Reduced radiation for adult thoracic CT - A practical approach

被引:3
作者
Gamsu, G [1 ]
Held, BT [1 ]
Czum, JM [1 ]
机构
[1] Weill Cornell Med Coll, Dept Radiol, New York, NY 10021 USA
关键词
thoracic computed tomography; radiation reduction; helical CT; thoracic imaging;
D O I
10.1097/00005382-200404000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine whether radiation dose to patients can be reduced for clinical thoracic CT scans without loss of diagnostic information. Materials and Methods: One hundred consecutive patients having clinical CT examinations of the thorax were included. The patients were divided into 4 groups, and the mAs setting determined from the patient's weight as follows (max. 300 and min. 100 mAs): group 1: mAs = weight in lbs. rounded to the next multiple of 10, plus 30 (mAs = wt(R) + 30); group 2: mAs = weight rounded to the next multiple of 10 (mAs = wt(R)); group 3: mAs weight rounded to the next multiple of 10, minus 20 (mAs = wt(R) - 20); group 4: mAs weight rounded to the next multiple of 10, minus 30 (mAs = wt(R) - 30). The neck, mediastinum, lungs, and upper abdomen were assessed for quality on a 4 point scale. Results: Only at the lowest mAs levels did we see some degradation of image quality in the lower neck with an increase in streak artifacts. The other body regions all showed good or excellent image quality. Conclusions: Radiation dosage can be reduced by more than half without loss of diagnostic quality, using this simple formula: mAs = weight in lbs. rounded to the next multiple of 10 minus 30 (mAs = wt(R) - 30).
引用
收藏
页码:93 / 97
页数:5
相关论文
共 15 条
[1]   Thoracic CT technique in children [J].
Brody, AS .
JOURNAL OF THORACIC IMAGING, 2001, 16 (04) :259-268
[2]   USAGE OF DIAGNOSTIC-IMAGING PROCEDURES - A NATIONWIDE HOSPITAL STUDY [J].
BUNGE, RE ;
HERMAN, CL .
RADIOLOGY, 1987, 163 (02) :569-573
[3]   Spiral CT of the abdomen: Weight-adjusted dose reduction. [J].
Coppenrath, E ;
Schmid, C ;
Brandl, R ;
Szeimies, U ;
Hahn, K .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (01) :52-56
[4]   Lung cancer screening: Minimum tube current required for helical CT [J].
Itoh, S ;
Ikeda, M ;
Arahata, S ;
Kodaira, T ;
Isomura, T ;
Kato, T ;
Yamakawa, K ;
Maruyama, K ;
Ishigaki, T .
RADIOLOGY, 2000, 215 (01) :175-183
[5]   Image quality and dose in computed tomography [J].
Jurik, AG ;
Jessen, KA ;
Hansen, J .
EUROPEAN RADIOLOGY, 1997, 7 (01) :77-81
[6]   GT OF THE CHEST - MINIMAL TUBE CURRENT REQUIRED FOR GOOD IMAGE QUALITY WITH THE LEAST RADIATION-DOSE [J].
MAYO, JR ;
HARTMAN, TE ;
LEE, KS ;
PRIMACK, SL ;
VEDAL, S ;
MULLER, NL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (03) :603-607
[7]   USE OF RADIOLOGY IN UNITED-STATES GENERAL SHORT-TERM HOSPITALS - 1980-1990 [J].
METTLER, FA ;
BRIGGS, JE ;
CARCHMAN, R ;
ALTOBELLI, KK ;
HART, BL ;
KELSEY, CA .
RADIOLOGY, 1993, 189 (02) :377-380
[8]   LOW-DOSE CT OF THE LUNGS - PRELIMINARY-OBSERVATIONS [J].
NAIDICH, DP ;
MARSHALL, CH ;
GRIBBIN, C ;
ARAMS, RS ;
MCCAULEY, DI .
RADIOLOGY, 1990, 175 (03) :729-731
[9]   Radiation exposures to patients from CT: Reality, public perception, and policy [J].
Nickoloff, EL ;
Alderson, PO .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (02) :285-287
[10]   DETERMINATIONS OF ORGAN DOSES AND EFFECTIVE DOSE EQUIVALENTS FROM COMPUTED TOMOGRAPHIC EXAMINATION [J].
NISHIZAWA, K ;
MARUYAMA, T ;
TAKAYAMA, M ;
OKADA, M ;
HACHIYA, J ;
FURUYA, Y .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (757) :20-28