Chemical sensors and biosensors in liquid environment based on microcantilevers with amplified quality factor

被引:157
作者
Tamayo, J [1 ]
Humphris, ADL [1 ]
Malloy, AM [1 ]
Miles, MJ [1 ]
机构
[1] Univ Bristol, HH Wills Phys Lab, Bristol BS8 1TL, Avon, England
关键词
atomic force microscopy; chemical sensor; biosensor;
D O I
10.1016/S0304-3991(00)00082-6
中图分类号
TH742 [显微镜];
学科分类号
摘要
A new technique is presented for bio/chemical sensors, based on microcantilevers, for detection in liquid environment. The low quality Factor of the cantilever in liquid is increased up to three orders of magnitude by using Q-control. This enables AC detection that is immune to the long-term drift of the DC cantilever response in liquids, and to temperature variations. This technique has been applied for the detection of ethanol in aqueous solution by using the microbalance method, and for antibody/antigen recognition by the surface stress method. The results show the feasibility and very high sensitivity of these novel devices. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:167 / 173
页数:7
相关论文
共 21 条
[1]   Analysis of the interaction mechanisms in dynamic mode SFM by means of experimental data and computer simulation [J].
Anczykowski, B ;
Cleveland, JP ;
Kruger, D ;
Elings, V ;
Fuchs, H .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1998, 66 (Suppl 1) :S885-S889
[2]   A high-sensitivity micromachined biosensor [J].
Baselt, DR ;
Lee, GU ;
Hansen, KM ;
Chrisey, LA ;
Colton, RJ .
PROCEEDINGS OF THE IEEE, 1997, 85 (04) :672-680
[3]   Environmental sensors based on micromachined cantilevers with integrated read-out [J].
Boisen, A ;
Thaysen, J ;
Jensenius, H ;
Hansen, O .
ULTRAMICROSCOPY, 2000, 82 (1-4) :11-16
[4]   A sensitive method to measure changes in the surface stress of solids [J].
Butt, HJ .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1996, 180 (01) :251-260
[5]   ADSORPTION-INDUCED SURFACE STRESS AND ITS EFFECTS ON RESONANCE FREQUENCY OF MICROCANTILEVERS [J].
CHEN, GY ;
THUNDAT, T ;
WACHTER, EA ;
WARMACK, RJ .
JOURNAL OF APPLIED PHYSICS, 1995, 77 (08) :3618-3622
[6]   Translating biomolecular recognition into nanomechanics [J].
Fritz, J ;
Baller, MK ;
Lang, HP ;
Rothuizen, H ;
Vettiger, P ;
Meyer, E ;
Güntherodt, HJ ;
Gerber, C ;
Gimzewski, JK .
SCIENCE, 2000, 288 (5464) :316-318
[7]   OBSERVATION OF A CHEMICAL-REACTION USING A MICROMECHANICAL SENSOR [J].
GIMZEWSKI, JK ;
GERBER, C ;
MEYER, E ;
SCHLITTLER, RR .
CHEMICAL PHYSICS LETTERS, 1994, 217 (5-6) :589-594
[8]   A magnetically driven oscillating probe microscope for operation in liquids [J].
Han, WH ;
Lindsay, SM ;
Jing, TW .
APPLIED PHYSICS LETTERS, 1996, 69 (26) :4111-4113
[9]  
HUMPHRIS ADL, IN PRESS LANGMUIR
[10]   A microcantilever-based alcohol vapor sensor-application and response model [J].
Jensenius, H ;
Thaysen, J ;
Rasmussen, AA ;
Veje, LH ;
Hansen, O ;
Boisen, A .
APPLIED PHYSICS LETTERS, 2000, 76 (18) :2615-2617