MR-guided angioplasty of renal artery stenosis in a pig model: A feasibility study

被引:55
作者
Omary, RA
Frayne, R
Unal, O
Warner, T
Korosec, FR
Mistretta, CA
Strother, CM
Grist, TM
机构
[1] Univ Wisconsin, Dept Radiol, Sch Med, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Phys Med, Sch Med, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Pathol, Sch Med, Madison, WI 53706 USA
关键词
magnetic resonance (MR); vascular studies magnetic resonance (MR); guidance; renal arteries; stenosis or obstruction;
D O I
10.1016/S1051-0443(07)61433-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To test the hypothesis that magnetic resonance (MR) imaging can guide the percutaneous treatment of renal artery stenosis in a pig model. MATERIALS AND METHODS: Ameroid constrictors were surgically placed around six renal arteries in four pigs, After 30-36 days, all stenoses were documented by conventional x-ray aortograms. MR-guided renal angioplasty was attempted for three stenoses. For these pigs, MR angiography was performed with use of contrast-enhanced three-dimensional (3D) techniques, The authors visualized catheters by filling them with dilute 4% gadolinium and imaging with two-dimensional (2D) and 3D MR fast spoiled gradient recalled echo techniques. Under MR guidance, the authors advanced a selective catheter into the affected renal artery and crossed the stenosis with a nitinol guide wire. Angioplasty was performed with a balloon catheter filled with dilute gadolinium. Stenosis and luminal diameter measurements were compared before and after angioplasty. RESULTS: After ameroid constrictor placement, four significant stenoses, one mild stenosis, and one occlusion developed. Under MR guidance, the authors achieved technical success in performing three of three (100%) attempted dilations. After MR-guided angioplasty, the mean reduction in stenosis was 35% and the mean increase in luminal diameter was 1.6 mm. CONCLUSION: Use of MR guidance for the angioplasty of renal artery stenosis in pigs is feasible.
引用
收藏
页码:373 / 381
页数:9
相关论文
共 34 条
[1]   Visualization of MR-compatible catheters by electrically induced local field inhomogeneities:: Evaluation in vivo [J].
Adam, G ;
Glowinski, A ;
Neuerburg, J ;
Bücker, A ;
van Vaals, JJ ;
Günther, RW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :209-213
[2]   MR-guided endovascular interventions: Susceptibility-based catheter and near-real-time imaging technique [J].
Bakker, CJ ;
Hoogeveen, RM ;
Hurtak, WF ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WPTM .
RADIOLOGY, 1997, 202 (01) :273-276
[3]   Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions [J].
Bakker, CJ ;
Hoogeveen, RM ;
Weber, J ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WP .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :816-820
[4]   Treatment of ostial renal-artery stenoses with vascular endoprostheses after unsuccessful balloon angioplasty [J].
Blum, U ;
Krumme, B ;
Flugel, P ;
Gabelmann, A ;
Lehnert, T ;
BuitragoTellez, C ;
Schollmeyer, P ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (07) :459-465
[5]  
BROOKS DP, 1992, LAB ANIM SCI, V42, P67
[6]   CO2 digital subtraction angiography: Potential complications and their prevention [J].
Caridi, JG ;
Hawkins, IF .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (03) :383-391
[7]   REAL-TIME POSITION MONITORING OF INVASIVE DEVICES USING MAGNETIC-RESONANCE [J].
DUMOULIN, CL ;
SOUZA, SP ;
DARROW, RD .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) :411-415
[8]  
FRAYNE R, 1999, P ISMRM, P1885
[9]   Catheter visualization using locally induced, actively controlled field inhomogeneities [J].
Glowinski, A ;
Adam, G ;
Bucker, A ;
Neuerburg, J ;
vanVaals, JJ ;
Gunther, RW .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :253-258
[10]  
HAWKINS IF, 1982, AM J ROENTGENOL, V139, P19, DOI 10.2214/ajr.139.1.19