Megavoltage computed tomography - An emerging tool for image-guided radiotherapy

被引:23
作者
Hong, Theodore S. [2 ]
Welsh, James S. [1 ,2 ,3 ]
Ritter, Mark A. [2 ]
Harari, Paid M. [2 ]
Jaradat, Hazim [1 ,2 ,3 ]
Mackie, T. Rockwell [1 ,2 ,3 ]
Mehta, Minesh P. [2 ]
机构
[1] UW Canc Ctr, Wisconsin Rapids, WI 54494 USA
[2] Univ Wisconsin, Sch Med, Dept Human Oncol, Madison, WI USA
[3] Univ Wisconsin, Sch Med, Dept Med Phys, Madison, WI USA
来源
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS | 2007年 / 30卷 / 06期
关键词
megavoltage CT; image-guided radiation therapy; tomotherapy; IMRT;
D O I
10.1097/COC.0b013e3180546770
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Helical tomotherapy is a unique approach to image-guided IMRT that combines features of a linear accelerator and a CT scanner. This design allows generation of megavoltage CT (MVCT) images, which among other uses, are used to verify daily setup. In this study, we assessed the image-quality, absorbed radiation doses, and clinical practicality of MVCT from our helical tomotherapy prototype unit. Materials and Methods: Phantom studies were first performed to assess the capabilities of MVCT. Next, MVCT images from human patients prospectively enrolled on institutional review board-approved imaging and treatment protocols were analyzed. MVCT was obtained using a 4-MV beam from the University of Wisconsin helical tomotherapy prototype device. These scans were compared with conventional kilovoltage (kVCT) images from a diagnostic CT scanner. Results: MVCT images in phantoms demonstrate an ability to detect contrast differences as small as 3%. Small objects, 1.2 to 1.6 mm, were seen with good resolution. In human subjects, MVCT imaging of tumor targets and normal anatomy revealed sufficient detail for patient repositioning. MVCT imaging of metallic objects showed minimal artifact in comparison with kVCT. Patient scans were obtained in about I to 5 minutes and resulted in absorbed radiation doses of 1.5 to 3 cGy. Conclusions: MVCT is an elegant pretreatment position and setup verification tool. MVCT images of human subjects obtained from the helical tomotherapy unit showed good resolution and contrast. The high-quality three-dimensional information permits its use in day-to-day setup verification. The unique properties of MVCT also provide the potential for primary imaging of anatomic regions near metal prostheses as well as nonmedical applications. Additional investigations are underway to improve image quality, further reduce patient dose, and aid adaptive radiotherapy and dose reconstruction.
引用
收藏
页码:617 / 623
页数:7
相关论文
共 27 条
  • [1] Aoki Y, 1990, Radiat Med, V8, P107
  • [2] The university of Florida frameless high-precision stereotactic radiotherapy system
    Bova, FJ
    Buatti, JM
    Friedman, WA
    Mendenhall, WM
    Yang, CC
    Liu, C
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (04): : 875 - 882
  • [3] RADIOTHERAPEUTIC COMPUTED-TOMOGRAPHY WITH SCANNED PHOTON BEAMS
    BRAHME, A
    LIND, B
    NAFSTADIUS, P
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (01): : 95 - 101
  • [4] Automatic registration of the prostate for computed-tomography-guided radiotherapy
    Court, LE
    Dong, L
    [J]. MEDICAL PHYSICS, 2003, 30 (10) : 2750 - 2757
  • [5] Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device
    Herman, MG
    Pisansky, TM
    Kruse, JJ
    Prisciandaro, JI
    Davis, BJ
    King, BF
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (04): : 1131 - 1140
  • [6] HONG TS, 2003, RSNA 85 ANN M
  • [7] Radiation characteristics of helical tomotherapy
    Jeraj, R
    Mackie, TR
    Balog, J
    Olivera, G
    Pearson, D
    Kapatoes, J
    Ruchala, K
    Reckwerdt, P
    [J]. MEDICAL PHYSICS, 2004, 31 (02) : 396 - 404
  • [8] A feasible method for clinical delivery verification and dose reconstruction in tomotherapy
    Kapatoes, JM
    Olivera, GH
    Ruchala, KJ
    Smilowitz, JB
    Reckwerdt, PJ
    Mackie, TR
    [J]. MEDICAL PHYSICS, 2001, 28 (04) : 528 - 542
  • [9] KHAN FM, 2003, PHYS RAD THERAPY, P73
  • [10] A MEGAVOLTAGE CT SCANNER FOR RADIOTHERAPY VERIFICATION
    LEWIS, DG
    SWINDELL, W
    MORTON, EJ
    EVANS, PM
    XIAO, ZR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) : 1985 - 1999