Effects of through-plane myocardial motion on phase-difference and complex-difference measurements of absolute coronary artery flow

被引:17
作者
Polzin, JA [1 ]
Korosec, FR [1 ]
Wedding, KL [1 ]
Grist, TM [1 ]
Frayne, R [1 ]
Peters, DC [1 ]
Mistretta, CA [1 ]
机构
[1] UNIV WISCONSIN,DEPT PHYS MED,MADISON,WI 53792
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1996年 / 6卷 / 01期
关键词
flow; coronary artery; vessel motion; simulations; humans;
D O I
10.1002/jmri.1880060122
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have previously reported on a complex-difference (CD) now measurement technique that produces more accurate results than the phase-difference (PD) now measurement technique due to the greater immunity of the former method to partial volume effects. We report here on some of the ways in which through-plane myocardial motion affects the accuracy of absolute coronary artery now measurements obtained using the PD and CD techniques. We also discuss motion correction schemes that can be applied to the PD and CD processing methods to improve their accuracy. Computer simulations have been performed to assess the magnitude of the errors associated with these now measurement techniques when they are applied to small vessels that are attached to a moving background. Laminar and plug now, with and without complete background suppression, have been considered, Experiments with a moving vessel phantom have been conducted to test the performance of the PD and CD now measurement techniques in circumstances similar to those simulated, The simulations and the experiments showed that, after corrections for through-plane motion are made, the CD method generally yields more accurate now results than the PD method. As shown by the simulations, however, both methods yield compromised results due to subtle saturation effects that occur when the direction of myocardial motion is opposite the direction of blood now, Unvalidated PD and CD measurements of coronary artery now waveforms in human volunteers are presented to illustrate the magnitude of the proposed through-plane motion effects in vivo.
引用
收藏
页码:113 / 123
页数:11
相关论文
共 17 条
[1]  
Chien D., 1994, P SOC MAGN RES 1994, P373
[2]   FLOW VELOCITY QUANTIFICATION IN HUMAN CORONARY-ARTERIES WITH FAST, BREATH-HOLD MR-ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
GERVINO, E ;
LI, W .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05) :699-703
[3]   IMPROVED EJECTION FRACTION AND FLOW VELOCITY ESTIMATES WITH USE OF VIEW SHARING AND UNIFORM REPETITION TIME EXCITATION WITH FAST CARDIAC TECHNIQUES [J].
FOO, TKF ;
BERNSTEIN, MA ;
AISEN, AM ;
HERNANDEZ, RJ ;
COLLICK, BD ;
BERNSTEIN, T .
RADIOLOGY, 1995, 195 (02) :471-478
[4]   COMPUTER-CONTROLLED FLOW SIMULATOR FOR MR FLOW STUDIES [J].
FRAYNE, R ;
HOLDSWORTH, DW ;
GOWMAN, LM ;
RICKEY, DW ;
DRANGOVA, M ;
FENSTER, A ;
RUTT, BK .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (05) :605-612
[5]  
GALJEE M, 1993, P SOC MAGNETIC RESON, P552
[6]   CORONARY FLOW RESERVE AS A PHYSIOLOGIC MEASURE OF STENOSIS SEVERITY [J].
GOULD, KL ;
KIRKEEIDE, RL ;
BUCHI, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (02) :459-474
[7]   THE APPLICATION OF BREATH-HOLD PHASE-VELOCITY MAPPING TECHNIQUES TO THE MEASUREMENT OF CORONARY-ARTERY FLOOD FLOW VELOCITY - PHANTOM DATA AND INITIAL IN-VIVO RESULTS [J].
KEEGAN, J ;
FIRMIN, D ;
GATEHOUSE, P ;
LONGMORE, D .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) :526-536
[8]  
KEEGAN J, 1994, P SOC MAGN RES 1994, P149
[9]   ARTERIAL AND VENOUS-BLOOD FLOW - NONINVASIVE QUANTITATION WITH MR IMAGING [J].
PELC, LR ;
PELC, NJ ;
RAYHILL, SC ;
CASTRO, LJ ;
GLOVER, GH ;
HERFKENS, RJ ;
MILLER, DC ;
JEFFREY, RB .
RADIOLOGY, 1992, 185 (03) :809-812
[10]  
PELC N J, 1991, Magnetic Resonance Quarterly, V7, P229