ATTOMOLE-SENSITIVITY ELECTROSPRAY SOURCE FOR LARGE-MOLECULE MASS-SPECTROMETRY

被引:199
作者
VALASKOVIC, GA [1 ]
KELLEHER, NL [1 ]
LITTLE, DP [1 ]
AASERUD, DJ [1 ]
MCLAFFERTY, FW [1 ]
机构
[1] CORNELL UNIV,BAKER LAB CHEM,ITHACA,NY 14853
关键词
D O I
10.1021/ac00116a030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Full mass spectra of high resolving power are obtained from 0.2 nL sample volumes of large (>10 kDa) nucleotides and proteins using a new electrospray ionization (ESI) system combined with Fourier transform mass spectrometry. The ESI needles are fabricated by laser-heated pulling of fused-silica tubing (5-20 mu m i.d.), followed by chemical etching and surface metalization. Total analyte loaded at the instrument of 8.6 fmol and 216 amol produces signal-to-noise ratios of 400:1 and 60:1, respectively, and resolving power of >10(5) for full mass spectra, while the total amount of material consumed is similar to 150 and 10 amol, respectively.
引用
收藏
页码:3802 / 3805
页数:4
相关论文
共 30 条
[1]   MICRO-ELECTROSPRAY - ZEPTOMOLE-ATTOMOLE PER MICROLITER SENSITIVITY FOR PEPTIDES [J].
ANDREN, PE ;
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (09) :867-869
[2]   FOURIER-TRANSFORM ELECTROSPRAY INSTRUMENTATION FOR TANDEM HIGH-RESOLUTION MASS-SPECTROMETRY OF LARGE MOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
WAMPLER, FM ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :557-565
[3]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) :605-613
[4]   MASS-SPECTROMETRIC PEPTIDE AND PROTEIN CHARTING [J].
FEISTNER, GJ ;
FAULL, KF ;
BAROFSKY, DF ;
ROEPSTORFF, P .
JOURNAL OF MASS SPECTROMETRY, 1995, 30 (04) :519-530
[5]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[6]  
FOSKETT JK, 1990, NONINVASIVE TECHNIQU, V9
[7]   SMALL-VOLUME AND LOW FLOW-RATE ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF AQUEOUS SAMPLES [J].
GALE, DC ;
SMITH, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (11) :1017-1021
[8]   ANALYSIS OF SINGLE CELLS BY CAPILLARY ELECTROPHORESIS WITH ON COLUMN DERIVATIZATION AND LASER-INDUCED FLUORESCENCE DETECTION [J].
GILMAN, SD ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1995, 67 (01) :58-64
[9]  
Herman B., 1990, OPTICAL MICROSCOPY B, V1st
[10]  
Hillenkamp F, 1991, Anal Chem, V63, p1193A, DOI 10.1021/ac00024a002