Direct electrochemistry and biosensing of hydrogen peroxide of horseradish peroxidase immobilized at multiwalled carbon nanotube/alumina-coated silica nanocomposite modified glassy carbon electrode

被引:41
作者
Huang, Jian-Lung [1 ]
Tsai, Yu-Chen [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem Engn, Taichung 402, Taiwan
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2009年 / 140卷 / 01期
关键词
Direct electron transfer; Horseradish peroxidase; Multiwalled carbon nanotubes; Alumina-coated silica; GLUCOSE-OXIDASE; HEME-PROTEINS; ELECTROCATALYSIS; NANOTUBES; CHITOSAN; FILMS; HEMOGLOBIN; POWDER;
D O I
10.1016/j.snb.2009.04.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Direct electrochemistry and bioelectrocatalytic ability toward the reduction of hydrogen peroxide of horseradish peroxidase (HRP) were found at the multiwalled carbon nanotube/alumina-coated silica (MWCNT/ACS) nanocomposite modified glassy carbon electrode. The surface morphology of the HRP/MWCNT/ACS nanobiocomposite modified glassy carbon electrode was characterized by scanning electron microscopy. In cyclic voltammetric response, the immobilized HRP at the MWCNT/ACS nanocomposite modified glassy carbon electrode displayed a pair of well-defined and quasi-reversible redox peaks with a formal potential of -0.328V versus Ag/AgCl at a scan rate of 200 mV s(-1). The formal potential of HRP varied linearly in the range of solution pH values from 6.0 to 8.0 with a slope of -56 mV pH(-1), which is close to the theoretical value of -59 mV pH(-1) fora reversible one-electron coupled with one-proton electrochemical reaction process. Several important experimental variables were optimized. The optimized hydrogen peroxide biosensor exhibited a sensitivity of 0.157 A M-1 cm(-2), a detection limit of 0.63 mu M, a linear range of 1-500 mu M, and an apparent Michaelis-Menten constant of 0.39 mM. The performance of the prepared biosensor was evaluated with respect to four possible interferences. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 39 条
[11]   Direct peroxidase bioelectrocatalysis on a variety of electrode materials [J].
Ferapontova, EE .
ELECTROANALYSIS, 2004, 16 (13-14) :1101-1112
[12]   A hydrogen peroxide biosensor based on direct electrochemistry of hemoglobin incorporated in PEO-PPO-PEO triblock copolymer film [J].
Jia, Nengqin ;
Lian, Qiong ;
Wang, Zhiyong ;
Shen, Hebai .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (01) :230-234
[13]   GENERAL EXPRESSION OF THE LINEAR POTENTIAL SWEEP VOLTAMMOGRAM IN THE CASE OF DIFFUSIONLESS ELECTROCHEMICAL SYSTEMS [J].
LAVIRON, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 101 (01) :19-28
[14]   Heme protein-gluten films: voltammetric studies and their electrocatalytic properties [J].
Liu, HY ;
Hu, NF .
ANALYTICA CHIMICA ACTA, 2003, 481 (01) :91-99
[15]   Electrochemical characteristics of heme proteins in hydroxyethylcellulose film [J].
Liu, XJ ;
Chen, T ;
Liu, LF ;
Li, GX .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (01) :106-111
[16]   Basal plane pyrolytic graphite modified electrodes: Comparison of carbon nanotubes and graphite powder as electrocatalysts [J].
Moore, RR ;
Banks, CE ;
Compton, RG .
ANALYTICAL CHEMISTRY, 2004, 76 (10) :2677-2682
[17]   Composite film of carbon nanotubes and chitosan for preparation of amperometric hydrogen peroxide biosensor [J].
Qian, L ;
Yang, XR .
TALANTA, 2006, 68 (03) :721-727
[18]   KINETIC-MODELS OF HORSERADISH-PEROXIDASE ACTION ON A GRAPHITE ELECTRODE [J].
RUZGAS, T ;
GORTON, L ;
EMNEUS, J ;
MARKOVARGA, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 391 (1-2) :41-49
[19]   Iron oxide particles are the active sites for hydrogen peroxide sensing at multiwalled carbon nanotube modified electrodes [J].
Sljukic, Biljana ;
Banks, Craig E. ;
Compton, Richard G. .
NANO LETTERS, 2006, 6 (07) :1556-1558
[20]   A novel hydrogen peroxide sensor based on horseradish peroxidase immobilized in DNA films on a gold electrode [J].
Song, YH ;
Wang, L ;
Ren, CB ;
Zhu, GY ;
Li, Z .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (02) :1001-1006