Metallic prosthesis: Technique to avoid increase in CT radiation dose with automatic tube current modulation in a phantom and patients

被引:34
作者
Dalal, T
Kalra, MK [1 ]
Rizzo, SMR
Schmidt, B
Suess, C
Flohr, T
Blake, MA
Saini, S
机构
[1] Emory Univ, Sch Med, Dept Radiol, Atlanta, GA 30322 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Div Abdominal Imaging & Intervent, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Boston, MA 02114 USA
[4] Siemens Med Solut, Forchheim, Germany
关键词
D O I
10.1148/radiol.2362041565
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The institutional review board approved this Health Insurance Portability and Accountability Act-compliant study protocol, with waiver of informed consent. The purpose of the study was to retrospectively evaluate the combined automatic tube current modulation technique in patients with orthopedic metallic prostheses. Five hundred abdominal-pelvic computed tomographic (CT) studies performed with combined modulation technique were reviewed to identify nine patients with metallic prostheses (mean age, 66 years; range, 35-86 years; male-female ratio, 5:4). On the basis of age and transverse abdominal images, these patients were matched with nine others with no metallic prostheses (mean age, 56 years; range, 36-72 years; male-female ratio, 4:5) who were control patients. Images were graded for extent and severity of streak artifacts (grade 1, streak artifact present but not substantially compromising evaluation of adjacent structures; grade 2, streak artifact present and slightly compromising evaluation of adjacent structures; and grade 3, streak artifact present and severely compromising evaluation of adjacent structures). Student t test was performed for statistical analysis. There was no difference in mean effective tube current-time product between study and control patients (P >.49). With automatic tube current modulation, an increase in CT dose caused by metallic prostheses can be successfully avoided.(c) RSNA, 2005.
引用
收藏
页码:671 / 675
页数:5
相关论文
共 12 条
[1]   Pediatric multidetector body CT [J].
Donnelly, LF ;
Frush, DP .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2003, 41 (03) :637-+
[2]  
FIALA TGS, 1993, PLAST RECONSTR SURG, V92, P1227
[3]   Improved pediatric multidetector body CT using a size-based color-coded format [J].
Frush, DP ;
Soden, B ;
Frush, KS ;
Lowry, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) :721-726
[4]  
Greess HR, 2002, RADIOLOGY, V225, P593
[5]   CT SCANS THROUGH METAL SCANNING TECHNIQUE VERSUS HARDWARE COMPOSITION [J].
HARAMATI, N ;
STARON, RB ;
MAZELSPERLING, K ;
FREEMAN, K ;
NICKOLOFF, EL ;
BARAX, C ;
FELDMAN, F .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1994, 18 (06) :429-434
[6]  
Horiuchi T., 2002, JPN SOC RADIOL TECH, V78, P166
[7]   Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628
[8]   Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: Effect on image quality [J].
Kalra, MK ;
Prasad, S ;
Saini, S ;
Blake, MA ;
Varghese, J ;
Halpern, EF ;
Thrall, JH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) :1101-1106
[9]  
Mahnken AH, 2003, INVEST RADIOL, V38, P769, DOI 10.1097/01.rli.0000086495.96457.54
[10]   Do metallic endoprostheses increase radiation dose associated with automatic tube-current modulation in abdominal-pelvic MDCT? A phantom and patient study [J].
Rizzo, SMR ;
Kalra, MK ;
Maher, MM ;
Blake, MA ;
Toth, TL ;
Saini, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) :491-496