The limited ability to control for the location of a tumour compromises the accuracy with which radiation can be delivered to tumour-bearing tissue. The resultant requirement for larger treatment volumes to accommodate target uncertainty restricts the radiation dose because more surrounding normal tissue is exposed. With image-guided radiotherapy (IGRT) these volumes can be optimized and tumoricidal doses can be delivered, achieving maximal tumour control with minimal complications. Moreover, with the ability of high-precision dose delivery and real-time knowledge of the target volume location, IGRT has initiated the exploration of new indications for radiotherapy, some of which were previously considered infeasible.
引用
收藏
页码:949 / 960
页数:12
相关论文
共 137 条
[1]   Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate [J].
Alasti, H ;
Petric, MP ;
Catton, CN ;
Warde, PR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :869-884
[2]  
Aoki Y, 1987, Radiat Med, V5, P131
[3]   Imaging and alignment for image-guided radiation therapy [J].
Balter, James M. ;
Kessler, Marc L. .
JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (08) :931-937
[4]   Target margins for random geometrical treatment uncertainties in conformal radiotherapy [J].
Bel, A ;
vanHerk, M ;
Lebesque, JV .
MEDICAL PHYSICS, 1996, 23 (09) :1537-1545
[5]   A computerized remote table control for fast on-line patient repositioning: Implementation and clinical feasibility [J].
Bel, A ;
Petrascu, O ;
Van de Vondel, I ;
Coppens, L ;
Linthout, N ;
Verellen, D ;
Storme, G .
MEDICAL PHYSICS, 2000, 27 (02) :354-358
[6]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[7]   Theragnostic imaging for radiation oncology: dose-painting by numbers [J].
Bentzen, SM .
LANCET ONCOLOGY, 2005, 6 (02) :112-117
[8]   Timeline - Radiation oncology: a century of achievements [J].
Bernier, J ;
Hall, EJ ;
Giaccia, A .
NATURE REVIEWS CANCER, 2004, 4 (09) :737-U15
[9]   A DIAGNOSTIC X-RAY FIELD VERIFICATION DEVICE FOR A 10 MV LINEAR-ACCELERATOR [J].
BIGGS, PJ ;
GOITEIN, M ;
RUSSELL, MD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (03) :635-643
[10]   Radiotherapy plus cetuximab for squamous-cell carcinoma of the head and neck [J].
Bonner, JA ;
Harari, PM ;
Giralt, J ;
Azarnia, N ;
Shin, DM ;
Cohen, RB ;
Jones, CU ;
Sur, R ;
Raben, D ;
Jassem, J ;
Ove, R ;
Kies, MS ;
Baselga, J ;
Youssoufian, H ;
Amellal, N ;
Rowinsky, EK ;
Ang, KK .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 354 (06) :567-578