In-vivo accuracy of geometrically correct three-dimensional reconstruction of human coronary arteries: is it influenced by certain parameters?

被引:16
作者
Chatzizisis, Yiannis S.
Giannoglou, George D.
Matakos, Antonis
Basdekidou, Chrysanthi
Sianos, George
Panagiotou, Alexandros
Dimakis, Christos
Parcharidis, George E.
Louridas, George E.
机构
[1] Aristotle Univ Thessaloniki, Cardiovasc Engn & Atherosclerosis Lab, Cardiol Dept 1, AHEPA Univ Hosp,Med Sch, Thessaloniki 54636, Greece
[2] Aristotle Univ Thessaloniki, Dept Elect & Comp Engn, Sch Engn, GR-54006 Thessaloniki, Greece
关键词
coronary angiography; coronary vessels; interventional ultrasonography; three-dimensional imaging;
D O I
10.1097/00019501-200609000-00008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective The geometrically correct three-dimensional reconstruction of human coronary arteries by integrating intravascular ultrasound (IVUS) and biplane angiography constitutes a promising imaging method for coronaries with broad clinical potential. The determinants of the accuracy of the method, however, have not been investigated before. Methods In total, 17 arterial segments (right coronary artery, n = 7; left anterior descending, n = 4; left circumflex, n=6) derived from nine patients were three-dimensionally reconstructed by applying three-dimensional intravascular ultrasound. The degree of matching between the reconstructed lumen back-projected onto each angiographic plane and the actual lumen in each plane was used as a measure of method's accuracy. The investigated factors that could potentially affect the reliability of the method included the type of the artery (left anterior descending, left circumflex, right coronary artery) and several geometrical and morphological characteristics of the reconstructed arteries. Results The correlation between the back-projected reconstructed lumens and the actual angiographic ones was found to be high (r = 0.78, P < 0.001). Neither the category of the reconstructed arteries nor their particular geometrical and morphological characteristics influenced the accuracy of the reconstruction method significantly. Nonetheless, the method exhibited slightly less accuracy in the reconstruction of right coronary arteries, an observation that could be attributed to the more intense pulsatile motion that this artery experiences during the cardiac cycle compared to the left anterior descending and left circumflex artery. Conclusions The in-vivo accuracy of three-dimensional intravascular ultrasound (3D IVUS) is significantly high regardless of the type of the coronary arteries or their particular geometrical and morphological characteristics. This finding further supports the applicability of the method for either diagnostic or investigational purposes.
引用
收藏
页码:545 / 551
页数:7
相关论文
共 18 条
[1]   Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1964-1971
[2]   American College of Cardiology/Society for Cardiac Angiography and Interventions clinical expert consensus document on Cardiac Catheterization Laboratory standards - A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents [J].
Bashore, TM ;
Bates, ER ;
Berger, PB ;
Clark, DA ;
Cusma, JT ;
Dehmer, GJ ;
Kern, MJ ;
Laskey, WK ;
O'Laughlin, MP ;
Oesterle, S ;
Popma, JJ ;
O'Rourke, RA ;
Abrams, J ;
Bates, ER ;
Brodie, BR ;
Douglas, PS ;
Gregoratos, G ;
Hlatky, MA ;
Hochman, JS ;
Kaul, S ;
Tracy, CM ;
Waters, DD ;
Winters, WL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (08) :2170-2214
[3]  
CHATZIZISIS YS, 2004, THESIS ARISTOTLE U M
[4]   Reproducibility of coronary lumen, plaque, and vessel wall reconstruction and of endothelial shear stress measurements in vivo in humans [J].
Coskun, AU ;
Yeghiazarians, Y ;
Kinlay, S ;
Clark, ME ;
Ilegbusi, OJ ;
Wahle, A ;
Sonka, M ;
Popma, JJ ;
Kuntz, RE ;
Feldman, CL ;
Stone, PH .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 60 (01) :67-78
[5]   Three-dimensional reconstruction of the coronary artery wall by image fusion of intravascular ultrasound and bi-plane angiography [J].
Cothren, RM ;
Shekhar, R ;
Tuzcu, EM ;
Nissen, SE ;
Cornhill, JF ;
Vince, DG .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2000, 16 (02) :69-85
[6]   Dynamics of human coronary arterial motion and its potential role in coronary atherogenesis [J].
Ding, ZH ;
Friedman, MH .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (05) :488-492
[7]   In-vivo validation of spatially correct three-dimensional reconstruction of human coronary arteries by integrating intravascular ultrasound and biplane angiography [J].
Giannoglou, George D. ;
Chatzizisis, Yiannis S. ;
Sianos, George ;
Tsikaderis, Dimitrios ;
Matakos, Antonis ;
Koutkias, Vassilios ;
Diamantopoulos, Panagiotis ;
Maglaveras, Nicos ;
Parcharidis, George E. ;
Louridas, George E. .
CORONARY ARTERY DISEASE, 2006, 17 (06) :533-543
[8]   Automated three-dimensional assessment of coronary artery anatomy with intravascular ultrasound scanning [J].
Klingensmith, JD ;
Schoenhagen, P ;
Tajaddini, A ;
Halliburton, SS ;
Tuzcu, EM ;
Nissen, SE ;
Vince, DG .
AMERICAN HEART JOURNAL, 2003, 145 (05) :795-805
[9]   Non-invasive coronary angiography with high resolution multidetector-row computed tomography - Results in 102 patients [J].
Kopp, AF ;
Schroeder, S ;
Kuettner, A ;
Baumbach, A ;
Georg, C ;
Kuzo, R ;
Heuschmid, M ;
Ohnesorge, B ;
Karsch, KR ;
Claussen, CD .
EUROPEAN HEART JOURNAL, 2002, 23 (21) :1714-1725
[10]   Three-dimensional automatic quantitative analysis of intravascular ultrasound images [J].
Kovalski, G ;
Beyar, R ;
Shofti, R ;
Azhari, H .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (04) :527-537