Evaluation of the ordered subset convex algorithm for cone-beam CT

被引:24
作者
Kole, JS
Beekman, FJ
机构
[1] Univ Med Ctr Utrecht, Dept Nucl Med, Image Sci Inst, NL-3584 CG Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Pharmacol & Anat, Rudolf Magnus Inst Neurosci, NL-3584 CG Utrecht, Netherlands
关键词
D O I
10.1088/0031-9155/50/4/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Statistical methods for image reconstruction such as maximum likelihood expectation maximization (ML-EM) are more robust and flexible than analytical inversion methods and allow for accurate modelling of the photon transport and noise. Statistical reconstruction is prohibitively slow when applied to clinical x-ray cone-beam CT due to the large data sets and the high number of iterations required for reconstructing high resolution images. One way to reduce the reconstruction time is to use ordered subsets of projections during the iterations, which has been successfully applied to fan-beam x-ray CT. In this paper, we quantitatively analyse the use of ordered subsets in concert with the convex algorithm for cone-beam x-ray CT reconstruction, for the case of circular acquisition orbits. We focus on the reconstructed image accuracy of a 3D head phantom. Acceleration factors larger than 300 were obtained with errors smaller than 1%, with the preservation of signal-to-noise ratio. Pushing the acceleration factor towards 600 by using an increasing number of subsets increases the reconstruction error LIP to 5% and significantly increases noise. The results indicate that the use of ordered subsets can be extremely useful for cone-beam x-ray CT.
引用
收藏
页码:613 / 623
页数:11
相关论文
共 28 条
[1]  
Beekman FJ, 1998, J NUCL MED, V39, P1996
[2]   Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation [J].
Beekman, FJ ;
Kamphuis, C ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (04) :491-499
[3]   Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation [J].
Beekman, FJ ;
de Jong, HWAM ;
van Geloven, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (08) :867-877
[4]   Ordered subset reconstruction for x-ray CT [J].
Beekman, FJ ;
Kamphuis, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (07) :1835-1844
[5]   Comparison of 3-D maximum a posteriori and filtered backprojection algorithms for high-resolution animal imaging with microPET [J].
Chatziioannou, A ;
Qi, J ;
Moore, A ;
Annala, A ;
Nguyen, K ;
Leahy, R ;
Cherry, SR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) :507-512
[6]   Experimental validation of a rapid Monte Carlo based micro-CT simulator [J].
Colijn, AP ;
Zbijewski, W ;
Sasov, A ;
Beekman, FJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (18) :4321-4333
[7]   Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm [J].
De Man, B ;
Nuyts, J ;
Dupont, P ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) :977-981
[8]   Statistical image reconstruction for polyenergetic X-ray computed tomography [J].
Elbakri, IA ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (02) :89-99
[9]   Ordered subsets algorithms for transmission tomography [J].
Erdogan, H ;
Fessler, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :2835-2851
[10]  
Fessler J. A., 2000, Handb. Med. Imaging, V2, P1, DOI DOI 10.1117/3.831079