenfield, K ;
Isner, JM .
CIRCULATION, 1997, 95 (08) :1998-2002
[29]   LOCALIZED ARTERIAL-WALL DRUG-DELIVERY FROM A POLYMER-COATED REMOVABLE METALLIC STENT - KINETICS, DISTRIBUTION, AND BIOACTIVITY OF FORSKOLIN [J].
LAMBERT, TL ;
DEV, V ;
RECHAVIA, E ;
FORRESTER, JS ;
LITVACK, F ;
EIGLER, NL .
CIRCULATION, 1994, 90 (02) :1003-1011
[30]   Stent implantation for aortic coarctation and recoarctation [J].
Magee, AG ;
Brzezinska-Rajszys, G ;
Qureshi, SA ;
Rosenthal, E ;
Zubrzycka, M ;
Ksiazyk, J ;
Tynan, M .
HEART, 1999, 82 (05) :600-606