Microfabricated PDMS multichannel emitter for electrospray ionization mass spectrometry

被引:92
作者
Kim, JS [1 ]
Knapp, DR [1 ]
机构
[1] Med Univ S Carolina, Dept Pharmacol, Charleston, SC 29425 USA
基金
美国国家科学基金会;
关键词
D O I
10.1016/S1044-0305(01)00219-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel microfabricated multichannel emitter for electrospray ionization mass spectrometry (ESI-MS) was implemented with polydimethylsiloxane (PDMS) using a soft lithography technique. The emitters are formed as electrospray tips along a thin membrane on the edge of the device with channels of 100 mum X 30 mum dimensions. The electrospray performance of the PDMS emitters for a single channel device and a four channel device interfaced with a time-of-flight mass spectrometer was evaluated for detecting the molecular weight of reference peptides (angiotensin I and bradykinin). The emitters were durable at the flow rate of 1-20 muL min-l for more than 30 h of continuous electrospray with limit of detection of 1 muM (S/N 18). This microfabrication method for a PDMS multichannel emitter as an integral part of a microfluidic device will facilitate development of more complex microfluidic analysis systems using ESI-MS. (C) 2001 American Society for Mass Spectrometry.
引用
收藏
页码:463 / 469
页数:7
相关论文
共 28 条
[11]   A micromachined chip-based electrospray source for mass spectrometry [J].
Licklider, L ;
Wang, XQ ;
Desai, A ;
Tai, YC ;
Lee, TD .
ANALYTICAL CHEMISTRY, 2000, 72 (02) :367-375
[12]   Development of multichannel devices with an array of electrospray tips far high-throughput mass spectrometry [J].
Liu, HH ;
Felten, C ;
Xue, QF ;
Zhang, BL ;
Jedrzejewski, P ;
Karger, BL ;
Foret, F .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3303-3310
[13]  
McDonald JC, 2000, ELECTROPHORESIS, V21, P27, DOI 10.1002/(SICI)1522-2683(20000101)21:1<27::AID-ELPS27>3.0.CO
[14]  
2-C
[15]   Analytical microdevices for mass spectrometry [J].
Oleschuk, RD ;
Harrison, DJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (06) :379-388
[16]  
Pinto DM, 2000, ELECTROPHORESIS, V21, P181, DOI 10.1002/(SICI)1522-2683(20000101)21:1<181::AID-ELPS181>3.0.CO
[17]  
2-Q
[18]   Rapid prototyping of complex structures with feature sizes larger than 20 mu m [J].
Qin, D ;
Xia, YN ;
Whitesides, GM .
ADVANCED MATERIALS, 1996, 8 (11) :917-&
[19]   MICROFABRICATED CHEMICAL MEASUREMENT SYSTEMS [J].
RAMSEY, JM ;
JACOBSON, SC ;
KNAPP, MR .
NATURE MEDICINE, 1995, 1 (10) :1093-1096
[20]   Generating electrospray from microchip devices using electroosmotic pumping [J].
Ramsey, RS ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1174-1178