Biosensor for total cholesterol estimation using N-(2-aminoethyl)-3-aminopropyltrimethoxysilane self-assembled monolayer

被引:22
作者
Arya, Sunil K.
Datta, Monika
Singh, S. P.
Malhotra, Bansi D.
机构
[1] Natl Phys Lab, Biomol Elect & Conducting Polymer Res Grp, New Delhi 110012, India
[2] Univ Delhi, Dept Chem, New Delhi 110007, India
关键词
cholesterol oleate; N-(2-Aminoethyl)-3-aminopropyltrimethoxysilane (AEAPTS); self-assembled monolayer (SAM); cyclic voltammetry; biosensor;
D O I
10.1007/s00216-007-1655-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cholesterol oxidase (ChOx), cholesterol esterase (ChEt), and horseradish peroxidase (HRP) have been co-immobilized covalently on a self-assembled monolayer (SAM) of N-(2-aminoethyl)-3-aminopropyltrimethoxysilane (AEAPTS) deposited on an indium-tin-oxide (ITO) glass surface. These enzyme-modified (ChOx-ChEt-HRP/AEAPTS/ITO) biosensing electrodes have been used to estimate cholesteryl oleate from 10 to 500 mg dL(-1). The sensitivity, K-m value, and shelf-life of these ChEt-ChOx-HRP/AEAPTS/ITO biosensing electrodes have been found to be 124 nA mg(-1) dL, 95.098 mg dL(-1) (1.46 mmol L-1), and ten weeks, respectively. The ChEt-ChOx-HRP/AEAPTS/ITO bio-electrodes have been used to estimate total cholesterol in serum samples.
引用
收藏
页码:2235 / 2242
页数:8
相关论文
共 43 条
[1]   Sensitive estimation of total cholesterol in blood using Au nanowires based micro-fluidic platform [J].
Aravamudhan, Shyam ;
Kumar, Arun ;
Mohapatra, Shyam ;
Bhansali, Shekhar .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10) :2289-2294
[2]   Cholesterol biosensor based on N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane self-assembled monolayer [J].
Arya, Sunil K. ;
Prusty, Arun K. ;
Singh, S. P. ;
Solanki, Pratima R. ;
Pandey, Manoj K. ;
Datta, Monika ;
Malhotra, Bansi D. .
ANALYTICAL BIOCHEMISTRY, 2007, 363 (02) :210-218
[3]   Poly-(3-hexylthiophene) self-assembled monolayer based cholesterol biosensor using surface plasmon resonance technique [J].
Arya, Sunil K. ;
Solanki, Pratima R. ;
Singh, S. P. ;
Kaneto, K. ;
Pandey, Manoj K. ;
Datta, Monika ;
Malhotra, Bansi D. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) :2516-2524
[4]   Application of octadecanethiol self-assembled monolayer to cholesterol biosensor based on surface plasmon resonance technique [J].
Arya, Sunil K. ;
Solanki, Pratima R. ;
Singh, Ravindra P. ;
Pandey, Manoj K. ;
Datta, Monika ;
Malhotra, Bansi D. .
TALANTA, 2006, 69 (04) :918-926
[5]   Stabilization of immobilized glucose oxidase against thermal inactivation by silanization for biosensor applications [J].
Babu, VRS ;
Kumar, MA ;
Karanth, NG ;
Thakur, MS .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (10) :1337-1341
[6]   Development of cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on oxygen electrode for the determination of total cholesterol in food samples [J].
Basu, Anjan Kumar ;
Chattopadhyay, Parimal ;
Roychoudhuri, Utpal ;
Chakraborty, Runu .
BIOELECTROCHEMISTRY, 2007, 70 (02) :375-379
[7]   An electrochemical multienzymatic biosensor for determination of cholesterol [J].
Bongiovanni, C ;
Ferri, T ;
Poscia, A ;
Varalli, M ;
Santucci, R ;
Desideri, A .
BIOELECTROCHEMISTRY, 2001, 54 (01) :17-22
[8]   Self-assembled monolayers of thiols on gold electrodes for bioelectrochemistry and biosensors [J].
Dong, SJ ;
Li, JH .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1997, 42 (01) :7-13
[9]   Design of an interference-free cholesterol amperometric biosensor based on the electrosynthesis of polymeric films of diaminonaphthalene isomers [J].
García-Ruiz, E ;
Vidal, JC ;
Aramendía, MT ;
Castillo, JR .
ELECTROANALYSIS, 2004, 16 (06) :497-504
[10]   Application of conducting polymers to biosensors [J].
Gerard, M ;
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (05) :345-359