The importance of end-systole for optimal reconstruction protocol of coronary angiography with 16-slice multidetector computed tomography

被引:46
作者
Sanz, J
Rius, T
Kuschnir, P
Fuster, V
Goldberg, J
Ye, XY
Wisdom, P
Poon, M
机构
[1] NYU, Sch Med, Div Biostat, New York, NY USA
[2] Mt Sinai Sch Med, Marie Josee & Henry R Kravis Ctr Cardiovasc Hlth, Zena & Michael A Wiener Cardiovasc Inst, New York, NY USA
关键词
spiral computed tomography; coronary angiography; coronary vessels;
D O I
10.1097/01.rli.0000153930.34439.e4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Multidetector-row computed tomography coronary images are usually analyzed in mid-diastole (MD). Because of slow coronary motion also in end-systole (ES), we evaluated the impact on image quality of including ES images and defined an efficient reconstruction protocol. Material and Methods: In 50 coronary multidetector-row computed tomography studies, 9 reconstructions (at 10% increments of the RR interval) were graded for image quality. Multiple combinations of reconstructions were compared. Results: MD (60-70% of the RR interval) offered the best image quality. In 44% patients, the best reconstruction for greater than or equal tol coronary was found in ES (20-30%). Their heart rate was higher (68.2 +/- 9.9 bpm vs. 59.2 +/- 8.8 bpm, P = 0.0014). Combining ES and MD consistently offered superior image quality and less nonevaluable vessels than even larger numbers of diastolic reconstructions a one. A combination of 2-3 reconstructions was most efficient. Adding more reconstructions did not significantly improve results. Conclusions: Combining ES and MD reconstructions reduces nonevaluable coronary arteries, particularly with higher heart rates. A protocol including 2-3 reconstructions is the most efficient.
引用
收藏
页码:155 / 163
页数:9
相关论文
共 40 条
[11]   Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions [J].
Greess, H ;
Wolf, H ;
Baum, U ;
Lell, M ;
Pirkl, M ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2000, 10 (02) :391-394
[12]   Optimal electrocardiographically triggered phase for reducing motion artifact at electron-beam CT in the coronary artery [J].
He, S ;
Dai, RP ;
Chen, Y ;
Bai, H .
ACADEMIC RADIOLOGY, 2001, 8 (01) :48-56
[13]   Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality [J].
Herzog, C ;
Abolmaali, N ;
Balzer, JO ;
Baunach, S ;
Ackermann, H ;
Dogan, S ;
Britten, MB ;
Vogl, TJ .
EUROPEAN RADIOLOGY, 2002, 12 (11) :2670-2678
[14]  
HILLIBURTON SS, 2003, HERZ FEB, V28, P20
[15]   ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality [J].
Hong, C ;
Becker, CR ;
Huber, A ;
Schoepf, UJ ;
Ohnesorge, B ;
Knez, A ;
Brüning, R ;
Reiser, MF .
RADIOLOGY, 2001, 220 (03) :712-717
[16]   Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation [J].
Jakobs, TF ;
Becker, CR ;
Ohnesorge, B ;
Flohr, T ;
Suess, C ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1081-1086
[17]   Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart [J].
Jung, B ;
Mahnken, AH ;
Stargardt, A ;
Simon, J ;
Flohr, TG ;
Schaller, S ;
Koos, R ;
Günther, RW ;
Wildberger, JE .
EUROPEAN RADIOLOGY, 2003, 13 (12) :2560-2566
[18]   Impact of bulk cardiac motion on right coronary MR angiography and vessel wall Imaging [J].
Kim, WY ;
Stuber, M ;
Kissinger, KV ;
Andersen, NT ;
Manning, WJ ;
Botnar, RM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) :383-390
[19]   Coronary magnetic resonance angiography for the detection of coronary stenoses [J].
Kim, WY ;
Danias, PG ;
Stuber, M ;
Flamm, SD ;
Plein, S ;
Nagel, E ;
Langerak, SE ;
Weber, OM ;
Pedersen, EM ;
Schmidt, M ;
Botnar, RM ;
Manning, WJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (26) :1863-1869
[20]   Subsecond multi-slice computed tomography: basics and applications [J].
Klingenbeck-Regn, K ;
Schaller, S ;
Flohr, T ;
Ohnesorge, B ;
Kopp, AF ;
Baum, U .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (02) :110-124