The diagnostic performance of radiographic criteria to detect aseptic acetabular component loosening after revision total hip arthroplasty

被引:19
作者
Abrahams, J. M. [1 ,2 ,3 ]
Kim, Y. S. [1 ,4 ]
Callary, S. A. [1 ,2 ,3 ]
De Ieso, C. [1 ,5 ]
Costi, K. [1 ,2 ]
Howie, D. W. [1 ,2 ,3 ]
Solomon, L. B. [1 ,2 ,3 ]
机构
[1] Royal Adelaide Hosp, Adelaide, SA, Australia
[2] Royal Adelaide Hosp, Dept Orthopaed & Trauma, Level 4 Bice Bldg,North Terrace, Adelaide, SA, Australia
[3] Univ Adelaide, Discipline Orthopaed & Trauma, Adelaide, SA, Australia
[4] Dongguk Univ Gyeongju Hosp, Gyeongju, Gyeongsangbuk D, South Korea
[5] Villa Stuart Sport Clin, Rome, Italy
关键词
FOLLOW-UP; TRABECULAR METAL; MIGRATION; MINIMUM; CUPS; REPLACEMENT; MANAGEMENT; FIXATION; AUGMENTS; DEFECTS;
D O I
10.1302/0301-620X.99B4.BJJ-2016-0804.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Aims This study aimed to determine the diagnostic performance of radiographic criteria to detect aseptic acetabular loosening after revision total hip arthroplasty (THA). Secondary aims were to determine the predictive values of different thresholds of migration and to determine the predictive values of radiolucency criteria. Patients and Methods Acetabular component migration to re-revision was measured retrospectively using Ein-Bild-Rontgen-Analyse (EBRA-Cup) and manual measurements (Sutherland method) in two groups: Group A, 52 components (48 patients) found not loose at re-revision and Group B, 42 components (36 patients) found loose at re-revision between 1980 and 2015. The presence and extent of radiolucent lines was also assessed. Results Using EBRA, both proximal translation and sagittal rotation were excellent diagnostic tests for detecting aseptic loosening. The area under the receiver operating characteristic (ROC) curves was 0.94 and 0.93, respectively. The thresholds of 2.5 mm proximal translation or 2 degrees sagittal rotation (EBRA) in combination with radiolucency criteria had a sensitivity of 93% and specificity of 88% to detect aseptic loosening. The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of radiolucency criteria were 41%, 100%, 100% and 68% respectively. Manual measurements of both proximal translation and sagittal rotation were very good diagnostic tests. The area under the ROC curve was 0.86 and 0.92 respectively. However, manual measurements had a decreased specificity compared with EBRA. Radiolucency criteria had a poor sensitivity and NPV of 41% and 68% respectively. Conclusion This study shows that EBRA and manual migration measurements can be used as accurate diagnostic tools to detect aseptic loosening of cementless acetabular components used at revision THA. Radiolucency criteria should not be used in isolation to exclude loosening of cementless acetabular components used at revision THA given their poor sensitivity and NPV.
引用
收藏
页码:458 / 464
页数:7
相关论文
共 28 条
[1]
The precision of radiostereometric measurements.: Manual vs. digital measurements [J].
Börlin, N ;
Thien, T ;
Kärrholm, J .
JOURNAL OF BIOMECHANICS, 2002, 35 (01) :69-79
[2]
CARLSSON AS, 1984, CLIN ORTHOP RELAT R, P145
[3]
Long-Term Clinical and Radiographic Outcomes of Porous Tantalum Monoblock Acetabular Component in Primary Hip Arthroplasty: A Minimum of 15-Year Follow-Up [J].
De Martino, Ivan ;
De Santis, Vincenzo ;
Sculco, Peter K. ;
D'Apolito, Rocco ;
Poultsides, Lazaros A. ;
Gasparini, Giorgio .
JOURNAL OF ARTHROPLASTY, 2016, 31 (09) :S110-S114
[4]
Tantalum Augments for Paprosky IIIA Defects Remain Stable at Midterm Followup [J].
Del Gaizo, Daniel J. ;
Kancherla, Vamsi ;
Sporer, Scott M. ;
Paprosky, Wayne G. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (02) :395-401
[5]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[6]
Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty [J].
Della Valle, AG ;
Zoppi, A ;
Peterson, MGE ;
Salvati, EA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (09) :1998-2004
[7]
Ellenrieder M, 2016, ACTA ORTHOP BELG, V82, P60
[8]
POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55
[9]
High migration rate of two types of threaded acetabular cups [J].
Fink, B ;
Protzen, M ;
Hansen-Algenstaedt, N ;
Berger, J ;
Rüther, W .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2004, 124 (01) :17-25
[10]
Management of severe bone loss in acetabular revision using a trabecular metal shell [J].
Flecher, Xavier ;
Sporer, Scott ;
Paprosky, Wayne .
JOURNAL OF ARTHROPLASTY, 2008, 23 (07) :949-955