MALDI on a chip: Analysis of arrays of low femtomole to subfemtomole quantities of synthetic oligonucleotides and DNA diagnostic products dispensed by a piezoelectric pipet

被引:165
作者
Little, DP [1 ]
Cornish, TJ [1 ]
ODonnell, MJ [1 ]
Braun, A [1 ]
Cotter, RJ [1 ]
Koster, H [1 ]
机构
[1] JOHNS HOPKINS UNIV,SCH MED,DEPT PHARMACOL & MOL SCI,BALTIMORE,MD 21205
关键词
D O I
10.1021/ac970758+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A piezoelectric pipet is used to dispense arrays of low-nanoliter aliquots of matrix and DNA into individual etched wells on <1 in.(2) silicon chips prior to their semiautomated analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), Spectrum acquisition is expedited relative to conventional ''large-spot'' MALDI since the resulting miniaturized samples are approximately the same size as the irradiation area of the ionization/desorption laser; thus, searching for crystal regions from which intense analyte signals may be obtained is not necessary, Using a linear TOF instrument designed for scanning high-density arrays of samples, mass spectra from as little as 0.2 fmol (45 nM) of a 36-mer DNA have been acquired from single miniature elements, Spot-to-spot reproducibility from microdispensed samples is superior to that using conventional pipets; in less than 6 min, spectra with high signal-to-noise ratios were acquired from 100 elements containing 8 fmol of a 25-mer. Low-nanoliter quantities of DNA diagnostic products generated in primer oligo base extension reactions from PCR templates were transferred to chips and analyzed by MALDI-TOF MS, giving accurate genotyping results for single base mutations and short tandem repeat polymorphisms (microsatellites). These procedures provide enabling capabilities for extremely accurate high-throughput DNA diagnostics and sequencing based on mass spectrometry.
引用
收藏
页码:4540 / 4546
页数:7
相关论文
共 35 条
[21]   ANALYSIS OF ENZYMATIC DNA-SEQUENCING REACTIONS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY [J].
SHALER, TA ;
TAN, YP ;
WICKHAM, JN ;
WU, KJ ;
BECKER, CH .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (10) :942-947
[22]   Steric factors influencing hybridisation of nucleic acids to oligonucleotide arrays [J].
Shchepinov, MS ;
CaseGreen, SC ;
Southern, EM .
NUCLEIC ACIDS RESEARCH, 1997, 25 (06) :1155-1161
[23]   POLYMER SUPPORT OLIGONUCLEOTIDE SYNTHESIS .18. USE OF BETA-CYANOETHYL-N,N-DIALKYLAMINO-/N-MORPHOLINO PHOSPHORAMIDITE OF DEOXYNUCLEOSIDES FOR THE SYNTHESIS OF DNA FRAGMENTS SIMPLIFYING DEPROTECTION AND ISOLATION OF THE FINAL PRODUCT [J].
SINHA, ND ;
BIERNAT, J ;
MCMANUS, J ;
KOSTER, H .
NUCLEIC ACIDS RESEARCH, 1984, 12 (11) :4539-4557
[24]   ATTOMOLE BIOMOLECULE MASS ANALYSIS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE [J].
SOLOUKI, T ;
MARTO, JA ;
WHITE, FM ;
GUAN, SH ;
MARSHALL, AG .
ANALYTICAL CHEMISTRY, 1995, 67 (22) :4139-4144
[25]   ASSOCIATION BETWEEN A SPECIFIC APOLIPOPROTEIN-B MUTATION AND FAMILIAL DEFECTIVE APOLIPOPROTEIN-B-100 [J].
SORIA, LF ;
LUDWIG, EH ;
CLARKE, HRG ;
VEGA, GL ;
GRUNDY, SM ;
MCCARTHY, BJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (02) :587-591
[26]   MATRIX-ASSISTED LASER DESORPTION/IONIZATION MASS-SPECTROMETRY OF IMMOBILIZED DUPLEX DNA PROBES [J].
TANG, K ;
FU, DJ ;
KOTTER, S ;
COTTER, RJ ;
CANTOR, CR ;
KOSTER, H .
NUCLEIC ACIDS RESEARCH, 1995, 23 (16) :3126-3131
[27]   ATTOMOLE-SENSITIVITY ELECTROSPRAY SOURCE FOR LARGE-MOLECULE MASS-SPECTROMETRY [J].
VALASKOVIC, GA ;
KELLEHER, NL ;
LITTLE, DP ;
AASERUD, DJ ;
MCLAFFERTY, FW .
ANALYTICAL CHEMISTRY, 1995, 67 (20) :3802-3805
[28]   Attomole protein characterization by capillary electrophoresis mass spectrometry [J].
Valaskovic, GA ;
Kelleher, NL ;
McLafferty, FW .
SCIENCE, 1996, 273 (5279) :1199-1202
[29]   IMPROVED RESOLUTION AND VERY HIGH-SENSITIVITY IN MALDI TOF OF MATRIX SURFACES MADE BY FAST EVAPORATION [J].
VORM, O ;
ROEPSTORFF, P ;
MANN, M .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3281-3287
[30]   USE OF SMALL-DIAMETER CAPILLARIES FOR INCREASING PEPTIDE AND PROTEIN-DETECTION SENSITIVITY IN CAPILLARY-ELECTROPHORESIS MASS-SPECTROMETRY [J].
WAHL, JH ;
GOODLETT, DR ;
UDSETH, HR ;
SMITH, RD .
ELECTROPHORESIS, 1993, 14 (5-6) :448-457