Ventilation imaging of the lung: Comparison of hyperpolarized helium-3 MR imaging with Xe-133 scintigraphy

被引:27
作者
Altes, TA
Rehm, PK
Harrell, F
Salerno, M
Daniel, TM
de Lange, EE
机构
[1] Univ Virginia, Dept Radiol, Charlottesville, VA 22908 USA
[2] Univ Virginia, Dept Radiol Res, Charlottesville, VA 22908 USA
[3] Univ Virginia, Dept Hlth Evaluat Sci, Charlottesville, VA 22908 USA
[4] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22908 USA
[5] Univ Virginia, Dept Surg, Charlottesville, VA 22908 USA
[6] Cincinnati Childrens Hosp, Ctr Med, Dept Radiol, Cincinnati, OH USA
关键词
chest MRI; hyperpolarized gas MRI; lung ventilation imaging; Xe-133; radionuclide imaging;
D O I
10.1016/j.acra.2004.04.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To compare hyperpolarized helium-3 (HHe) magnetic resonance imaging (MRI) of the lung with standard Xe-133 lung ventilation scintigraphy. Materials and Methods. We performed a retrospective review of 15 subjects who underwent HHe MRI and Xe-133 lung ventilation imaging. Coronal MRI sections were acquired after a single inhalation of HHe gas, and standard posterior planar lung ventilation scintigraphy was performed during continuous breathing of Xe-133 gas. The first breath scintigram of each patient was compared with a composite MR image composed of the sum of the individual MR images and with the individual helium-3 MR images. Ventilation defects on the two imaging modalities were compared for size, conspicuity, and concordance in presence and location. Assessment was done separately for each of four lung quadrants. Results. Comparing the composite HHe MR images with Xe-133 scintigraphy, ventilation defect size, conspicuity and concordance were the same in 67% (40/60), 63% (38/60), and 62% (37/60) quadrants, respectively. Comparing the individual HHe MR image sections with the Xe-133 ventilation scan, there was concordance between the ventilation defects in 27% (16/60) of quadrants. More defects were identified on the individual HHe MR images in 62% (37/60) of quadrants. Conclusion. There was good agreement between composite HHe MR image and first breath Xe-133 scintigraphic images, supporting the widely held assumption that HHe MRI likely depicts first breath lung ventilation.
引用
收藏
页码:729 / 734
页数:6
相关论文
共 12 条
[1]   Hyperpolarized 3He MR lung ventilation imaging in asthmatics:: Preliminary findings [J].
Altes, TA ;
Powers, PL ;
Knight-Scott, J ;
Rakes, G ;
Platts-Mills, TAE ;
de Lange, EE ;
Alford, BA ;
Mugler, JP ;
Brookeman, JR .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (03) :378-384
[2]   In vivo He-3 MR images of guinea pig lungs [J].
Black, RD ;
Middleton, HL ;
Cates, GD ;
Cofer, GP ;
Driehuys, B ;
Happer, W ;
Hedlund, LW ;
Johnson, GA ;
Shattuck, MD ;
Swartz, JC .
RADIOLOGY, 1996, 199 (03) :867-870
[3]   Lung air spaces:: MR imaging evaluation with hyperpolarized 3He gas [J].
de Lange, EE ;
Mugler, JP ;
Brookeman, JR ;
Knight-Scott, J ;
Truwit, JD ;
Teates, CD ;
Daniel, TM ;
Bogorad, PL ;
Cates, GD .
RADIOLOGY, 1999, 210 (03) :851-857
[4]   Cystic fibrosis:: Combined hyperpolarized 3He-enhanced and conventional proton MR imaging in the lung -: Preliminary observations [J].
Donnelly, LF ;
MacFall, JR ;
McAdams, HP ;
Majure, JM ;
Smith, J ;
Frush, DP ;
Bogonad, P ;
Charles, HC ;
Ravin, CE .
RADIOLOGY, 1999, 212 (03) :885-889
[5]   Statistical issues in analysis of diagnostic imaging experiments with multiple observations per patient [J].
Gönen, M ;
Panageas, KS ;
Larson, SM .
RADIOLOGY, 2001, 221 (03) :763-767
[6]   Normal and abnormal pulmonary ventilation: Visualization at hyperpolarized He-3 MR imaging [J].
Kauczor, HU ;
Hofmann, D ;
Kreitner, KF ;
Nilgens, H ;
Surkau, R ;
Heil, W ;
Potthast, A ;
Knopp, MV ;
Otten, EW ;
Thelen, M .
RADIOLOGY, 1996, 201 (02) :564-568
[7]   Imaging of the lungs using 3He MRI: Preliminary clinical experience in 18 patients with and without lung disease [J].
Kauczor, HU ;
Ebert, M ;
Kreitner, KF ;
Nilgens, H ;
Surkau, R ;
Heil, W ;
Hofmann, D ;
Otten, EW ;
Thelen, M .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :538-543
[8]   Human lung air spaces: Potential for MR imaging with hyperpolarized He-3 [J].
MacFall, JR ;
Charles, HC ;
Black, RD ;
Middleton, H ;
Swartz, JC ;
Saam, B ;
Driehuys, B ;
Erickson, C ;
Happer, W ;
Cates, GD ;
Johnson, GA ;
Ravin, CE .
RADIOLOGY, 1996, 200 (02) :553-558
[9]   Hyperpolarized 3He-enhanced MR imaging of lung transplant recipients:: Preliminary results [J].
McAdams, HP ;
Palmer, SM ;
Donnelly, LF ;
Charles, HC ;
Tapson, VF ;
MacFall, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (04) :955-959
[10]   NOTE ON THE SAMPLING ERROR OF THE DIFFERENCE BETWEEN CORRELATED PROPORTIONS OR PERCENTAGES [J].
McNemar, Quinn .
PSYCHOMETRIKA, 1947, 12 (02) :153-157