Direct reconstruction of the Vienna applicator on MR images

被引:41
作者
Berger, Daniel [1 ]
Dimopoulos, Johannes [1 ]
Poetter, Richard [1 ]
Kirisits, Christian [1 ]
机构
[1] Med Univ Vienna, Gen Hosp Vienna, Dept Radiotherapy, Vienna, Austria
关键词
Brachytherapy; Applicator reconstruction; Vienna ring applicator; Cervical cancer; Modern treatment planning systems; CERVIX CANCER BRACHYTHERAPY; INTRACAVITARY BRACHYTHERAPY; INTERSTITIAL BRACHYTHERAPY; VOLUME PARAMETERS; RECOMMENDATIONS; RADIOTHERAPY; ACCURACY; TERMS;
D O I
10.1016/j.radonc.2009.07.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To introduce and test a direct reconstruction concept for intracavitary tandem ring applicators in MR image based brachytherapy treatment planning. Materials and Methods: Optical measurements of transparent ring-phantoms provided the geometric relation between source path and the Vienna ring applicator as visible on MRI. For the manual direct reconstruction method (PLATO), the geometry plotted on a transparency was placed on the screen and rotated to fit with visible ring holes. With the software-integrated reconstruction method (OncentraGYN), the applicator geometry was directly used when placing the visible parts of the applicator in the 3D dataset. Clinical feasibility was tested in 10 clinical insertions. Reconstruction and dose calculation were performed independently on two treatment planning systems (PLATO and OncentraGYN) using MRI alone. DVH-parameters for targets and organs at risk were analysed and compared to the clinically used radiograph / MRI registration based method. Results: The direct reconstruction concept for both methods was feasible and reduced treatment planning time. Evaluated DVH-parameters for plans using direct reconstruction methods differed from clinically used plans (traditional reconstruction) in mean-differences <= 0.2Gy for plans with 7 Gy prescribed dose. Conclusion: If the relation between applicator shape visible on MRI and the source path is defined once, the reconstruction process can be performed by directly placing the applicator in the MRI dataset. (C) 2009 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 93 (2009) 347-351
引用
收藏
页码:347 / 351
页数:5
相关论文
共 19 条
[1]   Inverse planning approach for 3-D MRI-based pulse-dose rate intracavitary brachytherapy in cervix cancer [J].
Chajon, Enrique ;
Dumas, Isabelle ;
Touleimat, Mahmoud ;
Magne, Nicolas ;
Coulot, Jeremy ;
Verstraet, Rodolfe ;
Lefkopoulos, Dimitri ;
Haie-Meder, Christine .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03) :955-961
[2]   The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer:: Clinical feasibility and preliminary results [J].
Dimopoulos, Johannes C. A. ;
Kirisits, Christian ;
Petric, Primoz ;
Georg, Petra ;
Lang, Stefan ;
Berger, Daniel ;
Poetter, Richard .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (01) :83-90
[3]   Comparison of radiography- and computed tomography-based treatment planning in cervix cancer in brachytherapy with specific attention to some quality assurance aspects [J].
Fellner, C ;
Pötter, R ;
Knocke, TH ;
Wambersie, A .
RADIOTHERAPY AND ONCOLOGY, 2001, 58 (01) :53-62
[4]   Aspects of MR image distortions in radiotherapy treatment planning [J].
Fransson, A ;
Andreo, P ;
Pötter, R .
STRAHLENTHERAPIE UND ONKOLOGIE, 2001, 177 (02) :59-73
[5]   Applicator reconstruction in MRI 3D image-based dose planning of brachytherapy for cervical cancer [J].
Haack, Soren ;
Nielsen, Soren Kynde ;
Lindegaard, Jacob Christian ;
Gelineck, John ;
Tanderup, Kari .
RADIOTHERAPY AND ONCOLOGY, 2009, 91 (02) :187-193
[6]   Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group* (I):: concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV [J].
Haie-Meder, C ;
Pötter, R ;
Van Limbergen, E ;
Briot, E ;
De Brabandere, M ;
Dimopoulos, J ;
Dumas, I ;
Hellebust, TP ;
Kirisits, C ;
Lang, SF ;
Muschitz, S ;
Nevinson, J ;
Nulens, A ;
Petrow, P ;
Wachter-Gerstner, N .
RADIOTHERAPY AND ONCOLOGY, 2005, 74 (03) :235-245
[7]   Reconstruction of a ring applicator using CT imaging: impact of the reconstruction method and applicator orientation [J].
Hellebust, Taran Paulsen ;
Tanderup, Kari ;
Bergstrand, Eva Stabell ;
Knutsen, Bjorn Helge ;
Roislien, Jo ;
Olsen, Dag Rune .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (16) :4893-4904
[8]   The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer:: Design, application, treatment planning, and dosimetric results [J].
Kirisits, C ;
Lang, S ;
Dimopoulos, J ;
Berger, D ;
Georg, D ;
Pötter, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :624-630
[9]   Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer [J].
Kirisits, C ;
Pötter, R ;
Lang, S ;
Dimopoulos, J ;
Wachter-Gerstner, N ;
Georg, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03) :901-911
[10]   Accuracy of volume and DVH parameters determined with different brachytherapy treatment planning systems [J].
Kirisits, Christian ;
Siebert, Frank-Andre ;
Baltas, Dimos ;
De Brabandere, Marisol ;
Hellebust, Taran Paulsen ;
Berger, Daniel ;
Venselaar, Jack .
RADIOTHERAPY AND ONCOLOGY, 2007, 84 (03) :290-297