Scanning electron microscope study on the efficacy of root canal wall debridement of hand versus Lightspeed instrumentation

被引:24
作者
Bechelli, C
Orlandini, SZ
Colafranceschi, M
机构
[1] Univ Florence, Inst Pathol, Florence, Italy
[2] Univ Florence, Dept Human Anat & Histol, Florence, Italy
关键词
canal debridement; hand instrumentation; LightSpeed (TM); mechanical instrumentation; scanning electron microscopy;
D O I
10.1046/j.1365-2591.1999.00250.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The aim of this in vitro study was to compare the efficacy of root canal wall debridement following hand versus LightSpeed(TM) instrumentation. Methodology Twenty recently extracted single-rooted teeth were paired and randomly placed into two treatment groups of 10 teeth each. In group 1, a step-rooted instrumentation without: initial coronal flaring with stainless steel Hedstroem fries was used; group 2 was instrumented with Ni-Ti LightSpeed(TM) instruments, Both groups had the same irrigation regimen: 2.5% NaOCl and a 15% EDTA solution, The teeth were then decoronated and each root split longitudinally inter two halves to be examined using the scanning; electron microscope (SEM). The presence of superficial debris and smear layer was evaluated by a standardized grading system, and the resulting scores submitted to nonparametric statistics. Results Under the conditions of this study, the removal of superficial debris was generally excellent with both canal preparation. techniques resulted in variable presence of residual smear layer, with a canal wall covered by smear layer as the predominant characteristic. Generally, the amount of smear layer was greater in the apical than in the middle third of the root, however, this difference was statistically significant (P < 0.005) only in hand-instrumented teeth. The use of LightSpeed(TM) instruments was associated with significantly more (P < 0.05) smear layer presence in the middle region of the root when compared with hand instrumentation. In addition, less smear layer was present in the apical region following LightSpeed(TM) instrumentation than stainless steel hand files, but this difference was not statistically significant. Differences in debridement between the two halves of the same root were more evident with LightSpeed(TM) than manual instrumentation, however, there was no statistical significance. Conclusions It may be inferred that the choice between hand and LightSpeed(TM) instrumentation should be based on factors other than the amount of root canal debridement, which does not vary significantly according to the instruments used.
引用
收藏
页码:484 / 493
页数:10
相关论文
共 25 条
[11]   SCANNING ELECTRON-MICROSCOPY OF INSTRUMENTED, IRRIGATED AND FILLED ROOT CANALS [J].
LESTER, KS ;
BOYDE, A .
BRITISH DENTAL JOURNAL, 1977, 143 (11) :359-367
[12]   The effectiveness of three irrigating solutions on root canal cleaning after hand and mechanical preparation [J].
Liolios, E ;
Economides, N ;
PArissisMessimeris, S ;
Boutsioukis, A .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :51-57
[13]   Root-end cavity preparation using the MicroMega sonic Retro-prep Tip(TM). SEM analysis [J].
Lloyd, A ;
Jaunberzins, A ;
Dummer, PMH ;
Bryant, S .
INTERNATIONAL ENDODONTIC JOURNAL, 1996, 29 (05) :295-301
[14]   SCANNING ELECTRON-MICROSCOPIC INVESTIGATION OF THE SMEARED LAYER ON ROOT-CANAL WALLS [J].
MADER, CL ;
BAUMGARTNER, JC ;
PETERS, DD .
JOURNAL OF ENDODONTICS, 1984, 10 (10) :477-483
[15]  
Mizrahi S J, 1975, J Endod, V1, P324, DOI 10.1016/S0099-2399(75)80012-4
[16]   COMPARISON OF CANAL PREPARATIONS IN STRAIGHT AND CURVED ROOT CANALS [J].
SCHNEIDER, SW .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1971, 32 (02) :271-+
[17]   THE SMEAR LAYER - A PHENOMENON IN ROOT-CANAL THERAPY [J].
SEN, BH ;
WESSELINK, PR ;
TURKUN, M .
INTERNATIONAL ENDODONTIC JOURNAL, 1995, 28 (03) :141-148
[18]  
SHOHA SD, 1996, J ENDODONT, V22, P194
[19]   FACTORS INFLUENCING THE SUCCESS OF CONVENTIONAL ROOT-CANAL THERAPY - A 5-YEAR RETROSPECTIVE STUDY [J].
SMITH, CS ;
SETCHELL, DJ ;
HARTY, FJ .
INTERNATIONAL ENDODONTIC JOURNAL, 1993, 26 (06) :321-333
[20]   Shaping ability of ProFile.04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals .2. [J].
Thompson, SA ;
Dummer, PMH .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :8-15