A (short) history of image-guided radiotherapy

被引:130
作者
Verellen, Dirk [1 ]
De Ridder, Mark [1 ]
Storme, Guy [1 ]
机构
[1] UZ Brussel, Oncol Centrum, B-1090 Brussels, Belgium
关键词
image-guidance; IGRT; historical overview;
D O I
10.1016/j.radonc.2007.11.023
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Progress in radiotherapy is guided by the need to realize improved dose distributions, i.e. the ability to reduce the treatment volume toward the target volume and still ensuring coverage of that target volume in all dimensions. Poor ability to control the tumour's location limits the accuracy with which radiation can be delivered to tumour-bearing tissue. Image-guided radiation therapy (IGRT) aims at in-room imaging guiding the radiation delivery based on instant knowledge of the target location and changes in tumour volume during treatment. Advancements are usually not to be attributed to a single event, but rather a combination of many small improvements that together enable a superior result. Image-guidance is an important link in the treatment chain and as such a major factor in this synergetic process. A historic review shows that many of the so-called new developments are not so new at all, but did not make it into mainstream radiotherapy practice at that time. Recent developments in improved IT infrastructures, novel irradiation techniques, and better knowledge of functional and morphologic information may have created the need and optimal environment to revive the interest in IGRT. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:4 / 13
页数:10
相关论文
共 102 条
[1]   Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research [J].
Antonuk, LE .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (06) :R31-R65
[2]  
Aoki Y, 1987, Radiat Med, V5, P131
[3]   Imaging and alignment for image-guided radiation therapy [J].
Balter, James M. ;
Kessler, Marc L. .
JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (08) :931-937
[4]   A computerized remote table control for fast on-line patient repositioning: Implementation and clinical feasibility [J].
Bel, A ;
Petrascu, O ;
Van de Vondel, I ;
Coppens, L ;
Linthout, N ;
Verellen, D ;
Storme, G .
MEDICAL PHYSICS, 2000, 27 (02) :354-358
[5]   SETUP DEVIATIONS IN WEDGED PAIR IRRADIATION OF PAROTID-GLAND AND TONSILLAR TUMORS, MEASURED WITH AN ELECTRONIC PORTAL IMAGING DEVICE [J].
BEL, A ;
KEUS, R ;
VIJLBRIEF, RE ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (02) :153-159
[6]   Theragnostic imaging for radiation oncology: dose-painting by numbers [J].
Bentzen, SM .
LANCET ONCOLOGY, 2005, 6 (02) :112-117
[7]   Timeline - Radiation oncology: a century of achievements [J].
Bernier, J ;
Hall, EJ ;
Giaccia, A .
NATURE REVIEWS CANCER, 2004, 4 (09) :737-U15
[8]   A DIAGNOSTIC X-RAY FIELD VERIFICATION DEVICE FOR A 10 MV LINEAR-ACCELERATOR [J].
BIGGS, PJ ;
GOITEIN, M ;
RUSSELL, MD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (03) :635-643
[9]   FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES [J].
BIJHOLD, J ;
VANHERK, M ;
VIJLBRIEF, R ;
LEBESQUE, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1665-1679
[10]   Biologically optimized 3-dimensional in vivo predictive assay-based radiation therapy using positron emission tomography-computerized tomography Imaging [J].
Brahme, A .
ACTA ONCOLOGICA, 2003, 42 (02) :123-136