A feasible method for clinical delivery verification and dose reconstruction in tomotherapy

被引:86
作者
Kapatoes, JM
Olivera, GH
Ruchala, KJ
Smilowitz, JB
Reckwerdt, PJ
Mackie, TR
机构
[1] Univ Wisconsin, Madison, WI 53706 USA
[2] TomoTherapy Inc, Middleton, WI 53562 USA
关键词
delivery verification; tomotherapy; dose reconstruction;
D O I
10.1118/1.1352579
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Delivery verification is the process in which the energy fluence delivered during a treatment is verified. This verified energy fluence can be used in conjunction with an image in the treatment position to reconstruct the full three-dimensional dose deposited. A method for delivery verification that utilizes a measured database of detector signal is described in this work. This database is a function of two parameters, radiological path-length and detector-to-phantom distance, both of which are computed from a CT image taken at the time of delivery. Such a database was generated and used to perform delivery verification and dose reconstruction. Two experiments were conducted: a simulated prostate delivery on an inhomogeneous abdominal phantom, and a nasopharyngeal delivery on a dog cadaver. For both cases, it was found that the verified fluence and dose results using the database approach agreed very well with those using previously developed and proven techniques. Delivery verification with a measured database and CT image at the time of treatment is an accurate procedure for tomotherapy. The database eliminates the need for any patient-specific, pre- or post-treatment measurements. Moreover, such an approach creates an opportunity for accurate, real-time delivery verification and dose reconstruction given fast image reconstruction and dose computation tools. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:528 / 542
页数:15
相关论文
共 57 条
  • [41] Megavoltage CT on a tomotherapy system
    Ruchala, KJ
    Olivera, GH
    Schloesser, EA
    Mackie, TR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (10) : 2597 - 2621
  • [42] Megavoltage CT image reconstruction during tomotherapy treatments
    Ruchala, KJ
    Olivera, GH
    Kapatoes, JM
    Schloesser, EA
    Reckwerdt, PJ
    Mackie, TR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12) : 3545 - 3562
  • [43] Ruchala KJ, 2000, USE OF COMPUTERS IN RADIATION THERAPY, P314
  • [44] Megavoltage CT imaging as a by-product of multileaf collimator leakage
    Ruchala, KJ
    Olivera, GH
    Kapatoes, JM
    Schloesser, EA
    Reckwerdt, PJ
    Mackie, TR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07) : N61 - N70
  • [45] Iterative approaches to dose optimization in tomotherapy
    Shepard, DM
    Olivera, GH
    Reckwerdt, PJ
    Mackie, TR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (01) : 69 - 90
  • [46] FAST CALCULATION OF THE EXACT RADIOLOGICAL PATH FOR A 3-DIMENSIONAL CT ARRAY
    SIDDON, RL
    [J]. MEDICAL PHYSICS, 1985, 12 (02) : 252 - 255
  • [47] CALCULATION OF THE RADIOLOGICAL DEPTH
    SIDDON, RL
    [J]. MEDICAL PHYSICS, 1985, 12 (01) : 84 - 87
  • [49] Scattered radiation in portal images: A Monte Carlo simulation and a simple physical model
    Swindell, W
    Evans, PM
    [J]. MEDICAL PHYSICS, 1996, 23 (01) : 63 - 73
  • [50] ARE PORT FILMS RELIABLE FOR INVIVO EXIT DOSE MEASUREMENTS
    VANDAM, J
    VAERMAN, C
    BLANCKAERT, N
    LEUNENS, G
    DUTREIX, A
    VANDERSCHUEREN, E
    [J]. RADIOTHERAPY AND ONCOLOGY, 1992, 25 (01) : 67 - 72