Monitoring of respiratory variations of aortic blood flow velocity using esophageal Doppler

被引:50
作者
Slama, M [1 ]
Masson, H
Teboul, JL
Arnould, ML
Nait-Kaoudjt, R
Colas, B
Peltier, M
Tribouilloy, C
Susic, D
Frohlich, E
Andréjak, M
机构
[1] Univ Picardie Jules Verne, Lab Physiopathol & Pharmacol Cardiovasc, Fac Med, F-80054 Amiens 1, France
[2] CHU Bicetre, Serv Reanimat Med, F-94275 Le Kremlin Bicetre, France
[3] Ochsner Med Inst, Div Res, New Orleans, LA 70121 USA
关键词
esophageal Doppler; hypovolemia; stroke volume variation; cardiac preload;
D O I
10.1007/s00134-004-2190-z
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. The purpose of this study was to determine whether monitoring of respiratory changes in aortic blood flow velocity, recorded by esophageal Doppler, could be used to detect changes in volume depletion. Design. Animal study. Animals and interventions. After general anesthesia and tracheotomy, ten New Zealand female rabbits, weighing 4-4.5 kg were studied under mechanical ventilation at a fixed tidal volume; during this time 5-ml blood samples were withdrawn (in increments up to a total of 30 ml) and then retransfused. Measurements and results. At each step, systolic (SBP), diastolic (DBP), pulse (PP) pressures and maximum descending aortic blood flow (V) were recorded. Respiratory changes of V (DeltaV), SBP (DeltaSBP) and PP (DeltaPP) were calculated as the difference of maximal and minimal values divided by their respective means and expressed as a percentage. The amount of blood withdrawn correlated negatively with SBP, DBP, PP and V and positively with DeltaSBP, DeltaPP and DeltaV. Among these parameters, DeltaV correlated best with the amount of blood withdrawn (r=0.89, p<0.001) and it was the most accurate index of volume depletion. Conclusion. Monitoring of the respiratory variation in V, calculated by esophageal Doppler technique, seems to be a highly accurate index of blood volume depletion and restitution.
引用
收藏
页码:1182 / 1187
页数:6
相关论文
共 20 条
[1]  
Berkenstadt H, 2001, ANESTH ANALG, V92, P984
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Noninvasive cardiac output monitoring by aortic blood flow determination:: Evaluation of the Sometec Dynemo-3000 system [J].
Cariou, A ;
Monchi, M ;
Joly, LM ;
Bellenfant, F ;
Claessens, YE ;
Thébert, D ;
Brunet, F ;
Dhainaut, JF .
CRITICAL CARE MEDICINE, 1998, 26 (12) :2066-2072
[4]  
CORIAT P, 1994, ANESTH ANALG, V78, P46
[5]   Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock [J].
Feissel, M ;
Michard, F ;
Mangin, I ;
Ruyer, O ;
Faller, JP ;
Teboul, JL .
CHEST, 2001, 119 (03) :867-873
[6]   CYCLIC CHANGES IN ARTERIAL PULSE DURING RESPIRATORY SUPPORT [J].
JARDIN, F ;
FARCOT, JC ;
GUERET, P ;
PROST, JF ;
OZIER, Y ;
BOURDARIAS, JP .
CIRCULATION, 1983, 68 (02) :266-274
[7]   NONINVASIVE AORTIC BLOOD-FLOW MEASUREMENT USING AN INTRAESOPHAGEAL PROBE [J].
LAVANDIER, B ;
CATHIGNOL, D ;
MUCHADA, R ;
XUAN, BB ;
MOTIN, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (03) :451-460
[8]   Predicting fluid responsiveness in ICU patients - A critical analysis of the evidence [J].
Michard, F ;
Teboul, JL .
CHEST, 2002, 121 (06) :2000-2008
[9]   Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure [J].
Michard, F ;
Boussat, S ;
Chemla, D ;
Anguel, N ;
Mercat, A ;
Lecarpentier, Y ;
Richard, C ;
Pinsky, MR ;
Teboul, JL .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (01) :134-138
[10]   Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients - Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension [J].
Perel, A .
ANESTHESIOLOGY, 1998, 89 (06) :1309-1310