Optical coherence tomography study of healing characteristics of paclitaxel-eluting balloons vs. everolimus-eluting stents for in-stent restenosis: the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) randomised clinical trial

被引:66
作者
Adriaenssens, Tom [1 ,2 ]
Dens, Jo [3 ]
Ughi, Giovanni [1 ,2 ]
Bennett, Johan [1 ,2 ]
Dubois, Christophe [1 ,2 ]
Sinnaeve, Peter [1 ,2 ]
Wiyono, Stefanus [1 ,2 ]
Coosemans, Mark [1 ,2 ]
Belmans, Ann [1 ,2 ]
D'hooge, Jan [1 ,2 ]
Vrolix, Mathias [3 ]
Desmet, Walter [1 ,2 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Dis, Univ Hosp Leuven, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[3] ZOL Hosp Genk, Genk, Belgium
关键词
drug-eluting balloon; drug-eluting stent; in-stent restenosis; optical coherence tomography; percutaneous coronary intervention; stent coverage; BARE-METAL STENTS; COATED BALLOON; FOLLOW-UP; VASCULAR BRACHYTHERAPY; MYOCARDIAL-INFARCTION; NEOINTIMAL COVERAGE; ANGIOPLASTY; NEOATHEROSCLEROSIS; ANGIOGRAPHY; PREVENTION;
D O I
10.4244/EIJV10I4A77
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Little is known about the respective healing responses and clinical efficacy and safety of drug-eluting balloons (DEB) and the second generation of drug-eluting stents (DES) when used to treat in-stent restenosis (ISR). In this study, we set out to compare prospectively the healing characteristics, as assessed by optical coherence tomography (OCT), of DEB versus DES after treatment of ISR in bare metal stents (BMS). Methods and results: Fifty patients with BMS ISR were randomised to treatment with a paclitaxel-eluting balloon vs. an everolimus-eluting stent (EES). The primary endpoint was the percentage of uncovered struts, assessed with OCT at nine months, as a marker of vessel wall healing. A mean of 366 +/- 135 and 636 +/- 184 struts were analysed per patient in the DEB and EES groups, respectively. The percentage of uncovered struts per patient was significantly lower with DEB vs. EES (1.4% vs. 3.1%, p=0.025). Mean neointimal hyperplasia area was 2.4 +/- 1.08 mm(2) in DEB vs. 1.92 +/- 0.67 mm(2) in EES (p=0.1806), while the percentage of malapposed struts per patient was very low in both groups (0.2% vs. 0.3%, p=0.699). At nine months, angiographic in-stent MLD (minimum lumen diameter) was lower (2.13 vs. 2.54 mm, p=0.006), while diameter stenosis (26.4 vs. 11.4%, p=0.002), and LLL (0.28 vs. 0.07 mm, p=0.1) were higher after DEB compared to EES. During one-year follow-up, we did not observe differences in the rates of death, TLR (target lesion revascularisation) or stent thrombosis. Conclusions: DEB appears to be associated with better healing characteristics, as assessed by stent strut coverage with OCT, but tended to be slightly less effective compared to EES. These findings give support to the use of either DEB or EES as valuable treatment options for ISR.
引用
收藏
页码:439 / 448
页数:10
相关论文
共 34 条
[1]  
Adriaenssens T, 2011, EUROINTERVENTION, V7, pK100, DOI 10.4244/EIJV7SKA17
[2]   Serial Morphological and Functional Assessment of Drug-Eluting Balloon for In-Stent Restenotic Lesions Mechanisms of Action Evaluated With Angiography, Optical Coherence Tomography, and Fractional Flow Reserve [J].
Agostoni, Pierfrancesco ;
Belkacemi, Anouar ;
Voskuil, Michiel ;
Nathoe, Hendrik M. ;
Doevendans, Pieter A. ;
Stella, Pieter R. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (06) :569-576
[3]   A randomized comparison of sirolimus-eluting stent with balloon angioplasty in patients with in-stent restenosis -: Results of the restenosis intrastent:: Balloon angioplasty versus elective sirolimus-eluting stenting (RIBS-II) trial [J].
Alfonso, Fernando ;
Perez-Vizcayno, Maria-Jose ;
Hernandez, Rosana ;
Bethencourt, Armando ;
Marti, Vicens ;
Lopez-Minguez, Jose R. ;
Angel, Juan ;
Mantilla, Ramon ;
Moris, Cesar ;
Cequier, Angel ;
Sabate, Manel ;
Escaned, Javier ;
Moreno, Raul ;
Bañuelos, Camino ;
Suarez, Alfonso ;
Macaya, Carlos .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (11) :2152-2160
[4]   Five-year follow-up of the Sirolimus-Eluting Stents vs Vascular Brachytherapy for Bare Metal In-Stent Restenosis (SISR) trial [J].
Alli, Oluseun O. ;
Teirstein, Paul S. ;
Satler, Lowell ;
Sketch, Michael H., Jr. ;
Popma, Jeffery J. ;
Mauri, Laura ;
Wang, Hong ;
Schleckser, Patricia A. ;
Cohen, Sidney A. ;
Holmes, David R., Jr. .
AMERICAN HEART JOURNAL, 2012, 163 (03) :438-445
[5]   Intracoronary Optical Coherence Tomography: A Comprehensive Review Clinical and Research Applications [J].
Bezerra, Hiram G. ;
Costa, Marco A. ;
Guagliumi, Giulio ;
Rollins, Andrew M. ;
Simon, Daniel I. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (11) :1035-1046
[6]   Paclitaxel-eluting balloons, paclitaxel-eluting stents, and balloon angioplasty in patients with restenosis after implantation of a drug-eluting stent (ISAR-DESIRE 3): a randomised, open-label trial [J].
Byrne, Robert A. ;
Neumann, Franz-Josef ;
Mehilli, Julinda ;
Pinieck, Susanne ;
Wolff, Britta ;
Tiroch, Klaus ;
Schulz, Stefanie ;
Fusaro, Massimiliano ;
Ott, Ilka ;
Ibrahim, Tareq ;
Hausleiter, Joerg ;
Valina, Christian ;
Pache, Juergen ;
Laugwitz, Karl-Ludwig ;
Massberg, Steffen ;
Kastrati, Adnan .
LANCET, 2013, 381 (9865) :461-467
[7]   Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: comparison with sirolimus-eluting stent using optical coherence tomography [J].
Choi, Hyun Hee ;
Kim, Jung-Sun ;
Yoon, Duck Hyoung ;
Hong, Kyung-Soon ;
Kim, Tae Hoon ;
Kim, Byeong Keuk ;
Ko, Young-Guk ;
Choi, Donghoon ;
Jang, Yangsoo ;
Hong, Myeong-Ki .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (03) :491-497
[8]   Strut Coverage and Late Malapposition With Paclitaxel-Eluting Stents Compared With Bare Metal Stents in Acute Myocardial Infarction Optical Coherence Tomography Substudy of the Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) Trial [J].
Guagliumi, Giulio ;
Costa, Marco A. ;
Sirbu, Vasile ;
Musumeci, Giuseppe ;
Bezerra, Hiram G. ;
Suzuki, Nobuaki ;
Matiashvili, Aleksandre ;
Lortkipanidze, Nikoloz ;
Mihalcsik, Laurian ;
Trivisonno, Antonio ;
Valsecchi, Orazio ;
Mintz, Gary S. ;
Dressler, Ovidiu ;
Parise, Helen ;
Maehara, Akiko ;
Cristea, Ecaterina ;
Lansky, Alexandra J. ;
Mehran, Roxana ;
Stone, Gregg W. .
CIRCULATION, 2011, 123 (03) :274-281
[9]   Strut Coverage and Vessel Wall Response to Zotarolimus-Eluting and Bare-Metal Stents Implanted in Patients With ST-Segment Elevation Myocardial Infarction The OCTAMI (Optical Coherence Tomography in Acute Myocardial Infarction) Study [J].
Guagliumi, Giulio ;
Sirbu, Vasile ;
Bezerra, Hiram ;
Biondi-Zoccai, Giuseppe ;
Fiocca, Luigi ;
Musumeci, Giuseppe ;
Matiashvili, Aleksandre ;
Lortkipanidze, Nikoloz ;
Tahara, Satoko ;
Valsecchi, Orazio ;
Costa, Marco .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (06) :680-687
[10]   Paclitaxel-coated balloon in combination with bare metal stent for treatment of de novo coronary lesions: an optical coherence tomography first-in-human randomised trial, balloon first vs. stent first [J].
Gutierrez-Chico, Juan Luis ;
van Geuns, Robert Jan ;
Koch, Karel T. ;
Koolen, Jacques J. ;
Duckers, Henricus ;
Regar, Evelyn ;
Serruys, Patrick W. .
EUROINTERVENTION, 2011, 7 (06) :711-722