Helical tomotherapy dynamic quality assurance

被引:31
作者
Balog, John [1 ]
Holmes, Tim
Vaden, Richard
机构
[1] Mohawk Valley Med Phys, Rome, NY 13440 USA
[2] St Agnes HealthCare, Baltimore, MD 21229 USA
[3] EC Rost Oncol LLC, Tallahassee, FL USA
关键词
D O I
10.1118/1.2351952
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A multifaceted tomotherapy quality assurance procedure has been developed. This procedure tests most of the features inherent in the tomotherapy Hi-Art device. This includes the megavoltage imaging quality, spatial and temporal accuracy of the dynamic delivery properties, as well as more traditional beam output characteristics. This is accomplished with a specialized multichannel electrometer that measures collected charge every 100 ms and a Virtual Water cylindrical phantom that holds many ion chambers and differing density insert plugs. Both devices are offered with the Hi-Art product. These tests are presented as well as their sensitivity to beam and delivery variations. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:3939 / 3950
页数:12
相关论文
共 14 条
[1]   Clinical helical tomotherapy commissioning dosimetry [J].
Balog, J ;
Olivera, G ;
Kapatoes, J .
MEDICAL PHYSICS, 2003, 30 (12) :3097-3106
[2]   Benchmarking beam alignment for a clinical helical tomotherapy device [J].
Balog, J ;
Mackie, TR ;
Pearson, D ;
Hui, S ;
Paliwal, B ;
Jeraj, R .
MEDICAL PHYSICS, 2003, 30 (06) :1118-1127
[3]   Characterization of the output for helical delivery of intensity modulated slit beams [J].
Balog, JP ;
Mackie, TR ;
Reckwerdt, P ;
Glass, M ;
Angelos, L .
MEDICAL PHYSICS, 1999, 26 (01) :55-64
[4]   Quality assurance of a helical tomotherapy machine [J].
Fenwick, JD ;
Tomé, WA ;
Jaradat, HA ;
Hui, SK ;
James, JA ;
Balog, JP ;
DeSouza, CN ;
Lucas, DB ;
Olivera, GH ;
Mackie, TR ;
Paliwal, BR .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (13) :2933-2953
[5]   Tomotherapy daily quality assurance phantom [J].
Jaradat, H ;
Paliwal, B ;
Mehta, M .
MEDICAL PHYSICS, 2005, 32 (06) :1989-1989
[6]   Radiation characteristics of helical tomotherapy [J].
Jeraj, R ;
Mackie, TR ;
Balog, J ;
Olivera, G ;
Pearson, D ;
Kapatoes, J ;
Ruchala, K ;
Reckwerdt, P .
MEDICAL PHYSICS, 2004, 31 (02) :396-404
[7]   COMPREHENSIVE QA FOR RADIATION ONCOLOGY - REPORT OF AAPM RADIATION-THERAPY COMMITTEE TASK-GROUP-40 [J].
KUTCHER, GJ ;
COIA, L ;
GILLIN, M ;
HANSON, WF ;
LEIBEL, S ;
MORTON, RJ ;
PALTA, JR ;
PURDY, JA ;
REINSTEIN, LE ;
SVENSSON, GK ;
WELLER, M ;
WINGFIELD, L .
MEDICAL PHYSICS, 1994, 21 (04) :581-618
[8]   Tomotherapy [J].
Mackie, TR ;
Balog, J ;
Ruchala, K ;
Shepard, D ;
Aldridge, S ;
Fitchard, E ;
Reckwerdt, P ;
Olivera, G ;
McNutt, T ;
Mehta, M .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :108-117
[9]   TOMOTHERAPY - A NEW CONCEPT FOR THE DELIVERY OF DYNAMIC CONFORMAL RADIOTHERAPY [J].
MACKIE, TR ;
HOLMES, T ;
SWERDLOFF, S ;
RECKWERDT, P ;
DEASY, JO ;
YANG, J ;
PALIWAL, B ;
KINSELLA, T .
MEDICAL PHYSICS, 1993, 20 (06) :1709-1719
[10]   Technical Note: Output and energy fluctuations of the tomotherapy Hi-Art helical tomotherapy system [J].
Mahan, SL ;
Chase, DJ ;
Ramsey, CR .
MEDICAL PHYSICS, 2004, 31 (07) :2119-2120