Reproducible simulation of respiratory motion in porcine lung explants

被引:22
作者
Biederer, J.
Plathow, C.
Schoebinger, M.
Tetzlaff, R.
Puderbach, M.
Boltel, H.
Zaporozhan, J.
Meinzer, H. -P.
Heller, M.
Kauczor, H. -U.
机构
[1] Univ Hosp Schleswig Holstein, Dept Diagnost Radiol, Kiel, Germany
[2] Univ Tubingen, Dept Diagnost Radiol, Tubingen, Germany
[3] German Canc Res Ctr, Dept Radiol, D-6900 Heidelberg, Germany
[4] German Canc Res Ctr, Dept Med & Biol Informat, D-6900 Heidelberg, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2006年 / 178卷 / 11期
关键词
motility; thorax; CT; MR; imaging;
D O I
10.1055/s-2006-927149
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To develop a model for exactly reproducible respiration motion simulations of animal lung explants inside an MR-compatible chest phantom. Materials and Methods: The materials included a piston pump and a flexible silicone reconstruction of a porcine diaphragm and were used in combination with an established MR-compatible chest phantom for porcine heart-lung preparations. The rhythmic inflation and deflation of the diaphragm at the bottom of the artificial thorax with water (1 - 1.5 L) induced lung tissue displacement resembling diaphragmatic breathing. This system was tested on five porcine heart-lung preparations using 1.5T MRI with transverse and coronal 3D-GRE (TR/TE = 3.63/1.58, 256 x 256 matrix, 350 mm FOV, 4 mm slices) and half Fourier T2-FSE (TR/TE = 545/29, 256 x 192, 350 mm, 6 mm) as well as multiple row detector CT (16 x 1 mm collimation, pitch 1.5, FOV 400 mm, 120 mAs) acquired at five fixed inspiration levels. Dynamic CT scans and coronal MRI with dynamic 2D-GRE and 2D-SS-GRE sequences (image frequencies of 10/sec and 3/sec, respectively) were acquired during continuous "breathing" (7/minute). The position of the piston pump was visually correlated with the respiratory motion visible through the transparent wall of the phantom and with dynamic displays of CT and MR images. An elastic body splines analysis of the respiratory motion was performed using CT data. Results: Visual evaluation of MRI and CT showed three-dimensional movement of the lung tissue throughout the respiration cycle. Local tissue displacement inside the lung explants was documented with motion maps calculated from Cr. The maximum displacement at the top of the diaphragm (mean 26.26 [SD 1.9] mm on CT and 27.16 ISD 1.5] mm on MRI, respectively [p = 0.25; Wilcoxon test]) was in the range of tidal breathing in human patients. Conclusion: The chest phantom with a diaphragmatic pump is a promising platform for multi-modality imaging studies of the effects of respiratory lung motion.
引用
收藏
页码:1067 / 1072
页数:6
相关论文
共 24 条
[1]
Artificial thorax for MR imaging studies in porcine heart-lung preparations [J].
Biederer, J ;
Heller, M .
RADIOLOGY, 2003, 226 (01) :250-255
[2]
Lung morphology: Fast MR imaging assessment with a volumetric interpolated breath-hold technique: Initial experience with patients [J].
Biederer, J ;
Both, M ;
Graessner, J ;
Liess, C ;
Jakob, P ;
Reuter, M ;
Heller, M .
RADIOLOGY, 2003, 226 (01) :242-249
[3]
Sensitivity of MRI in detecting alveolar infiltrates: Experimental studies [J].
Biederer, J ;
Busse, I ;
Grimm, J ;
Reuter, M ;
Muhle, C ;
Freitag, S ;
Heller, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08) :1033-1039
[4]
BIEDERER J, 2006, ROFO FORTSCHR RONTG, V178, pS148
[5]
Ex-vivo injection for implanting solid pulmonary nodules into porcine lungs for multi-slice CT [J].
Bolte, H ;
Müller-Hülsbeck, S ;
Riedel, C ;
Jahnke, T ;
Inan, N ;
Heller, M ;
Biederer, J .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (10) :1380-1384
[6]
Fast T1- and T2-weighted pulmonary MR-imaging in patients with bronchial carcinoma [J].
Both, M ;
Schultze, J ;
Reuter, A ;
Bewig, B ;
Hubner, R ;
Bobis, I ;
Noth, R ;
Heller, A ;
Biederer, J .
EUROPEAN JOURNAL OF RADIOLOGY, 2005, 53 (03) :478-488
[7]
A physics-based coordinate transformation for 3-D image matching [J].
Davis, MH ;
Khotanzad, A ;
Flamig, DP ;
Harms, SE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (03) :317-328
[8]
Linac-integrated 4D cone beam CT:: first experimental results [J].
Dietrich, Lars ;
Jetter, Siri ;
Tuecking, Thomas ;
Nill, Simeon ;
Oelfke, Uwe .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11) :2939-2952
[9]
Characterization of regional pulmonary mechanics from serial magnetic resonance imaging data [J].
Gee, J ;
Sundaram, T ;
Hasegawa, I ;
Uematsu, H ;
Hatabu, H .
ACADEMIC RADIOLOGY, 2003, 10 (10) :1147-1152
[10]
Thoracic real-time MRI:: Experience from 2200 examinations in acute and ill-defined thoracic diseases [J].
Kluge, A ;
Gerriets, T ;
Müller, C ;
Ekinci, O ;
Neumann, T ;
Dill, T ;
Bachmann, G .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (11) :1513-1521