Renal magnetic resonance angiography at 3.0 Tesla using a 32-element phased-array coil system and parallel imaging in 2 directions

被引:24
作者
Fenchel, Michael
Nael, Kambiz
Deshpande, Vibhas S.
Finn, J. Paul
Kramer, Ulrich
Miller, Stephan
Ruehm, Stefan
Laub, Gerhard
机构
[1] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90024 USA
[3] Siemens Med Solut, Malvern, PA USA
关键词
magnetic resonance; MR angiography; MRA; parallel imaging; GRAPPA; 3; Tesla;
D O I
10.1097/01.rli.0000233319.04760.a4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of the present study was to assess the feasibility of renal magnetic resonance angiography at 3.0 T using a phased-array coil system with 32-coil elements. Specifically, high parallel imaging factors were used for an increased spatial resolution and anatomic coverage of the whole abdomen. Materials and Methods: Signal-to-noise values and the g-factor distribution of the 32 element coil were examined in phantom studies for the magnetic resonance angiography (MRA) sequence. Eleven volunteers (6 men, median age of 30.0 years) were examined on a 3.0-T MR scanner (Magnetom Trio, Siemens Medical Solutions, Malvern, PA) using a 32-element phased-array coil (prototype from In vivo Corp.). Contrast-enhanced 3D-MRA (TR 2.95 milliseconds, TE 1.12 milliseconds, flip angle 25-30', bandwidth 650 Hz/pixel) was acquired with integrated generalized autocalibrating partially parallel acquisition (GRAPPA), in both phase- and slice-encoding direction. Images were assessed by 2 independent observers with regard to image quality, noise and presence of artifacts. Results: Signal-to-noise levels of 22.2 +/- 22.0 and 57.9 +/- 49.0 were measured with (GRAPPAx6) and without parallel-imaging, respectively. The mean g-factor of the 32-element coil for GRAPPA with an acceleration of 3 and 2 in the phase-encoding and slice-encoding direction, respectively, was 1.61. High image quality was found in 9 of I I volunteers (2.6 +/- 0.8) with good overall interobserver agreement (k = 0.87). Relatively low image quality with higher noise levels were encountered in 2 volunteers. Conclusion: MRA at 3.0 T using a 32-element phased-array coil is feasible in healthy volunteers. High diagnostic image quality and extended anatomic coverage could be achieved with application of high parallel imaging factors.
引用
收藏
页码:697 / 703
页数:7
相关论文
共 23 条
[1]   Effect of field strengths on magnetic resonance angiography - Comparison of an ultrasmall superparamagnetic iron oxide blood-pool contrast agent and gadopentetate dimeglumine in rabbits at 1.5 and 3.0 tesla [J].
Allkemper, T ;
Heindel, W ;
Kooijman, H ;
Ebert, W ;
Tombach, B .
INVESTIGATIVE RADIOLOGY, 2006, 41 (02) :97-104
[2]  
Bernstein MA, 2001, MAGNET RESON MED, V46, P955, DOI 10.1002/mrm.1282
[3]   Renal arterial stenosis: Prospective comparison of color Doppler US and breath-hold, three-dimensional, dynamic, gadolinium-enhanced MR angiography [J].
De Cobelli, F ;
Venturini, M ;
Vanzulli, A ;
Sironi, S ;
Salvioni, M ;
Angeli, E ;
Scifo, P ;
Garancini, MP ;
Quartagno, R ;
Bianchi, G ;
Del Maschio, A .
RADIOLOGY, 2000, 214 (02) :373-380
[4]   High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: A prospective comparison with digital subtraction angiography [J].
Fain, SB ;
King, BF ;
Breen, JF ;
Kruger, DG ;
Riederer, SJ .
RADIOLOGY, 2001, 218 (02) :481-490
[5]   Functional MRI of the kidney [J].
Grenier, N ;
Basseau, F ;
Ries, M ;
Tyndal, B ;
Jones, R ;
Moonen, C .
ABDOMINAL IMAGING, 2002, 28 (02) :164-175
[6]   High-resolution magnetic resonance angiography of the renal arteries using parallel imaging acquisition techniques at 3.0 T - Initial experience [J].
Kramer, U ;
Nael, K ;
Laub, G ;
Nyborg, GK ;
Fenchel, M ;
Miller, S ;
Claussen, CD ;
Finn, JP .
INVESTIGATIVE RADIOLOGY, 2006, 41 (02) :125-132
[7]   Single-dose breath-hold gadolinium-enhanced three-dimensional MR angiography of the renal arteries [J].
Lee, VS ;
Rofsky, NM ;
Krinsky, GA ;
Stemerman, DH ;
Weinreb, JC .
RADIOLOGY, 1999, 211 (01) :69-78
[8]   Self-calibrating parallel imaging with automatic coil sensitivity extraction [J].
McKenzie, CA ;
Yeh, EN ;
Ohliger, MA ;
Price, MD ;
Sodickson, DK .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) :529-538
[9]   The feasibility of spatial high-resolution magnetic resonance angiography (MRA) of the renal arteries at 3.0 T [J].
Michaely, HJ ;
Nael, K ;
Schoenberg, S ;
Finn, JP ;
Laub, G ;
Reiser, MF ;
Ruehm, SG .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (06) :800-804
[10]   Renal disease: Value of functional magnetic resonance imaging with flow and perfusion measurements [J].
Michaely, HJ ;
Schoenberg, SO ;
Ittrich, C ;
Dikow, R ;
Bock, M ;
Guenther, M .
INVESTIGATIVE RADIOLOGY, 2004, 39 (11) :698-705