A feasible method for clinical delivery verification and dose reconstruction in tomotherapy

被引:86
作者
Kapatoes, JM
Olivera, GH
Ruchala, KJ
Smilowitz, JB
Reckwerdt, PJ
Mackie, TR
机构
[1] Univ Wisconsin, Madison, WI 53706 USA
[2] TomoTherapy Inc, Middleton, WI 53562 USA
关键词
delivery verification; tomotherapy; dose reconstruction;
D O I
10.1118/1.1352579
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Delivery verification is the process in which the energy fluence delivered during a treatment is verified. This verified energy fluence can be used in conjunction with an image in the treatment position to reconstruct the full three-dimensional dose deposited. A method for delivery verification that utilizes a measured database of detector signal is described in this work. This database is a function of two parameters, radiological path-length and detector-to-phantom distance, both of which are computed from a CT image taken at the time of delivery. Such a database was generated and used to perform delivery verification and dose reconstruction. Two experiments were conducted: a simulated prostate delivery on an inhomogeneous abdominal phantom, and a nasopharyngeal delivery on a dog cadaver. For both cases, it was found that the verified fluence and dose results using the database approach agreed very well with those using previously developed and proven techniques. Delivery verification with a measured database and CT image at the time of treatment is an accurate procedure for tomotherapy. The database eliminates the need for any patient-specific, pre- or post-treatment measurements. Moreover, such an approach creates an opportunity for accurate, real-time delivery verification and dose reconstruction given fast image reconstruction and dose computation tools. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:528 / 542
页数:15
相关论文
共 57 条
  • [51] WEBB S, 1997, PHYSICS CONFORMAL RA
  • [52] Wilkinson J., 1971, HDB AUTOMATIC COMPUT, VII
  • [53] PORTAL DOSE IMAGES .1. QUANTITATIVE TREATMENT PLAN VERIFICATION
    WONG, JW
    SLESSINGER, ED
    HERMES, RE
    OFFUTT, CJ
    ROY, T
    VANNIER, MW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (06): : 1455 - 1463
  • [54] Investigation of tomotherapy beam delivery
    Yang, JN
    Mackie, TR
    Reckwerdt, P
    Deasy, JO
    Thomadsen, BR
    [J]. MEDICAL PHYSICS, 1997, 24 (03) : 425 - 436
  • [55] INPUT/OUTPUT CHARACTERISTICS OF A MATRIX ION-CHAMBER ELECTRONIC PORTAL IMAGING DEVICE
    YIN, FF
    SCHELL, MC
    RUBIN, P
    [J]. MEDICAL PHYSICS, 1994, 21 (09) : 1447 - 1454
  • [56] PORTAL DOSE IMAGES .2. PATIENT DOSE ESTIMATION
    YING, XR
    GEER, LY
    WONG, JW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (06): : 1465 - 1475
  • [57] PORTAL DOSIMETRY USING A LIQUID ION-CHAMBER MATRIX - DOSE-RESPONSE STUDIES
    ZHU, YP
    JIANG, XQ
    VANDYK, J
    [J]. MEDICAL PHYSICS, 1995, 22 (07) : 1101 - 1106