Amperometric glucose biosensor based on adsorption of glucose oxidase at platinum nanoparticle-modified carbon nanotube electrode

被引:262
作者
Tang, H
Chen, JH [1 ]
Yao, SZ
Nie, LH
Deng, GH
Kuang, YF
机构
[1] Hunan Univ, State Key Lab Chem Biosensing & Chemometr, Changsha 410082, Peoples R China
[2] Hunan Univ, Coll Chem & Chem Engn, Changsha 410082, Peoples R China
关键词
carbon nanotubes; platinum nanoparticle; Nafion; glucose oxidase; biosensor;
D O I
10.1016/j.ab.2004.05.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new amperometric biosensor, based on adsorption of glucose oxidase (GOD) at the platinum nanoparticle-modified carbon nanotube (CNT) electrode, is presented in this article. CNTs were grown directly on the graphite substrate. The resulting GOD/Pt/CNT electrode was covered by a thin layer of Nafion to avoid the loss of GOD in determination and to improve the anti-interferent ability. The morphologies and electrochemical performance of the CNT, Pt/CNT, and Nafion/GOD/Pt/CNT electrodes have been investigated by scanning electron microscopy, cyclic voltammetry, and amperometric methods. The excellent electrocatalytic activity and special three-dimensional structure of the enzyme electrode result in good characteristics such as a large determination range (0.1-13.5 mM), a short response time (within 5 s), a large current density (1.176mA cm(-2)), and high sensitivity (91 mA M-1 cm(-2)) and stability (73.5% remains after 22 days). In addition, effects of pH value, applied potential, electrode construction, and electroactive interferents on the amperometric response of the sensor were investigated and discussed. The reproducibility and applicability to whole blood analysis of the enzyme electrode were also evaluated. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:89 / 97
页数:9
相关论文
共 39 条
[31]   Amperometric glucose sensor based on glucose oxidase immobilized in electrochemically generated poly(ethacridine) [J].
Xu, JJ ;
Chen, HY .
ANALYTICA CHIMICA ACTA, 2000, 423 (01) :101-106
[32]   Amperometric glucose sensor based on coimmobilization of glucose oxidase and poly(p-phenylenediamine) at a platinum microdisk electrode [J].
Xu, JJ ;
Chen, HY .
ANALYTICAL BIOCHEMISTRY, 2000, 280 (02) :221-226
[33]  
Zhang XJ, 1999, ELECTROANAL, V11, P945, DOI 10.1002/(SICI)1521-4109(199909)11:13<945::AID-ELAN945>3.3.CO
[34]  
2-Z
[35]   Electrochemical sensors based on carbon nanotubes [J].
Zhao, Q ;
Gan, ZH ;
Zhuang, QK .
ELECTROANALYSIS, 2002, 14 (23) :1609-1613
[36]   Anodic oxidation of hydrazine at carbon nanotube powder microelectrode and its detection [J].
Zhao, YD ;
Zhang, WD ;
Chen, H ;
Luo, QM .
TALANTA, 2002, 58 (03) :529-534
[37]   Direct electron transfer of glucose oxidase molecules adsorbed onto carbon nanotube powder microelectrode [J].
Zhao, YD ;
Zhang, WD ;
Chen, H ;
Luo, QM .
ANALYTICAL SCIENCES, 2002, 18 (08) :939-941
[38]   A glucose biosensor based on microporous polyacrylonitrile synthesized by single rare-earth catalyst [J].
Zheng, H ;
Xue, HG ;
Zhang, YF ;
Shen, ZQ .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :541-545
[39]   Planar amperometric glucose sensor based on glucose oxidase immobilized by chitosan film on Prussian blue layer [J].
Zhu, JH ;
Zhu, ZQ ;
Lai, ZS ;
Wang, R ;
Guo, XM ;
Wu, XQ ;
Zhang, GX ;
Zhang, ZR ;
Zhang, ZR ;
Wang, YT ;
Chen, ZY .
SENSORS, 2002, 2 (04) :127-136