OBJECTIVE. The purpose of this study was to determine the relative diagnostic accuracy of radiologists in the interpretation of CT scans using a computer workstation in comparison with using film. MATERIALS AND METHODS. Four board-certified radiologists with extensive soft-copy experience interpreted 117 CT scans in four anatomic regions using films displayed on an alternator and images displayed on a four-monitor workstation. The radiologists were asked to interpret the scans in their usual fashion and were aware that both the time required to review the study and the accuracy of the reports were being assessed. The radiologists' diagnostic impressions were compared with those of a consensus panel and scored for accuracy. RESULTS. Soft-copy interpretation using computer workstations was found to produce statistically significant improvement in combined measurements of sensitivity, specificity, and overall accuracy for chest, brain, and chest-abdominal CT scans compared with film interpretation. CONCLUSION. PACS (picture archiving and communication system) offers radiologists the potential for improved accuracy in CT interpretation compared with traditional film-based interpretation.
引用
收藏
页码:1407 / 1410
页数:4
相关论文
共 21 条
[1]  
Beard D V, 1994, J Digit Imaging, V7, P69
[2]   INTERPRETATION TIME OF SERIAL CHEST CT EXAMINATIONS WITH STACKED-METAPHOR WORKSTATION VERSUS FILM ALTERNATOR [J].
BEARD, DV ;
MOLINA, PL ;
MULLER, KE ;
DENELSBECK, KM ;
HEMMINGER, BM ;
PERRY, JR ;
BRAEUNING, MP ;
GLUECK, DH ;
BIDGOOD, WD ;
MAURO, M ;
SEMELKA, RC ;
WILLMS, AS ;
WARSHAUER, D ;
PISANO, ED .
RADIOLOGY, 1995, 197 (03) :753-758
[3]   INTERPRETATION OF CT STUDIES - SINGLE-SCREEN WORKSTATION VERSUS FILM ALTERNATOR [J].
BEARD, DV ;
HEMMINGER, BM ;
PERRY, JR ;
MAURO, MA ;
MULLER, KE ;
WARSHAUER, DM ;
SMITH, MA ;
ZITO, AJ .
RADIOLOGY, 1993, 187 (02) :565-569
[4]   EVALUATION OF A PACS WORKSTATION FOR ASSESSMENT OF BODY CT STUDIES [J].
BERBAUM, KS ;
FRANKEN, EA ;
HONDA, H ;
MCGUIRE, C ;
WEIS, RR ;
BARLOON, T .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (05) :853-858
[5]   DISPLAY OF CT STUDIES ON A 2-SCREEN ELECTRONIC WORKSTATION VERSUS A FILM PANEL ALTERNATOR - SENSITIVITY AND EFFICIENCY AMONG RADIOLOGISTS [J].
FOLEY, WD ;
JACOBSON, DR ;
TAYLOR, AJ ;
GOODMAN, LR ;
STEWART, ET ;
GURNEY, JW ;
STROKA, D .
RADIOLOGY, 1990, 174 (03) :769-773
[6]   Processes involved in reading imaging studies: Workflow analysis and implications for workstation development [J].
Gay, SB ;
Sobel, AH ;
Young, LQ ;
Dwyer, SJ .
JOURNAL OF DIGITAL IMAGING, 1997, 10 (01) :40-45
[7]   PACS in sonography: Accuracy of interpretation using film compared with monitor display [J].
Hertzberg, BS ;
Kliewer, MA ;
Paulson, EK ;
Sheafor, DH ;
Freed, KS ;
Bowie, JD ;
Carroll, BA ;
DeLong, DH ;
Nelson, RC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (05) :1175-1179
[8]   ANALYSIS OF THE COST-EFFECTIVENESS OF PACS [J].
HILSENRATH, PE ;
SMITH, WL ;
BERBAUM, KS ;
FRANKEN, EA ;
OWEN, DA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (01) :177-180
[9]   CLINICAL-EVALUATION OF NEWLY DEVELOPED CRT VIEWING STATION - CT READING AND OBSERVERS PERFORMANCE [J].
HIROTA, H ;
SHIMAMOTO, K ;
YAMAKAWA, K ;
ISHIGAKI, T ;
TAKAHASHI, Y ;
SUGIYAMA, N ;
NISHIHARA, E ;
TANI, Y .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1995, 19 (03) :281-285
[10]   Reliability of soft-copy versus hard-copy interpretation of emergency department radiographs: A prototype study [J].
Kundel, HL ;
Polansky, M ;
Dalinka, MK ;
Choplin, RH ;
Gefter, WB ;
Kneelend, JB ;
Miller, WT ;
Miller, WT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (03) :525-528