Determination of adenine and guanine by capillary zone electrophoresis with end-column amperometric detection at a carbon fiber microdisk array electrode

被引:45
作者
Jin, WR
Wei, HY
Zhao, X
机构
[1] Laboratory of Analytical Science, School of Chemistry, Shandong University
关键词
capillary zone electrophoresis; electrochemical detection; carbon fiber electrode; yeast-RNA; calf thymus-DNA; adenine; guanine;
D O I
10.1002/elan.1140091008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary zone electrophoresis was employed to the analysis of adenine and guanine by using end-column amperometric detector with a carbon fiber microdisk array electrode. Optimum conditions of separation and detection are 0.01 mol/L H3PO4-0.01 mol/L H3BO3-0.01 mol/L HAc-NaOH (pH 9.2) for the buffer solution, 20 kV for the separation voltage, 3.0 kV and 5 s for injection voltage and time, respectively, and 1.00 V (vs.SCE) for the detection potential. The Limit of detection is 8.2 fmol for adenine and 2.9 fmol for guanine (S/N = 2). The method was applied to determination of adenine and guanine in hydrolytic product of yeast-RNA and calf thymus-DNA.
引用
收藏
页码:770 / 774
页数:5
相关论文
共 19 条
[11]   BACKGROUND-NOISE IN CAPILLARY ELECTROPHORETIC AMPEROMETRIC DETECTION [J].
LU, WZ ;
CASSIDY, RM .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :200-204
[12]   HIGH-PERFORMANCE ZONE ELECTROPHORESIS [J].
MIKKERS, FEP ;
EVERAERTS, FM ;
VERHEGGEN, TPEM .
JOURNAL OF CHROMATOGRAPHY, 1979, 169 (FEB) :11-20
[13]   SIMULTANEOUS DETERMINATION OF PURINE AND PYRIMIDINE-BASES USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION - APPLICATION TO DNA ASSAY [J].
NAKAHARA, T ;
OKUZAWA, M ;
MAEDA, H ;
HIRANO, M ;
MATSUMOTO, T ;
UCHIMURA, H .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (10) :1785-1796
[14]   CAPILLARY ELECTROPHORESIS WITH ELECTROCHEMICAL DETECTION EMPLOYING AN ON-COLUMN NAFION JOINT [J].
OSHEA, TJ ;
GREENHAGEN, RD ;
LUNTE, SM ;
LUNTE, CE ;
SMYTH, MR ;
RADZIK, DM ;
WATANABE, N .
JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2) :305-312
[15]   IMPROVED METHOD FOR END-COLUMN AMPEROMETRIC DETECTION FOR CAPILLARY ELECTROPHORESIS [J].
SLOSS, S ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :577-581
[16]   CAPILLARY ZONE ELECTROPHORESIS WITH ELECTROCHEMICAL DETECTION [J].
WALLINGFORD, RA ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1987, 59 (14) :1762-1766
[17]   AMPEROMETRIC DETECTION OF CATECHOLS IN CAPILLARY ZONE ELECTROPHORESIS WITH NORMAL AND MICELLAR SOLUTIONS [J].
WALLINGFORD, RA ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1988, 60 (03) :258-263
[18]   AMPEROMETRIC DETECTION IN CAPILLARY ELECTROPHORESIS WITH NORMAL SIZE ELECTRODES [J].
YE, JN ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1993, 65 (23) :3525-3527
[19]   MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY OF VITAMIN B-6 WITH ELECTROCHEMICAL DETECTION [J].
YIK, YF ;
LEE, HK ;
LI, SFY ;
KHOO, SB .
JOURNAL OF CHROMATOGRAPHY, 1991, 585 (01) :139-144