Absolute quantification of cerebral blood flow with magnetic resonance, reproducibility of the method, and comparison with H215O positron emission tomography

被引:81
作者
Carroll, TJ
Teneggi, V
Jobin, M
Squassante, L
Treyer, V
Hany, TF
Burger, C
Wang, L
Bye, T
von Schulthess, GK
Buck, A
机构
[1] Univ Zurich Hosp, Div Nucl Med, PET Ctr, CH-8091 Zurich, Switzerland
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[3] Glaxo SmithKline, Med Res Ctr, Verona, Italy
[4] Addenbrookes Hosp, GlaxoSmithKline Res & Dev, Cambridge, England
关键词
magnetic resonance imaging; cerebral perfusion; positron emission tomography;
D O I
10.1097/00004647-200209000-00013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
While (H2O)-O-15 positron emission tomography (PET) is still the gold standard in the quantitative assessment of cerebral perfusion (rCBF), its technical challenge, limited availability, and radiation exposure are disadvantages of the method. Recent work demonstrated the feasibility of magnetic resonance (MR) for quantitative cerebral perfusion imaging. There remain open questions, however, especially regarding reproducibility. The main purpose of this study was to assess the accuracy and reproducibility of MR-derived flow values to those derived from (H2O)-O-15 PET. Positron emission tomography and MR perfusion imaging was performed in 20 healthy male volunteers, who were chronic smokers, on day I and day 3 of a 4-day hospitalization. Subjects were randomly assigned to one of two groups, each with 10 subjects. One group was allowed to smoke as usual during the hospitalization, while the other group stopped smoking from day 2. Positron emission tomography and MR images were coregistered and rCBF was determined in two regions of interest, defined over gray matter (gm) and white matter (wm), yielding rCBF(PETgm), rCBF(MRgm), rCBF(PETwm), and rCBF(MRwm). Bland-Altman analysis was used to investigate reproducibility by assessing the difference rCBF(day3) - rCBF(day1) in eight continual-smoker volunteers. The analysis showed a good reproducibility for PET, but not for MR. Mean+/-SD of the difference rCBF(day3) - rCBF(day1) in gray matter was 6.35+/-21.06 and 0.49+/-5.27 mL . min(-1) . 100 g(-1) for MR and PET, respectively; the corresponding values in white matter were 2.60+/-15.64 and -1.14+/-4.16 mL . min(-1) . 100 g(-1). The Bland-Altman analysis was also used to assess MRI and PET agreement comparing rCBF measured on day 1. The analysis demonstrated a reasonably good agreement of MR and PET in white matter (rCBF(PETwm) - rCBF(MRwm); -0.09+/-7.23 mL . min(-1) . 100 g(-1)), while in gray matter a reasonable agreement was only achieved after removing vascular artifacts in the MR perfusion maps (rCBF(PETgm) - rCBF(MRgm); -11.73+/-14.52 mL . min(-1) . 100 g(-1)). In line with prior work, these results demonstrate that reproducibility was overall considerably better for PET than for MR. Until reproducibility is improved and vascular artifacts are efficiently removed, MR is not suitable for reliable quantitative perfusion measurements.
引用
收藏
页码:1149 / 1156
页数:8
相关论文
共 22 条
  • [1] STRATEGY FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW USING SHORT-LIVED TRACERS AND EMISSION TOMOGRAPHY
    ALPERT, NM
    ERIKSSON, L
    CHANG, JY
    BERGSTROM, M
    LITTON, JE
    CORREIA, JA
    BOHM, C
    ACKERMAN, RH
    TAVERAS, JM
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (01) : 28 - 34
  • [2] MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS
    BOXERMAN, JL
    HAMBERG, LM
    ROSEN, BR
    WEISSKOFF, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 555 - 566
  • [3] CARROLL TJ, 2001, INT SOC MAGN RES MED
  • [4] CARROLL TJ, 2000, INT SOC MAGN RES MED
  • [5] QUALITATIVE MAPPING OF CEREBRAL BLOOD-FLOW AND FUNCTIONAL LOCALIZATION WITH ECHO-PLANAR MR-IMAGING AND SIGNAL TARGETING WITH ALTERNATING RADIO-FREQUENCY
    EDELMAN, RR
    SIEWERT, B
    DARBY, DG
    THANGARAJ, V
    NOBRE, AC
    MESULAM, MM
    WARACH, S
    [J]. RADIOLOGY, 1994, 192 (02) : 513 - 520
  • [6] Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET: I. Theory, error analysis, and stereologic comparison
    Iida, H
    Law, I
    Pakkenberg, B
    Krarup-Hansen, A
    Eberl, S
    Holm, S
    Hansen, AK
    Gundersen, HJG
    Thomsen, C
    Svarer, C
    Ring, P
    Friberg, L
    Paulson, OB
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2000, 20 (08) : 1237 - 1251
  • [7] Quantitative measurements of cerebral blood flow in patients with unilateral carotid artery occlusion: A PET and MR study
    Lin, W
    Celik, A
    Derdeyn, C
    An, H
    Lee, Y
    Videen, T
    Ostergaard, L
    Powers, WJ
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (06) : 659 - 667
  • [8] REPRODUCIBILITY OF RESTING CEREBRAL BLOOD-FLOW MEASUREMENTS WITH H215O POSITRON EMISSION TOMOGRAPHY IN HUMANS
    MATTHEW, E
    ANDREASON, P
    CARSON, RE
    HERSCOVITCH, P
    PETTIGREW, K
    COHEN, R
    KING, C
    JOHANSON, CE
    PAUL, SM
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1993, 13 (05) : 748 - 754
  • [9] MEYER E, 1989, J NUCL MED, V30, P1069
  • [10] A JAVA']JAVA environment for medical image data analysis: initial application for brain PET quantitation
    Mikolajczyk, K
    Szabatin, M
    Rudnicki, P
    Grodzki, M
    Burger, C
    [J]. MEDICAL INFORMATICS, 1998, 23 (03): : 207 - 214