Full Scan MS in Comprehensive Qualitative and Quantitative Residue Analysis in Food and Feed Matrices: How Much Resolving Power is Required?

被引:155
作者
Kellmann, Markus [1 ]
Muenster, Helmut [1 ]
Zomer, Paul [2 ]
Mol, Hans [2 ]
机构
[1] Thermo Fisher Sci, D-28199 Bremen, Germany
[2] RIKILT Inst Food Safety, Wageningen, Netherlands
关键词
FLIGHT MASS-SPECTROMETRY; VETERINARY DRUGS; ACCURACY;
D O I
10.1016/j.jasms.2009.05.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In LC full scan based MS screening methods correct mass assignment is essential. Parameters affecting the accuracy of mass assignment, i.e., analyte concentration, complexity of the matrix, and resolving power, were studied using typical examples from the field of residue and contaminant analysis in food and feed. The evaluation was carried out by analyzing samples of honey and animal feed, spiked with 151 pesticides, veterinary drugs, mycotoxins, and plant toxins at levels ranging from 10 to 250 ng/g. Analyses were performed using a single stage Orbitrap with resolving power settings varying from 10,000 to 100,000 (FWHM). For consistent and reliable mass assignment (<2 ppm) of analytes at low levels in complex matrices, a high resolving power (>= 50, 000) was found to be required. At lower resolving power settings, the error in the assignment of mass increased due to the coelution of analytes with interferences at the same nominal mass. This negatively affected selectivity and quantitative performance due to the inability to use the required narrow mass-extraction windows. In the case of the less complex honey matrix, a resolving power of 25,000 was generally sufficient to obtain a mass assignment error close to the typical instrument mass accuracy (<= 2 ppm) down to low concentration levels of 10 ng/g. (J Am Soc Mass Spectrom 2009,20,1464-1476) (C) 2009 Published by Elsevier Inc. on behalf of American Society for Mass Spectrometry
引用
收藏
页码:1464 / 1476
页数:13
相关论文
共 22 条
[11]   Screening and confirmation criteria for hormone residue analysis using liquid chromatography accurate mass time-of-flight, Fourier transform ion cyclotron resonance and orbitrap mass spectrometry techniques [J].
Nielen, M. W. F. ;
van Engelen, M. C. ;
Zuiderent, R. ;
Ramaker, R. .
ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) :122-129
[12]   Parts per million mass accuracy on an orbitrap mass spectrometer via lock mass injection into a C-trap [J].
Olsen, JV ;
de Godoy, LMF ;
Li, GQ ;
Macek, B ;
Mortensen, P ;
Pesch, R ;
Makarov, A ;
Lange, O ;
Horning, S ;
Mann, M .
MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (12) :2010-2021
[13]   ORBITRAP MASS SPECTROMETRY: INSTRUMENTATION, ION MOTION AND APPLICATIONS [J].
Perry, Richard H. ;
Cooks, R. Graham ;
Noll, Robert J. .
MASS SPECTROMETRY REVIEWS, 2008, 27 (06) :661-699
[14]   Orbitrap mass analyzer - Overview and applications in proteomics [J].
Scigelova, Michaela ;
Makarov, Alexander .
PROTEOMICS, 2006, :16-21
[15]   Comprehensive screening and quantification of veterinary drugs in milk using UPLC-ToF-MS [J].
Stolker, A. A. M. ;
Rutgers, P. ;
Oosterink, E. ;
Lasaroms, J. J. P. ;
Peters, R. J. B. ;
van Rhijn, J. A. ;
Nielen, M. W. F. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (06) :2309-2322
[16]  
Thurman EM, 2006, ANAL CHEM, V78, P6702
[17]  
*USDA, 2009, MAX RES LIM DAT
[18]   Full-Scan Accurate Mass Selectivity of Ultra-Performance Liquid Chromatography Combined with Time-of-Flight and Orbitrap Mass Spectrometry in Hormone and Veterinary Drug Residue Analysis [J].
van der Heeft, E. ;
Bolck, Y. J. C. ;
Beumer, B. ;
Nijrolder, A. W. J. M. ;
Stolker, A. A. M. ;
Nielen, M. W. F. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (03) :451-463
[19]  
2002, OFFICIAL J EUROPEAN, V30
[20]  
2006, OFFICIAL J EUROPEAN, V20, pL264