Rapid Microarray Detection of DNA and Proteins in Microliter Volumes with Surface Plasmon Resonance Imaging Measurements

被引:28
作者
Seefeld, Ting Hu [1 ]
Zhou, Wen-Juan [1 ]
Corn, Robert M. [1 ]
机构
[1] Univ Calif Irvine, Dept Chem, Irvine, CA 92697 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
RNA APTAMER MICROARRAYS; DIFFRACTION GRATINGS; FABRICATION; MICRORNAS; KINETICS; ARRAYS; ADSORPTION; EXPRESSION; BIOMARKERS; DISEASE;
D O I
10.1021/la200649n
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A four-chamber microfluidic biochip is fabricated for the rapid detection of multiple proteins and nucleic acids from microliter volume samples with the technique of surface plasmon resonance imaging (SPRI). The 18 mm x 18 mm biochip consists of four 3 mu L microfluidic chambers attached to an SF10 glass substrate, each of which contains three individually addressable SPRI gold thin film microarray elements. The 12-element (4 x 3) SPRI microarray consists of gold thin film spots (1 mm(2) area; 45 nm thickness), each in individually addressable 0.5 mu L volume microchannels. Microarrays of single-stranded DNA and RNA (ssDNA and ssRNA, respectively) are fabricated by either chemical and/or enzymatic attachment reactions in these microchannels; the SPRI microarrays are then used to detect femtomole amounts (nanomolar concentrations) of DNA and proteins (ssDNA binding protein and thrombin via aptamer-protein bioaffinity interactions). Microarrays of ssRNA microarray elements are also used for the ultrasensitive detection of zeptomole amounts (femtomolar concentrations) of DNA via the technique of RNase H-amplified SPRI. Enzymatic removal of ssRNA from the surface due to the hybridization adsorption of target ssDNA is detected as a reflectivity decrease in the SPR imaging measurements. The observed reflectivity loss is proportional to the log of the target ssDNA concentration with a detection limit of 10 fM or 30 zeptomoles (18 000 molecules). This enzymatic amplified ssDNA detection method is not limited by diffusion of ssDNA to the interface, and thus is extremely fast, requiring only 200 s in the microliter volume format.
引用
收藏
页码:6534 / 6540
页数:7
相关论文
共 45 条
[1]   Stool DNA-based colorectal cancer detection: Finding the needle in the haystack [J].
Atkin, W ;
Martin, JP .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2001, 93 (11) :798-799
[2]   Aptamers come of age - at last [J].
Bunka, David H. J. ;
Stockley, Peter G. .
NATURE REVIEWS MICROBIOLOGY, 2006, 4 (08) :588-596
[3]   Using protein-DNA chimeras to detect and count small numbers of molecules [J].
Burbulis, I ;
Yamaguchi, K ;
Gordon, A ;
Carlson, R ;
Brent, R .
NATURE METHODS, 2005, 2 (01) :31-37
[4]   MicroRNA signatures in human cancers [J].
Calin, George A. ;
Croce, Carlo M. .
NATURE REVIEWS CANCER, 2006, 6 (11) :857-866
[5]   Fabrication of DNA Microarrays with Poly(L-glutamic acid) Monolayers on Gold Substrates for SPR Imaging Measurements [J].
Chen, Yulin ;
Nguyen, Anh ;
Niu, Lifang ;
Corn, Robert M. .
LANGMUIR, 2009, 25 (09) :5054-5060
[6]   SITE SPECIFIC ENZYMATIC CLEAVAGE OF RNA [J].
DONISKELLER, H .
NUCLEIC ACIDS RESEARCH, 1979, 7 (01) :179-192
[7]   Attomole microarray detection of MicroRNAs by nanoparticle-amplified SPR imaging measurements of surface polyadenylation reactions [J].
Fang, Shiping ;
Lee, Hye Jin ;
Wark, Alastair W. ;
Corn, Robert M. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (43) :14044-14046
[8]  
Gedig ET, 2008, HANDBOOK OF SURFACE PLASMON RESONANCE, P173
[9]   Attomole Detection of Mesophilic DNA Polymerase Products by Nanoparticle-Enhanced Surface Plasmon Resonance Imaging on Glassified Gold Surfaces [J].
Gifford, Lida K. ;
Sendroiu, Iuliana E. ;
Corn, Robert M. ;
Luptak, Andrej .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2010, 132 (27) :9265-9267
[10]   Enzymatically amplified surface plasmon resonance imaging method using RNase H and RNA microarrays for the ultrasensitive detection of nucleic acids [J].
Goodrich, TT ;
Lee, HJ ;
Corn, RM .
ANALYTICAL CHEMISTRY, 2004, 76 (21) :6173-6178