Comparison of sixty-four-slice multidetector computed tomographic coronary angiography to coronary angiography with intravascular ultrasound for the detection of transplant vasculopathy

被引:73
作者
Gregory, Shawn A.
Ferencik, Maros
Achenbach, Stephan
Yeh, Robert W.
Hoffmann, Udo
Inglessis, Ignacio
Cury, Ricardo C.
Nieman, Koen
McNulty, Iris A.
Laffan, Josephine A.
Pomerantsev, Eugene V.
Brady, Thomas J.
Pomerantsev, Eugene V.
Brady, Thomas J.
Semigran, Marc J.
Jang, Ik-Kyung [1 ]
机构
[1] Massachusetts Gen Hosp, Div Cardiol, Dept Med, Boston, MA 02114 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol, Boston, MA 02114 USA
[3] Univ Erlangen Nurnberg, Dept Med 2, Erlangen, Germany
[4] Harvard Univ, Sch Med, Boston, MA 02114 USA
关键词
D O I
10.1016/j.amjcard.2006.04.027
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary allograft vasculopathy (CAV) is the most important limitation to long-term survival in adult heart transplant recipients and is difficult to detect without intravascular ultrasound (IVUS). We systematically evaluated the image quality of 64-slice multidetector computed tomographic (MDCT) coronary angiography in heart transplant recipients and tested the hypothesis that this modality is comparable to invasive coronary angiography with IVUS for the detection of CAV. Heart transplant recipients (n = 20) underwent invasive coronary angiography with IVUS and MDCT coronary angiography with a 64-slice scanner. Images were systematically analyzed for image quality and the presence of CAV. In addition, multidetector computed tomography and quantitative coronary angiography were used to measure lumen diameters at prespecified locations., Image quality analysis showed that, despite high mean heart rates (77 +/- 7 beats/min) and body mass index (29.5 +/- 5.3 kg/m(2)), 83% of coronary segments were graded as of excellent or good image quality. On average, 95 +/- 9% of the overall visualized length of the coronary arteries was imaged without motion artifacts' and the mean contrast-to-noise ratio was 11.3 +/- 4.6. Compared with IVUS, multidetector computed tomography had a sensitivity of 70%, specificity of 92%, positive predictive value of 89%, and negative predictive value of 77% for the detection of CAV. MDCT vessel diameter measurements correlated well with those obtained from quantitative coronary angiography (R-2 = 0.89). In conclusion, 64-slice multidetector computed tomography provides good to excellent image quality in heart transplant recipients and has moderate to excellent test characteristics for the detection of CAV. Further, MDCT measurements of lumen diameters correlated well with quantitative coronary angiography. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:877 / 884
页数:8
相关论文
共 30 条
[1]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[2]   Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography [J].
Achenbach, S ;
Giesler, T ;
Ropers, D ;
Ulzheimer, S ;
Anders, K ;
Wenkel, E ;
Pohle, K ;
Kachelriess, M ;
Derlien, H ;
Kalender, WA ;
Daniel, WG ;
Bautz, W ;
Baum, U .
INVESTIGATIVE RADIOLOGY, 2003, 38 (02) :119-128
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]   Comparison of the degree of coronary stenoses by multidetector computed tomography versus by quantitative coronary angiography [J].
Cury, RC ;
Pomerantsev, EV ;
Ferencik, M ;
Hoffmann, U ;
Nieman, K ;
Moselewski, F ;
Abbara, S ;
Jang, IK ;
Brady, TJ ;
Achenbach, S .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (06) :784-787
[5]   Quantitative parameters of image quality in 64-slice computed tomography angiography of the coronary arteries [J].
Ferencik, M ;
Nomura, CH ;
Maurovich-Horvat, P ;
Hoffmann, U ;
Pena, AJ ;
Cury, RC ;
Abbara, S ;
Nieman, K ;
Fatima, U ;
Achenbach, S ;
Brady, TJ .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :373-379
[6]   Quantitative parameters of image quality in multidetector spiral computed tomographic coronary imaging with submillimeter collimation [J].
Ferencik, M ;
Moselewski, F ;
Ropers, D ;
Hoffmann, U ;
Baum, U ;
Anders, K ;
Pomerantsev, EV ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (11) :1257-1262
[7]   Performance evaluation of a 64-slice CT system with z-flying focal spot [J].
Flohr, T ;
Stierstorfer, K ;
Raupach, R ;
Ulzheimer, S ;
Bruder, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12) :1803-1810
[8]   Noninvasive coronary angiography with 16-detector row CT: Effect of heart rate [J].
Hoffmann, MHK ;
Shi, HS ;
Manzke, R ;
Schmid, FT ;
De Vries, L ;
Grass, M ;
Brambs, HR ;
Aschoff, AJ .
RADIOLOGY, 2005, 234 (01) :86-97
[9]   Noninvasive coronary angiography with multislice computed tomography [J].
Hoffmann, MHK ;
Shi, HS ;
Schmitz, BL ;
Schmid, FT ;
Lieberknecht, ML ;
Schulze, R ;
Ludwig, B ;
Kroschel, U ;
Jahnke, N ;
Haerer, W ;
Brambs, HJ ;
Aschoff, AJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (20) :2471-2478
[10]   Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease - Patient-versus segment-based analysis [J].
Hoffmann, U ;
Moselewski, F ;
Cury, RC ;
Ferencik, M ;
Jang, IK ;
Diaz, LJ ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
CIRCULATION, 2004, 110 (17) :2638-2643