Contrast injection protocols for coronary computed tomography angiography using a 64-detector scanner: Comparison between patient weight-adjusted and fixed iodine-dose protocols

被引:77
作者
Nakaura, Takeshi [1 ]
Awai, Kazuo [1 ]
Yauaga, Yumi [1 ]
Nakayama, Yoshiharu [1 ]
Oda, Seitaro [1 ]
Hatemura, Masahiro [2 ]
Nagayoshi, Yasuhiro [3 ]
Ogawa, Hisao [3 ]
Yamashita, Yasuyuki [1 ]
机构
[1] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto 8608556, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Radiol, Kumamoto 8608556, Japan
[3] Kumamoto Univ, Grad Sch Med Sci, Dept Cardiovasc Med, Kumamoto 8608556, Japan
关键词
multidetector computed tomography; contrast media; vessel enhancement; injection protocol;
D O I
10.1097/RLI.0b013e3181727505
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare patient-weight-adjusted and fixed iodine-dose protocols at coronary computed tomography angiography (CTA) using a 64-detector scanner and computer-assisted bolus tracking. Materials and Methods: Approval from our institutional review board and patient prior informed consent were obtained before entering 60 patients with suspected coronary disease in this study. The patients were randomly assigned to one of 2 protocols. In the fixed iodine-dose protocol, they received a fixed dose of 80 mL Iopamidol-370; the injection duration was 20 seconds. In the weight-adjusted iodine-dose protocol, the dose was tailored to the patient body weight; this group received 1.0 mL/kg and the injection duration was shorter, ie, 15 seconds. Imaging was on a 64-detector CT scanner using a computer-assisted bolus tracking technique. A radiologist blinded to the protocol used measured the Hounsfield density number of the large vessels and coronary arteries. CT attenuation in the aortic root was compared in patients whose weight was less than 58 kg (group 1) or 58 kg or more (group 2). The standard deviation (SD) of CT attenuation in the aortic root and the myocardium was compared with evaluate image noise. Using a 3-point scale, 2 radiologists independently evaluated beam-hardening artifacts and coronary enhancement. Statistical analysis was with the two-tailed Student t test and the Mann-Whitney U test. Results: There was no significant difference between the protocols with respect to CT attenuation of the ascending aorta and coronary arteries. Under the fixed-iodine-dose protocol, mean CT attenuation in the aortic root was 421.3 +/- 51.5 Hounsfield unit (HU) in the lighter-, and 397.2 +/- 42.3 HU in the heavier weight group, respectively; the difference was statistically significant (P = 0.03). Under the weight-adjusted iodine-dose protocol, these values were 407.6 +/- 85.1 and 409.2 +/- 47.9 HU, respectively and the difference was not statistically significant (P = 0.17). The SD of the ascending aorta and myocardium was significantly higher for the fixed- than the weight-adjusted iodine-dose protocol. The mean visual score for beam-hardening artifacts was significantly lower in the weight-adjusted- than the fixed-iodine-dose protocol (P < 0.01), however, there was no significant difference in the enhancement of the coronary arteries (P = 0.82). Conclusion: At 64-detector CTA of the heart, the patient weight-tailored dose protocol with the 15-second injection duration yielded significantly better image quality than the fixed-dose, 20-second injection duration protocol.
引用
收藏
页码:512 / 519
页数:8
相关论文
共 32 条
[1]   Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight [J].
Awai, K ;
Hiraishi, K ;
Hori, S .
RADIOLOGY, 2004, 230 (01) :142-150
[2]   Effect of contrast injection protocol with dose tailored to patient weight and fixed injection duration on aortic and hepatic enhancement at multidetector-row helical CT [J].
Awai, K ;
Hori, S .
EUROPEAN RADIOLOGY, 2003, 13 (09) :2155-2160
[3]   Prediction of aortic peak enhancement in monophasic contrast injection protocols at multidetector CT: Phantom and patient studies [J].
Awai K. ;
Nakayama Y. ;
Nakaura T. ;
Yanaga Y. ;
Tamura Y. ;
Hatemura M. ;
Funama Y. ;
Yamashita Y. .
Radiation Medicine, 2007, 25 (1) :14-21
[4]   Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method [J].
Bae, KT ;
Tran, HQ ;
Heiken, JP .
RADIOLOGY, 2004, 231 (03) :732-736
[5]   Peak contrast enhancement in CT and MR angiography: When does it occur and why? Pharmacokinetic study in a porcine model [J].
Bae, KT .
RADIOLOGY, 2003, 227 (03) :809-816
[6]   Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :657-662
[7]   Aortic and hepatic contrast medium enhancement at CT part I. Prediction with a computer model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :647-655
[8]   Optimal contrast application for cardiac 4-detector-row computed tomography [J].
Becker, CR ;
Hong, C ;
Knez, A ;
Leber, A ;
Bruening, R ;
Schoepf, UJ ;
Reiser, MF .
INVESTIGATIVE RADIOLOGY, 2003, 38 (11) :690-694
[9]   Effect of the arterial input function on the measured perfusion values and infarct volumetric in acute cerebral ischemia evaluated by perfusion computed tomography [J].
Bisdas, Sotirios ;
Konstantinou, George N. ;
Gurung, Jessen ;
Lehnert, Thomas ;
Donnerstag, Frank ;
Becker, Hartmut ;
Vogl, Thomas J. ;
Koh, Tong San .
INVESTIGATIVE RADIOLOGY, 2007, 42 (03) :147-156
[10]   Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser [J].
Cademartiri, F ;
Mollet, N ;
van der Lugt, A ;
Nieman, K ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
EUROPEAN RADIOLOGY, 2004, 14 (02) :178-183