Multiple-point electrochemical detection for a dual-channel hybrid PDMS-glass microchip electrophoresis device

被引:8
作者
Castano-Alvarez, Mario [1 ]
Fernandez-la-Vilia, Ana [1 ]
Pozo-Ayuso, Diego F. [2 ]
Teresa Fernandez-Abedul, Maria [1 ]
Costa-Garcia, Agustin [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Oviedo 33006, Asturias, Spain
[2] Univ Oviedo, Dept Fis, E-33007 Oviedo, Asturias, Spain
关键词
Dual-channel; Electrochemical detection; Gold end-channel detector; Microchip electrophoresis; PDMS; CAPILLARY-ELECTROPHORESIS; MICROFLUIDIC DEVICES; MUTATION DETECTION; DNA ANALYSIS; POLY(DIMETHYLSILOXANE); SEPARATIONS; PERFORMANCE; CHIP; INTEGRATION; FABRICATION;
D O I
10.1002/elps.200900291
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new PDMS-based dual-channel MCE with multiple-point amperometric detection has been evaluated. Electrophoresis has been optimised in a single-channel device. Pretreatment with 0.1 M NaOH is very important for increasing and stabilising the EOF. The precision is adequate for a day's work in terms of both peak current and migration time. The RSD of the peak current for five successive signals was 1.9, 2.4 and 3.1% for dopamine, p-aminophenol and hydroquinone. RSD for the migration time was always less than 1.3%, which demonstrates the stability of the EOF and the possibility of running multiple experiments in the same microchip. The adequate inter-microchip precision as well as the rapid and simple manufacturing procedure indicates the disposable nature of the PDMS microchips. A dual-channel device with very simple multiple-point amperometric detection is proposed here. Elasticity of the PDMS allows removing the polymer slightly and aligning gold wires working electrodes. Injection can be performed from each of the sample reservoirs or from both simultaneously. The distance between the separation channels is critical for obtaining adequate signals as well as the introduction of a high-voltage electrode in the buffer reservoir. Simultaneous measurement of the same analytes in both channels is possible by applying the same potential. Moreover, since no cross-separation is produced, different analytes or samples can be simultaneously measured.
引用
收藏
页码:3372 / 3380
页数:9
相关论文
共 47 条
[11]   Microchip-electrochemistry route for rapid screening of hydroquinone and arbutin from miscellaneous samples:: Investigation of the robustness of a simple cross-injector system [J].
Crevillén, AG ;
Barrigas, I ;
Blasco, AJ ;
González, MC ;
Escarpa, A .
ANALYTICA CHIMICA ACTA, 2006, 562 (02) :137-144
[12]   Simultaneous determination of derivatized light aldehydes by microchip electrophoresis with electrochemical detection [J].
Dossi, Nicolo ;
Susmel, Sabina ;
Toniolo, Rosanna ;
Pizzariello, Andrea ;
Bontempelli, Gino .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1207 (1-2) :169-174
[13]   Rapid analysis of azo-dyes in food by microchip electrophoresis with electrochemical detection [J].
Dossi, Nicolo ;
Piccin, Evandro ;
Bontempelli, Gino ;
Carrilho, Emanuel ;
Wang, Joseph .
ELECTROPHORESIS, 2007, 28 (22) :4240-4246
[14]  
Dou YH, 2002, ELECTROPHORESIS, V23, P3558, DOI 10.1002/1522-2683(200210)23:20<3558::AID-ELPS3558>3.0.CO
[15]  
2-#
[16]   Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips [J].
Effenhauser, CS ;
Bruin, GJM ;
Paulus, A ;
Ehrat, M .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3451-3457
[17]   Charge-coupled device operated in a time-delayed integration mode as an approach to high-throughput flow-based single molecule analysis [J].
Emory, Jason M. ;
Soper, Steven A. .
ANALYTICAL CHEMISTRY, 2008, 80 (10) :3897-3903
[18]   Chiral separations on multichannel microfluidic chips [J].
Gao, Y ;
Shen, Z ;
Wang, H ;
Dai, ZP ;
Lin, BC .
ELECTROPHORESIS, 2005, 26 (24) :4774-4779
[19]   Comparison of surfactants for dynamic surface modification of poly(dimethylsiloxane) microchips [J].
Garcia, CD ;
Dressen, BM ;
Henderson, A ;
Henry, CS .
ELECTROPHORESIS, 2005, 26 (03) :703-709
[20]   Electrochromatography in microchips packed with conventional reversed-phase silica particles [J].
Gaspar, Attila ;
Hernandez, Lilia ;
Stevens, Schetema ;
Gomez, Frank A. .
ELECTROPHORESIS, 2008, 29 (08) :1638-1642