Comprehensive screening and quantification of veterinary drugs in milk using UPLC-ToF-MS

被引:182
作者
Stolker, A. A. M. [1 ]
Rutgers, P. [1 ]
Oosterink, E. [1 ]
Lasaroms, J. J. P. [1 ]
Peters, R. J. B. [1 ]
van Rhijn, J. A. [2 ]
Nielen, M. W. F. [1 ,3 ]
机构
[1] Wageningen UR, RIKILT Inst Food Safety, NL-6700 AE Wageningen, Netherlands
[2] Food & Consumer Prod Safety Author, Lab Reg E, NL-6708 PD Wageningen, Netherlands
[3] Wageningen Univ, Organ Chem Lab, NL-6703 HB Wageningen, Netherlands
关键词
multi-class; multi-residue; full scan; validation; 2002/657/EC; time-of-flight;
D O I
10.1007/s00216-008-2168-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ultra-performance liquid chromatography combined with time-of-flight mass spectrometry (UPLC-ToF-MS) has been used for screening and quantification of more than 100 veterinary drugs in milk. The veterinary drugs represent different classes including benzimidazoles, macrolides, penicillins, quinolones, sulphonamides, pyrimidines, tetracylines, nitroimidazoles, tranquillizers, ionophores, amphenicols and non-steroidal anti-inflammatory agents (NSAIDs). After protein precipitation, centrifugation and solid-phase extraction (SPE), the extracts were analysed by UPLC-ToF-MS. From the acquired full scan data the drug-specific ions were extracted for construction of the chromatograms and evaluation of the results. The analytical method was validated according to the EU guidelines (2002/657/EC) for a quantitative screening method. At the concentration level of interest (MRL level) the results for repeatability (%RSD < 20% for 86% of the compounds), reproducibility (%RSD < 40% for 96% of the compounds) and the accuracy (80-120% for 88% of the compounds) were satisfactory. Evaluation of the CC beta values and the linearity results demonstrates that the developed method shows adequate sensitivity and linearity to provide quantitative results. Furthermore, the method is accurate enough to differentiate between suspected and negative samples or drug concentrations below or above the MRL. A set of 100 samples of raw milk were screened for residues. No suspected (positive) results were obtained except for the included blind reference sample containing sulphamethazine (88 mu g/l) that tested positive for this compound. UPLC-ToF-MS combines high resolution for both LC and MS with high mass accuracy which is very powerful for the multi-compound analysis of veterinary drugs. The technique seems to be powerful enough for the analysis of not only veterinary drugs but also organic contaminants like pesticides, mycotoxins and plant toxins in one single method.
引用
收藏
页码:2309 / 2322
页数:14
相关论文
共 15 条
[1]   Matrix effects on accurate mass measurements of low-molecular weight compounds using liquid chromatography-electrospray-quadrupole time-of-flight mass spectrometry [J].
Calbiani, F ;
Careri, M ;
Elviri, L ;
Mangia, A ;
Zagnoni, I .
JOURNAL OF MASS SPECTROMETRY, 2006, 41 (03) :289-294
[2]   Review of methodology for the determination of benzimidazole residues in biological matrices [J].
Danaher, Martin ;
De Ruyck, Hendrik ;
Crooks, Steven R. H. ;
Dowling, Geraldine ;
O'Keeffe, Michael .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 845 (01) :1-37
[3]   Large scale pesticide multiresidue methods in food combining liquid chromatography-time-of-flight mass spectrometry and tandem mass Spectrometry [J].
Garcia-Reyes, Juan F. ;
Hernando, M. Dolores ;
Ferrer, Carmen ;
Molina-Diaz, Antonio ;
Fernandez-Alba, Amadeo R. .
ANALYTICAL CHEMISTRY, 2007, 79 (19) :7308-7323
[4]   Rapid multi-residue screening of antibiotics in muscle and kidney by liquid chromatography-electrospray ionization-tandem mass spectrometry [J].
Granelli, K. ;
Branzell, C. .
ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) :289-295
[5]   Ultra-performance liquid chromatography coupled to time of flight mass spectrometry (UPLC-TOF): A novel tool for multiresidue screening of veterinary drugs in urine [J].
Kaufmann, Anton ;
Butcher, Patrick ;
Maden, Kathryn ;
Widmer, Mirjam .
ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) :13-21
[6]   Strategies to avoid false negative findings in residue analysis using liquid chromatography coupled to time-of-flight mass spectrometry [J].
Kaufmann, Anton ;
Butcher, Patrick .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (23) :3566-3572
[7]   Investigation into the factors affecting accuracy of mass measurements on a time-of-flight mass spectrometer using Design of Experiment [J].
Laures, Alice M. -F. ;
Wolff, Jean-Claude ;
Eckers, Christine ;
Borman, Phil J. ;
Chatfield, Marion J. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (04) :529-535
[8]  
MOL HJM, 2008, ANAL BIOANA IN PRESS
[9]   A versatile liquid chromatography-tandem mass spectrometry system for the analysis of different groups of veterinary drugs [J].
Muñoz, P ;
Blanca, J ;
Ramos, A ;
Bartolomé, M ;
García, E ;
Méndez, N ;
Gomez, J ;
de Pozuelo, MM .
ANALYTICA CHIMICA ACTA, 2005, 529 (1-2) :137-144
[10]   Screening and confirmation criteria for hormone residue analysis using liquid chromatography accurate mass time-of-flight, Fourier transform ion cyclotron resonance and orbitrap mass spectrometry techniques [J].
Nielen, M. W. F. ;
van Engelen, M. C. ;
Zuiderent, R. ;
Ramaker, R. .
ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) :122-129