A soft and flexible biosensor using a phospholipid polymer for continuous glucose monitoring

被引:27
作者
Chu, MingXing [2 ]
Kudo, Hiroyuki [1 ]
Shirai, Takayuki [3 ]
Miyajima, Kumiko [1 ]
Saito, Hirokazu [1 ,4 ]
Morimoto, Nobuyuki [5 ,6 ]
Yano, Kazuyoshi [7 ]
Iwasaki, Yasuhiko [8 ]
Akiyoshi, Kazunari [5 ]
Mitsubayashi, Kohji [1 ]
机构
[1] Tokyo Med & Dent Univ, Dept Biomed Devices & Instrumentat, Inst Biomat & Bioengn, Chiyoda Ku, Tokyo 1010062, Japan
[2] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Chiyoda Ku, Tokyo 1010062, Japan
[3] Tokyo Univ Technol, Grad Sch, Tokyo 1920982, Japan
[4] Tokyo Natl Coll Technol, Dept Mech Engn, Tokyo 1930997, Japan
[5] Tokyo Med & Dent Univ, Dept Organ Mat, Inst Biomat & Bioengn, Chiyoda Ku, Tokyo 1010062, Japan
[6] Tohoku Univ, Dept Mat Proc, Grad Sch Engn, Sendai, Miyagi 9808579, Japan
[7] Tokyo Univ Technol, Sch Bion, Tokyo 1920982, Japan
[8] Kansai Univ, Dept Chem & Mat Engn, Fac Chem Mat & Bioengn, Suitasi, Osakafu 5648680, Japan
基金
日本学术振兴会;
关键词
Biosensor; Phospholipid polymer; Flexible; Glucose sensor; TEAR GLUCOSE; SENSOR; TISSUE; ELECTRODES;
D O I
10.1007/s10544-009-9300-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A flexible biosensor using a phospholipid polymer to immobilization of glucose oxidase (GOD) was fabricated and tested. At first, an enzyme membrane formed by immobilizing GOD onto a porous polytetrafluoroethylene (PTFE) membrane using the phospholipid polymer (2-methacryloyloxyethyl phosphorylcholine (MPC) copolymerized with 2-ethylhexylmethacrylate (EHMA) : PMEH) was evaluated. According to the result of amperometric measurement, average density of GOD to be immobilized was optimized to 38.9 units cm(-2). Temperature and pH dependences were also investigated. Then, a flexible glucose sensor was fabricated by immobilizing GOD onto a flexible hydrogen peroxide electrode using PMEH. The flexible glucose sensor showed a linear relationship between output currents and glucose concentration in 0.05-1.00 mmol L-1, with a correlation coefficient of 0.999. The calibration range covered the normal tear glucose level of 0.14-0.23 mmol L-1. This indicates that the flexible biosensor is considered to be useful for monitoring of glucose in tear fluids.
引用
收藏
页码:837 / 842
页数:6
相关论文
共 24 条
[11]   Determination of glucose in submicroliter samples by CE-LIF using precolumn or on-column enzymatic reactions [J].
Jin, Z ;
Chen, R ;
Colon, LA .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1326-1331
[12]   Active insulin infusion using optimal and derivative-weighted control [J].
Lam, ZH ;
Hwang, KS ;
Lee, JY ;
Chase, JG ;
Wake, GC .
MEDICAL ENGINEERING & PHYSICS, 2002, 24 (10) :663-672
[13]   Flexible biosensors on spirally rolled micro tube for cardiovascular in vivo monitoring [J].
Li, Chunyan ;
Han, Jungyoup ;
Ahn, Chong H. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10) :1988-1993
[14]   Continuous glucose monitoring in interstitial subcutaneous adipose tissue and skeletal muscle reflects excursions in cerebral cortex [J].
Nielsen, JK ;
Djurhuus, CB ;
Gravholt, CH ;
Carus, AC ;
Granild-Jensen, J ;
Orskov, H ;
Christiansen, JS .
DIABETES, 2005, 54 (06) :1635-1639
[15]   Miniaturized fiber-optic hybrid sensor for continuous glucose monitoring in subcutaneous tissue [J].
Pasic, Alen ;
Koehler, Hans ;
Klimant, Ingo ;
Schaupp, Lukas .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) :60-68
[16]   Highly reliable O-ring packaging concept for MEMS pressure sensors [J].
Pedersen, C ;
Jespersen, ST ;
Jacobsen, KW ;
Krog, JP ;
Christensen, C ;
Thomsen, E .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 115 (2-3) :617-627
[17]   Novel micromachined silicon sensor for continuous glucose monitoring [J].
Piechotta, G ;
Albers, J ;
Hintsche, R .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (05) :802-808
[18]   Toward continuous glucose monitoring with planar modified biosensors and microdialysis - Study of temperature, oxygen dependence and in vivo experiment [J].
Ricci, Francesco ;
Caprio, Felice ;
Poscia, Alessandro ;
Valgimigli, Francesco ;
Messeri, Dirnitri ;
Lepori, Elena ;
Dall'Oglio, Giorgio ;
Palleschi, Giuseppe ;
Moscone, Danila .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10) :2032-2039
[19]   Direct glucose determination in blood using a reagentless optical biosensor [J].
Sanz, Vanesa ;
de Marcos, Susana ;
Galban, Javier .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (12) :2876-2883
[20]   TEAR GLUCOSE-LEVELS IN NORMAL PEOPLE AND IN DIABETIC-PATIENTS [J].
SEN, DK ;
SARIN, GS .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1980, 64 (09) :693-695