Dosimetric effect of respiration-gated beam on IMRT delivery

被引:31
作者
Duan, J [1 ]
Shen, S [1 ]
Fiveash, JB [1 ]
Brezovich, IA [1 ]
Popple, RA [1 ]
Pareek, PN [1 ]
机构
[1] Univ Alabama, Dept Radiat Oncol, Birmingham, AL 35233 USA
关键词
gated IMRT; respiratory gating; IMRT; dynamic wedge; dosimetric effect;
D O I
10.1118/1.1592017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intensity modulated radiation therapy (IMRT) with a dynamic multileaf collimator (DMLC) requires synchronization of DMLC leaf motion with dose delivery. A delay in DMLC communication is known to cause leaf lag and lead to dosimetric errors. The errors may be exacerbated by gated operation. The purpose of this study was to investigate the effect of leaf lag on the accuracy of doses delivered in gated IMRT. We first determined the effective leaf delay time by measuring the dose in a stationary phantom delivered by wedge-shaped fields. The wedge fields were generated by a DMLC at various dose rates. The so determined delay varied from 88.3 to 90.5 ms. The dosimetric effect of this delay on gated IMRT was studied by delivering wedge-shaped and clinical IMRT fields to moving and stationary phantoms at dose rates ranging from 100 to 600 MU/min, with and without gating. Respiratory motion was simulated by a linear sinusoidal motion of the phantom. An ionization chamber and films were employed for absolute dose and 2-D dose distribution measurements. Discrepancies between gated and nongated delivery to the stationary phantom were observed in both absolute dose and 2-D dose distribution measurements. These discrepancies increased monotonically with dose rate and frequency of beam interruptions, and could reach 3.7% of the total dose delivered to a 0.6 cm(3) ion chamber. Isodose lines could be shifted by as much as 3 mm. The results are consistent with the explanation that beam hold-offs in gated delivery allowed the lagging leaves to catch up with the delivered monitor units each time that the beam was interrupted. Low dose rates, slow leaf speeds and low frequencies of beam interruptions reduce the effect of this delay-and-catch-up cycle. For gated IMRT it is therefore important to find a good balance between the conflicting requirements of rapid dose delivery and delivery accuracy. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:2241 / 2252
页数:12
相关论文
共 28 条
[11]   Intensity modulation to improve dose uniformity with tangential breast radiotherapy: Initial clinical experience [J].
Kestin, LL ;
Sharpe, MB ;
Frazier, RC ;
Vicini, FA ;
Yan, D ;
Matter, RC ;
Martinez, AA ;
Martinez, AA ;
Wong, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05) :1559-1568
[12]   Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center [J].
Kubo, HD ;
Len, PM ;
Minohara, S ;
Mostafavi, H .
MEDICAL PHYSICS, 2000, 27 (02) :346-353
[13]   Compatibility of Varian 2100C gated operations with enhanced dynamic wedge and IMRT dose delivery [J].
Kubo, HD ;
Wang, LL .
MEDICAL PHYSICS, 2000, 27 (08) :1732-1738
[14]  
Litzenberg Dale W, 2002, J Appl Clin Med Phys, V3, P63, DOI 10.1120/1.1449362
[15]   Incorporation of realistic delivery limitations into dynamic MLC treatment delivery [J].
Litzenberg, DW ;
Moran, JM ;
Fraass, BA .
MEDICAL PHYSICS, 2002, 29 (05) :810-820
[16]   Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy [J].
LoSasso, T ;
Chui, CS ;
Ling, CC .
MEDICAL PHYSICS, 1998, 25 (10) :1919-1927
[17]   A technique for the quantitative evaluation of dose distributions [J].
Low, DA ;
Harms, WB ;
Mutic, S ;
Purdy, JA .
MEDICAL PHYSICS, 1998, 25 (05) :656-661
[18]   Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy [J].
Low, DA ;
Sohn, JW ;
Klein, EE ;
Markman, J ;
Mutic, S ;
Dempsey, JF .
MEDICAL PHYSICS, 2001, 28 (05) :752-756
[19]  
Mageras G S, 2001, J Appl Clin Med Phys, V2, P191, DOI 10.1120/1.1409235
[20]   Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer [J].
Nehmeh, SA ;
Erdi, YE ;
Ling, CC ;
Rosenzweig, KE ;
Squire, OD ;
Braban, LE ;
Ford, E ;
Sidhu, K ;
Mageras, GS ;
Larson, SM ;
Humm, JL .
MEDICAL PHYSICS, 2002, 29 (03) :366-371