Helical tomotherapy: Image guidance and adaptive dose guidance

被引:23
作者
Tome, Wolfgang A. [1 ]
Jaradat, Hazim A. [1 ]
Nelson, Ian A. [1 ]
Ritter, Mark A. [1 ]
Mehta, Minesh P. [1 ]
机构
[1] Univ Wisconsin, Sch Med Publ Hlth, Dept Human Oncol, Madison, WI 53706 USA
来源
IMRT, IGRT, SBRT: ADVANCES IN THE TREATMENT PLANNING AND DELIVERY OF RADIOTHERAPY | 2007年 / 40卷
关键词
D O I
10.1159/000106034
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Helical tomotherapy is a volumetric image-guided, fully dynamic, intensity-modulated radiation therapy (IMRT) delivery system. The daily use of its pretreatment megavoltage (MV) CT imaging for patient setup verification allows one to correct for interfraction setup error. This is a primary requirement for the accurate delivery of complex IMRT treatment plans, which give differential radiation doses to various target volumes while conformally avoiding normal critical structures. In particular, image guidance using MV CT allows for direct target position verification with the patient in the actual treatment position just prior to therapy delivery. Moreover, since helical MV CT imaging is a slow CT imaging technique, it allows for the encoding of target motion in the resulting MV CT data set, and therefore the pretreatment verification of a motion envelope defined from four-dimensional CT Copyright (C) 2007 S. Karger AG, Basel.
引用
收藏
页码:162 / 178
页数:17
相关论文
共 22 条
[1]   Clinical helical tomotherapy commissioning dosimetry [J].
Balog, J ;
Olivera, G ;
Kapatoes, J .
MEDICAL PHYSICS, 2003, 30 (12) :3097-3106
[2]   Benchmarking beam alignment for a clinical helical tomotherapy device [J].
Balog, J ;
Mackie, TR ;
Pearson, D ;
Hui, S ;
Paliwal, B ;
Jeraj, R .
MEDICAL PHYSICS, 2003, 30 (06) :1118-1127
[3]   Multileaf collimator interleaf transmission [J].
Balog, JP ;
Mackie, TR ;
Wenman, DL ;
Glass, M ;
Fang, G ;
Pearson, D .
MEDICAL PHYSICS, 1999, 26 (02) :176-186
[4]   Characterization of the output for helical delivery of intensity modulated slit beams [J].
Balog, JP ;
Mackie, TR ;
Reckwerdt, P ;
Glass, M ;
Angelos, L .
MEDICAL PHYSICS, 1999, 26 (01) :55-64
[5]   Quality assurance of a helical tomotherapy machine [J].
Fenwick, JD ;
Tomé, WA ;
Jaradat, HA ;
Hui, SK ;
James, JA ;
Balog, JP ;
DeSouza, CN ;
Lucas, DB ;
Olivera, GH ;
Mackie, TR ;
Paliwal, BR .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (13) :2933-2953
[6]   Modelling simple helically delivered dose distributions [J].
Fenwick, JD ;
Tomé, WA ;
Kissick, MW ;
Mackie, TR .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (07) :1505-1517
[7]   Pelvic nodal dose escalation with prostate hypofractionation using conformal avoidance defined (H-CAD) intensity modulated radiation therapy [J].
Hong, Theodore S. ;
Tome, Wolfgang A. ;
Jaradat, Hazim ;
Raisbeck, Bridget M. ;
Ritter, Mark A. .
ACTA ONCOLOGICA, 2006, 45 (06) :717-727
[8]   PHYSICAL PERFORMANCE-CHARACTERISTICS OF SPIRAL CT SCANNING [J].
KALENDER, WA ;
POLACIN, A .
MEDICAL PHYSICS, 1991, 18 (05) :910-915
[9]   On the accuracy and effectiveness of dose reconstruction for tomotherapy [J].
Kapatoes, JM ;
Olivera, GH ;
Balog, JP ;
Keller, H ;
Reckwerdt, PJ ;
Mackie, TR .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04) :943-966
[10]   The helical tomotherapy thread effect [J].
Kissick, MW ;
Fenwick, J ;
James, JA ;
Jerai, R ;
Kapatoes, JM ;
Keller, H ;
Mackie, TR ;
Olivera, G ;
Soisson, ET .
MEDICAL PHYSICS, 2005, 32 (05) :1414-1423