Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners

被引:77
作者
Das, Marco
Ley-Zaporozhan, Julia
Gietema, H. A.
Czech, Andre
Muehlenbruch, Georg
Mahnken, Andreas H.
Katoh, Markus
Bakai, Annemarie
Salganicoff, Marcos
Diederich, Stefan
Prokop, Mathias
Kauczor, Hans-Ulrich
Guenther, Rolf W.
Wildberger, Joachim E.
机构
[1] Rhein Westfal TH Aachen Univ, Dept Diagnost Radiol, D-52072 Aachen, Germany
[2] German Canc Res Ctr, Dept Radiol, D-6900 Heidelberg, Germany
[3] Univ Utrecht Hosp, Dept Diagnost Radiol, Utrecht, Netherlands
[4] Marien Hosp, Dept Diagnost Radiol, Dusseldorf, Germany
关键词
multislice CT; pulmonary nodule; nodule volumetry; automated volumetry; chest CT;
D O I
10.1007/s00330-006-0562-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to compare the accuracy of an automated volumetry software for phantom pulmonary nodules across various 16-slice multislice spiral CT (MSCT) scanners from different vendors. A lung phantom containing five different nodule categories (intraparenchymal, around a vessel, vessel attached, pleural, and attached to the pleura), with each category comprised of 7-9 nodules (total, n=40) of varying sizes (diameter 3-10 mm; volume 6.62 mm(3)-525 mm(3)), was scanned with four different 16-slice MSCT scanners (Siemens, GE, Philips, Toshiba). Routine and low-dose chest protocols with thin and thick collimations were applied. The data from all scanners were used for further analysis using a dedicated prototype volumetry software. Absolute percentage volume errors (APE) were calculated and compared. The mean APE for all nodules was 8.4% ( +/- 7.7%) for data acquired with the 16-slice Siemens scanner, 14.3% ( +/- 11.1%) for the GE scanner, 9.7% ( +/- 9.6%) for the Philips scanner and 7.5% ( +/- 7.2%) for the Toshiba scanner, respectively. The lowest APEs were found within the diameter size range of 5-10 mm and volumes > 66 mm(3). Nodule volumetry is accurate with a reasonable volume error in data from different scanner vendors. This may have an important impact for intraindividual follow-up studies.
引用
收藏
页码:1979 / 1984
页数:6
相关论文
共 26 条
[21]   The solitary pulmonary nodule [J].
Tan, BB ;
Flaherty, KR ;
Kazerooni, EA ;
Iannettoni, MD .
CHEST, 2003, 123 (01) :89S-96S
[22]   Value of axial and coronal maximum intensity projection (MIP) images in the detection of pulmonary nodules by multislice spiral CT: comparison with axial 1-mm and 5-mm slices [J].
Valencia, R ;
Denecke, T ;
Lehmkuhl, L ;
Fischbach, F ;
Felix, R ;
Knollmann, F .
EUROPEAN RADIOLOGY, 2006, 16 (02) :325-332
[23]   Aspects of computer-aided detection (CAD) and volumetry of pulmonary nodules using multislice CT [J].
Wiemker, R ;
Rogalla, P ;
Blaffert, T ;
Sifri, D ;
Hay, O ;
Shah, E ;
Truyen, R ;
Fleiter, T .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 :S46-S56
[24]   Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT [J].
Wormanns, D ;
Ludwig, K ;
Beyer, F ;
Heindel, W ;
Diederich, S .
EUROPEAN RADIOLOGY, 2005, 15 (01) :14-22
[25]   Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility [J].
Wormanns, D ;
Kohl, G ;
Klotz, E ;
Marheine, A ;
Beyer, F ;
Heindel, W ;
Diederich, S .
EUROPEAN RADIOLOGY, 2004, 14 (01) :86-92
[26]   Small pulmonary nodules: Volumetrically determined growth rates based on CT evaluation [J].
Yankelevitz, DF ;
Reeves, AP ;
Kostis, WJ ;
Zhao, BS ;
Henschke, CI .
RADIOLOGY, 2000, 217 (01) :251-256